Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode

被引:9
|
作者
Stankovic, Anamarija [1 ]
Kajinic, Zana [1 ]
Turkalj, Jelena Vesligaj [2 ]
Romic, Zeljka [2 ]
Sikiric, Maja Dutour [3 ]
Asserghine, Abdelilah [4 ]
Nagy, Geza [4 ,5 ]
Medvidovic-Kosanovic, Martina [1 ]
机构
[1] Univ Osijek, Dept Chem, Ul Cara Hadrijana 8A, HR-31000 Osijek, Croatia
[2] Vodovod, Poljski Put 1, HR-31000 Osijek, Croatia
[3] Rudjer Boskovic Inst, Bijenicka Ul 54, HR-10000 Zagreb, Croatia
[4] Univ Pecs, Fac Sci, Dept Gen & Phys Chem, 7624,Ifjusag U 6, Pecs, Hungary
[5] Univ Pecs, Janos Szentagothai Res Ctr, 7624,Ifjusag U 20, Pecs, Hungary
关键词
groundwater; arsenic detection; modified glassy carbon electrode; SECM; EIS; ELECTROCHEMICAL DETECTION; DRINKING-WATER; NATURAL-WATERS; HEAVY-METAL; GROUNDWATER; SPECIATION; ELECTROANALYSIS; CONTAMINATION; PARTICLES; CANCER;
D O I
10.1002/elan.201900666
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, glassy carbon electrode modified with nano gold-crystal violet film has been used to detect arsenite (As (III)) in a model system and in groundwater samples. The modified electrode was characterized by scanning electrochemical microscopy (SECM) and electrochemical impedance spectroscopy (EIS). Using voltammetric measuring technique, linear response was obtained in a concentration range of 2.0-22.0 mu M. The arsenite concentrations in groundwater samples varied between 2.4 mu M to 4.8 mu M. The sensitivity of the modified electrode for As (III) detection was 5.6 mu A/mu M cm(2) and 0.8 mu M concentration was found as lower limit of detection (LOD). The accuracy of the method was checked with standard method anodic stripping voltammetry (ASV). Groundwater samples were characterized with dynamic (DLS) and electrophoretic (ELS) light scattering measurements which have shown that particles present in different samples differ in size distribution and zeta potential which did not interfere with As (III) detection.
引用
收藏
页码:1043 / 1051
页数:9
相关论文
共 50 条
  • [31] Voltammetric Determination of Dopamine in the Presence of Caffeine Using a Modified Glassy Carbon Electrode
    [J]. Surface Engineering and Applied Electrochemistry, 2023, 59 : 634 - 643
  • [32] Voltammetric determination of catechol and hydroquinone at poly (niacinamide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Ganesh, P. S.
    Rani, T. Shobha
    Reddy, G. Venkata
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 505 - 511
  • [33] Voltammetric determination of ascorbic acid with zinc oxide modified glassy carbon electrode
    Nadia Ait Ahmed
    Houa Hammache
    Marielle Eyraud
    Carine Chassigneux
    Florence Vacandio
    Philippe Knauth
    Laid Makhloufi
    Nour-eddine Gabouze
    [J]. Journal of the Iranian Chemical Society, 2019, 16 : 1957 - 1963
  • [34] Voltammetric determination of bisoprolol on a glassy carbon electrode modified by poly(arylene phthalide)
    R. A. Zil’berg
    Yu. A. Yarkaeva
    A. V. Sidel’nikov
    V. N. Maistrenko
    V. A. Kraikin
    N. G. Gileva
    [J]. Journal of Analytical Chemistry, 2016, 71 : 926 - 931
  • [35] Voltammetric Determination of Flunixin on Molecularly Imprinted Polypyrrole Modified Glassy Carbon Electrode
    Radi, Abd-Elgawad
    Abd El-Ghany, Nadia
    Wahdan, Tarek
    [J]. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2016, 2016
  • [36] Voltammetric determination of ascorbic acid with zinc oxide modified glassy carbon electrode
    Ahmed, Nadia Ait
    Hammache, Houa
    Eyraud, Marielle
    Chassigneux, Carine
    Vacandio, Florence
    Knauth, Philippe
    Makhloufi, Laid
    Gabouze, Nour-eddine
    [J]. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2019, 16 (09) : 1957 - 1963
  • [37] Voltammetric Response of Epinephrine at Carbon Nanotube Modified Glassy Carbon Electrode and Activated Glassy Carbon Electrode
    WANG Juan~1
    2. Department of Environmental Engineer
    [J]. Wuhan University Journal of Natural Sciences, 2005, (05) : 913 - 918
  • [38] Simultaneous voltammetric determination of tramadol and acetaminophen using carbon nanoparticles modified glassy carbon electrode
    Ghorbani-Bidkorbeh, Fatemeh
    Shahrokhian, Saeed
    Mohammadi, Ali
    Dinarvand, Rassoul
    [J]. ELECTROCHIMICA ACTA, 2010, 55 (08) : 2752 - 2759
  • [39] Voltammetric Determination of Sulfonamides with a Modified Glassy Carbon Electrode Using Carboxyl Multiwalled Carbon Nanotubes
    He, Bao-Shan
    Chen, Wen-Bo
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (12) : 2216 - 2225
  • [40] Voltammetric determination of nicotinic acid by glassy-carbon electrode modified with multiwall carbon nanotubes
    Sh. Lü
    [J]. Russian Journal of Electrochemistry, 2006, 42 : 163 - 166