Flow injection determination of methamidophos using online photo-oxidation and fluorimetric detection

被引:16
|
作者
Pérez-Ruiz, T [1 ]
Martínez-Lozano, C [1 ]
Tomás, V [1 ]
Martín, J [1 ]
机构
[1] Univ Murcia, Fac Chem, Dept Analyt Chem, E-30071 Murcia, Spain
关键词
methamidophos; photo-oxidation; flow injection; fluorimetric detection; food analysis;
D O I
10.1016/S0039-9140(01)00369-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A photochemical method for the determination of methamidophos using a flow injection system is proposed. The method is based on the rapid decomposition of methamidophos in the presence of peroxydisulphate upon irradiation with UV light. The phosphate generated in the photochemical process is made to react with molybdate in dilute nitric acid to form phosphomolybdic acid, which oxidises thiamine to thiochrome. The thiochrome can then be fluorimetrically monitored at 440 nm with excitation at 375 nm. The method shows a linear range between 14 and 1400 ng ml(-1) with a limit of detection of 1.7 ng ml(-1). The repeatability was 0.3% expressed as relative standard deviation (n = 10) and the reproducibility, studied on five different days, was +/- 3%. The sample throughput was 70 injections per h. The reliability of the method for routine analysis of water and vegetable samples is demonstrated. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:989 / 995
页数:7
相关论文
共 50 条
  • [21] Flow injection fluorimetric determination of β-estradiol using a molecularly imprinted polymer
    Bravo, JC
    Fernández, P
    Durand, JS
    ANALYST, 2005, 130 (10) : 1404 - 1409
  • [22] AUTOMATED FLUORIMETRIC DETERMINATION OF CREATINE USING FLOW-INJECTION ANALYSIS
    MASOOM, M
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 1989, 11 (01): : 32 - 36
  • [23] Ethanol determination using pressure mobilization and free solution capillary electrophoresis by photo-oxidation assisted ultraviolet detection
    Oliver, James D.
    Gaborieau, Marianne
    Castignolles, Patrice
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1348 : 150 - 157
  • [24] FLUORIMETRIC DETERMINATION OF AFLATOXINS BY FLOW-INJECTION ANALYSIS
    LAZARO, F
    DECASTRO, MDL
    VALCARCEL, M
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 332 (07): : 809 - 812
  • [25] Flow-injection fluorimetric determination of nabam and metham
    PerezRuiz, T
    MartinezLozano, C
    Tomas, V
    Casajus, R
    TALANTA, 1996, 43 (02) : 193 - 198
  • [26] Determination of lead with GFAAS using online flow injection
    Department of Chemistry, Sichuan Teacher's University, Nanchong 637002, China
    Guang Pu Xue Yu Guang Pu Fen Xi, 2007, 6 (1243-1245):
  • [27] Determination of lead with GFAAS using online flow injection
    Chen Zhong-lan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27 (06) : 1243 - 1245
  • [28] STUDY OF PHOTO-OXIDATION OF ROSANILINE - KINETIC DETERMINATION OF FE(III)
    RUIZ, TP
    LOZANO, CM
    MARTINEZ, VT
    DELVALLE, JB
    ANALES DE QUIMICA SERIE B-QUIMICA INORGANICA Y QUIMICA ANALYTICA, 1988, 84 (01): : 84 - 88
  • [29] PHOTOELECTROCHEMISTRY OF GAAS - DETERMINATION OF THE YIELD OF FERROCYANIDE PHOTO-OXIDATION BY AMPEROMETRY
    SAVADOGO, O
    DESCHANVRES, A
    REVUE DE CHIMIE MINERALE, 1983, 20 (02): : 274 - 282
  • [30] Flavin-mediated photo-oxidation for the detection of mitochondrial flavins
    Lee, Dong-Nam
    Kim, Eunjin
    Lee, Jae Hong
    Kim, Jong Seung
    Kang, Chulhun
    Hong, Jong-In
    CHEMICAL COMMUNICATIONS, 2016, 52 (92) : 13487 - 13490