Flow injection determination of methamidophos using online photo-oxidation and fluorimetric detection

被引:16
|
作者
Pérez-Ruiz, T [1 ]
Martínez-Lozano, C [1 ]
Tomás, V [1 ]
Martín, J [1 ]
机构
[1] Univ Murcia, Fac Chem, Dept Analyt Chem, E-30071 Murcia, Spain
关键词
methamidophos; photo-oxidation; flow injection; fluorimetric detection; food analysis;
D O I
10.1016/S0039-9140(01)00369-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A photochemical method for the determination of methamidophos using a flow injection system is proposed. The method is based on the rapid decomposition of methamidophos in the presence of peroxydisulphate upon irradiation with UV light. The phosphate generated in the photochemical process is made to react with molybdate in dilute nitric acid to form phosphomolybdic acid, which oxidises thiamine to thiochrome. The thiochrome can then be fluorimetrically monitored at 440 nm with excitation at 375 nm. The method shows a linear range between 14 and 1400 ng ml(-1) with a limit of detection of 1.7 ng ml(-1). The repeatability was 0.3% expressed as relative standard deviation (n = 10) and the reproducibility, studied on five different days, was +/- 3%. The sample throughput was 70 injections per h. The reliability of the method for routine analysis of water and vegetable samples is demonstrated. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:989 / 995
页数:7
相关论文
共 50 条
  • [31] PHOTO-OXIDATION OF WATER USING PRUSSIAN BLUE AS CATALYST
    CHRISTENSEN, PA
    HARRIMAN, A
    NETA, P
    RICHOUX, MC
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1985, 81 : 2461 - 2466
  • [32] Determination of L-phenylalanine in serum by flow-injection analysis using immobilized phenylalanine dehydrogenase and fluorimetric detection
    Kiba, N
    Itagaki, A
    Furusawa, M
    TALANTA, 1997, 44 (01) : 131 - 134
  • [33] Determination of aluminum in dialysates and human serum by flow injection analysis and liquid chromatography with fluorimetric detection
    Kokot, Z
    Pawlaczyk, J
    CHEMIA ANALITYCZNA, 1998, 43 (02): : 215 - 224
  • [35] Fast flow-injection fluorimetric determination of amiloride by using a solid sensing zone
    Domínguez-Vidal, A
    Ortega-Barrales, P
    Molina-Díaz, A
    TALANTA, 2002, 56 (06) : 1005 - 1013
  • [36] Successive Determination of Chromium (VI) and Total Chromium by FIA Using Photo-oxidation with Vacuum Ultraviolet
    Taguchi, Shigeru
    Fujii, Ayako
    Okoshi, Takashi
    Kuramitz, Hideki
    Hata, Noriko
    BUNSEKI KAGAKU, 2010, 59 (12) : 1133 - 1136
  • [37] DETERMINATION OF MANGANESE IN SEAWATER USING FLOW-INJECTION ANALYSIS WITH ONLINE PRECONCENTRATION AND SPECTROPHOTOMETRIC DETECTION
    RESING, JA
    MOTTL, MJ
    ANALYTICAL CHEMISTRY, 1992, 64 (22) : 2682 - 2687
  • [38] Flow injection catalytically kinetic fluorimetric determination of trace ruthenium
    Wang, Ketai
    Chen, Xingguo
    Hu, Zhide
    Guijinshu/Precious Metals, 19 (03): : 40 - 42
  • [39] Flow-injection fluorimetric determination of thiamine in pharmaceutical preparations
    Viñas, P
    López-Erroz, C
    Cerdán, FJ
    Campillo, N
    Hernández-Córdoba, M
    MIKROCHIMICA ACTA, 2000, 134 (1-2) : 83 - 87
  • [40] Rapid and selective determination of ammonium by fluorimetric flow injection analysis
    H. Mana
    U. Spohn
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 825 - 829