Performance of a real time selenium based x-ray detector for fluoroscopy

被引:24
|
作者
Choquette, M [1 ]
Demers, Y [1 ]
Shukri, Z [1 ]
Tousignant, O [1 ]
Aoki, K [1 ]
Honda, M [1 ]
Takahashi, A [1 ]
Tsukamoto, A [1 ]
机构
[1] ANRAD Corp, St Laurent, PQ H4R 2P1, Canada
关键词
selenium; flat-panel detector; TFT; fluoroscopy; real-time; dynamic; direct conversion; x-ray detector;
D O I
10.1117/12.430873
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As amorphous selenium based flat panel detectors gain more interest for direct, real-time x-ray imaging, we report in this paper the performance of such a detector by ANRAD Corporation. This new detector is based on a 1536 x 1536 array of amorphous silicon TFT pixels coupled with a 1000 mum selenium converter biased at 10 V/mum. Each 150 mum x 150 mum pixel is made of a thin film transistor (TFT), a storage capacitor and a collecting electrode having a geometrical fill factor of 77% and an effective fill factor of nearby 100%. New TFT architecture and high speed electronics allow operation of this new detector under a large range of conditions from low dose fluoroscopy (few muR/frame) to DR and it supports frame rates from single shot to 60 fps. Image lag following x-ray excitation was measured to be very low. Key imaging parameters for this real time x-ray detection system such as: detective quantum efficiency (DQE), signal to noise ratio (SNR) and modulation transfer function (MTF) were measured. These results together with frames extracted from a low dose fluoroscopy sequence and an anthropomorphic phantom image will be presented. The measurements show that the dynamic performance of this new detector is very well suited for real time imaging in fluoroscopic and/or cardiac applications.
引用
收藏
页码:501 / 508
页数:8
相关论文
共 50 条
  • [21] Performance of mobile digital X-ray fluoroscopy using a novel flat panel detector for intraoperative use
    Jeong, Chang-Won
    Ryu, Jong-Hyun
    Joo, Su-Chong
    Jun, Hong-Young
    Heo, Dong-Woon
    Lee, Jinseok
    Kim, Kyong-Woo
    Yoon, Kwon-Ha
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (03) : 365 - 372
  • [22] Noise optimization of an active pixel sensor for real-time digital X-ray fluoroscopy
    Izadi, A. H.
    Karim, K. S.
    NOISE AND FLUCTUATIONS IN CIRCUITS, DEVICES, AND MATERIALS, 2007, 6600
  • [23] New CsI:Na-selenium X-ray detector
    Seck, DW
    Choi, JY
    Kang, SS
    Jang, GW
    Mun, CW
    Nam, SH
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 633 - 638
  • [24] X-RAY TELEVISION FLUOROSCOPY
    HALL, HT
    FONDERIE-FRANCE, 1968, (267): : 195 - &
  • [25] Amorphous-Selenium-Based Three-Terminal X-Ray Detector With a Gate
    Wang, Kai
    Chen, Feng
    Allec, Nicholas
    Yuan, Fang
    Belev, George
    Kasap, Safa
    Karim, Karim S.
    IEEE ELECTRON DEVICE LETTERS, 2011, 32 (06) : 782 - 784
  • [26] X-ray detector based on GaN
    Duboz, J. Y.
    Frayssinet, E.
    Chenot, Sebastien
    Reverchon, J. L.
    Idir, M.
    GALLIUM NITRIDE MATERIALS AND DEVICES VIII, 2013, 8625
  • [27] Image quality evaluation of flat panel detector binning in X-ray fluoroscopy
    Srinivas, Y
    Wilson, DL
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 177 - 180
  • [28] Adaptive Digital X-Ray Detector for High Sensitivity Medical Fluoroscopy Imaging
    Smith, Joseph T.
    Forsythe, Eric W.
    Allee, David R.
    Christen, Jennifer Blain
    2015 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2015, : 604 - 607
  • [29] Characterization of detector scintillator effect on interventional device visualization in x-ray fluoroscopy
    Jiang, Yuhao
    Wilson, David L.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1850 - 1853
  • [30] Experimental optimization of detector pixel size for stent visualization in x-ray fluoroscopy
    Jiang, YH
    Wilson, DL
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 552 - 555