Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode

被引:9
|
作者
Stankovic, Anamarija [1 ]
Kajinic, Zana [1 ]
Turkalj, Jelena Vesligaj [2 ]
Romic, Zeljka [2 ]
Sikiric, Maja Dutour [3 ]
Asserghine, Abdelilah [4 ]
Nagy, Geza [4 ,5 ]
Medvidovic-Kosanovic, Martina [1 ]
机构
[1] Univ Osijek, Dept Chem, Ul Cara Hadrijana 8A, HR-31000 Osijek, Croatia
[2] Vodovod, Poljski Put 1, HR-31000 Osijek, Croatia
[3] Rudjer Boskovic Inst, Bijenicka Ul 54, HR-10000 Zagreb, Croatia
[4] Univ Pecs, Fac Sci, Dept Gen & Phys Chem, 7624,Ifjusag U 6, Pecs, Hungary
[5] Univ Pecs, Janos Szentagothai Res Ctr, 7624,Ifjusag U 20, Pecs, Hungary
关键词
groundwater; arsenic detection; modified glassy carbon electrode; SECM; EIS; ELECTROCHEMICAL DETECTION; DRINKING-WATER; NATURAL-WATERS; HEAVY-METAL; GROUNDWATER; SPECIATION; ELECTROANALYSIS; CONTAMINATION; PARTICLES; CANCER;
D O I
10.1002/elan.201900666
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, glassy carbon electrode modified with nano gold-crystal violet film has been used to detect arsenite (As (III)) in a model system and in groundwater samples. The modified electrode was characterized by scanning electrochemical microscopy (SECM) and electrochemical impedance spectroscopy (EIS). Using voltammetric measuring technique, linear response was obtained in a concentration range of 2.0-22.0 mu M. The arsenite concentrations in groundwater samples varied between 2.4 mu M to 4.8 mu M. The sensitivity of the modified electrode for As (III) detection was 5.6 mu A/mu M cm(2) and 0.8 mu M concentration was found as lower limit of detection (LOD). The accuracy of the method was checked with standard method anodic stripping voltammetry (ASV). Groundwater samples were characterized with dynamic (DLS) and electrophoretic (ELS) light scattering measurements which have shown that particles present in different samples differ in size distribution and zeta potential which did not interfere with As (III) detection.
引用
收藏
页码:1043 / 1051
页数:9
相关论文
共 50 条
  • [21] Voltammetric determination of ofloxacin by using a laser-modified carbon glassy electrode
    Feng, Limin
    Xue, Qiang
    Liu, Fei
    Cao, Qipu
    Feng, Jijun
    Yang, Liang
    Zhang, Fuling
    [J]. MICROCHIMICA ACTA, 2020, 187 (01)
  • [22] Voltammetric determination of ofloxacin by using a laser-modified carbon glassy electrode
    Limin Feng
    Qiang Xue
    Fei Liu
    Qipu Cao
    Jijun Feng
    Liang Yang
    Fuling Zhang
    [J]. Microchimica Acta, 2020, 187
  • [23] Voltammetric determination of catechol and hydroquinone at poly (murexide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Rani, T. Shobha
    Ganesh, P. S.
    Raj, Y. Paul
    [J]. MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 98 : 746 - 752
  • [24] Graphene nanocomposite modified glassy carbon electrode for voltammetric determination of the antipsychotic quetiapine
    Biljana Nigović
    Ana Mornar
    Miranda Sertić
    [J]. Microchimica Acta, 2016, 183 : 1459 - 1467
  • [25] Voltammetric Determination of Dopamine in the Presence of Caffeine Using a Modified Glassy Carbon Electrode
    Ebrahimi, Maryam
    Beitollahi, Hadi
    [J]. SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2023, 59 (05) : 634 - 643
  • [26] Voltammetric Determination of Anthracene Using a DNA-Modified Glassy Carbon Electrode
    Blaskova, Marta
    Hajkova, Andrea
    Vyskocil, Vlastimil
    [J]. CHEMICKE LISTY, 2015, 109 (03): : 235 - 240
  • [27] Voltammetric determination of bisoprolol on a glassy carbon electrode modified by poly(arylene phthalide)
    Zil'berg, R. A.
    Yarkaeva, Yu. A.
    Sidel'nikov, A. V.
    Maistrenko, V. N.
    Kraikin, V. A.
    Gileva, N. G.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (09) : 926 - 931
  • [28] Graphene nanocomposite modified glassy carbon electrode for voltammetric determination of the antipsychotic quetiapine
    Nigovic, Biljana
    Mornar, Ana
    Sertic, Miranda
    [J]. MICROCHIMICA ACTA, 2016, 183 (04) : 1459 - 1467
  • [29] Stripping voltammetric determination of Epinephrine applying sulfacetamide modified glassy carbon electrode
    Ahmed, T. A.
    Ghandour, M. A.
    Khalil, M. M.
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (04): : 3143 - 3156
  • [30] Voltammetric determination of dopamine using modified glassy carbon electrode by electrografting of catechol
    Pourghobadi, Zeinab
    Neamatollahi, Davood
    [J]. JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2017, 82 (09) : 1053 - 1061