Ion-selective microelectrode sensitive to neurotransmitter dopamine

被引:0
|
作者
Sun, YH [1 ]
Zheng, XX [1 ]
机构
[1] Zhejiang Univ, Dept Biomed Engn, Hangzhou 310027, Peoples R China
关键词
dopamine sensitive liquid membrane microelectrode; two-barrel;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper reported a novel two-barrel selective microelectrode sensitive to dopamine. The response properties or the microelectrode were studied.
引用
收藏
页码:411 / 412
页数:2
相关论文
共 50 条
  • [1] Study of ion-selective microelectrode sensitive to neurotransmitter dopamine
    Sun, YH
    Zheng, XX
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (08) : 993 - 996
  • [2] Studies of selective ion-sensitive microelectrode technique for the detection of neurotransmitter in vivo
    Zheng, XX
    Sun, YH
    [J]. PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 2862 - 2863
  • [3] AN ION-SELECTIVE MICROELECTRODE FOR BILE-SALTS
    KUNZE, LJ
    LINDENBAUM, S
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (08) : 947 - 954
  • [4] MEASUREMENT OF NITRATE GRADIENTS WITH AN ION-SELECTIVE MICROELECTRODE
    DEBEER, D
    SWEERTS, JPR
    [J]. ANALYTICA CHIMICA ACTA, 1989, 219 (02) : 351 - 356
  • [5] Microfabrication and characterization of an ion-selective microelectrode array platform
    Guenat, OT
    Dufour, JF
    van der Wal, PD
    Morf, WE
    de Rooij, NF
    Koudelka-Hep, M
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 105 (01): : 65 - 73
  • [6] Ion-selective microelectrode array for intracellular detection on chip
    Guenat, OT
    Wang, XJ
    Dufour, JF
    van der Wal, P
    Morf, WE
    de Rooij, NF
    Koudelka-Hep, M
    [J]. BOSTON TRANSDUCERS'03: DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2003, : 1063 - 1066
  • [7] Fabrication, calibration and evaluation of a phosphate ion-selective microelectrode
    Wang, John J.
    Bishop, Paul L.
    [J]. ENVIRONMENTAL POLLUTION, 2010, 158 (12) : 3612 - 3617
  • [8] DEVELOPMENT OF DOUBLE-BARRELED CALCIUM ION-SELECTIVE MICROELECTRODE
    Zhuang Yunlong
    Zhou Jianping and Qi Deyao(Department of Analytical Chemistry
    Shanghai University ofTechnology
    Shanghai)
    [J]. Chemical Research in Chinese Universities, 1986, (01) : 49 - 54
  • [9] Construction of an ion-selective microelectrode for the determination of sulfide in environmental biofilms
    Yu, T
    Bishop, PL
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 212 : 82 - IEC
  • [10] ION-SELECTIVE MICROELECTRODE ANALYSIS OF WHOLE PLAQUE AND PLAQUE FLUID
    CAREY, CM
    VOGEL, GL
    [J]. JOURNAL OF DENTAL RESEARCH, 1990, 69 : 135 - 135