Characterization of three solid state dosimetry systems for use in high energy photon dosimetry audits in radiotherapy

被引:47
|
作者
Wesolowska, Paulina Elzbieta [1 ]
Cole, Andrew [1 ]
Santos, Tania [1 ]
Bokulic, Tomislav [1 ]
Kazantsev, Pavel [1 ]
Izewska, Joanna [1 ]
机构
[1] IAEA, Sect Dosimetry & Med Radiat Phys, Vienna, Austria
关键词
TLD; OSLD; RPLD; Quality audits in radiotherapy; OPTICALLY STIMULATED LUMINESCENCE; TLD; OSL; BEAMS;
D O I
10.1016/j.radmeas.2017.04.017
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The IAEA Dosimetry Laboratory (DOL) aims to improve the accuracy of clinical dosimetry in hospitals world-wide by providing independent remote audits for high energy photon beams. A thermoluminescent dosimetry (TLD) system has been used by the DOL to provide audit services for over 47 years. Two additional systems: an optically stimulated luminescent dosimetry (OSLD) system and a radiophoto luminescent dosimetry (RPLD) system underwent a commissioning process. The systems' parameters, reading methodology and the dosimetric characteristics were investigated and compared. The read-out procedure for each system was established and optimized. Dosimetric characteristics such as reproducibility, signal fading with time after irradiation, signal per dose dependence and energy response were investigated. Additional tests to check signal depletion per readout and individual sensitivities of dosimeters were performed for RPLDs and OSLDs and also reading position dependence for the RPLD system was checked. The reproducibility of 4 readings of one dosimeter is 0.48% for TLDs, 0.16% for OSLDs and 0.15% for RPLDs. The fading effect after 100 days was 4% for TLD, 2% for OSLD and 0.4% for RPLD. Energy response of TLDs and RPLDs is comparable, higher corrections were found for OSLDs. The RPLD dose-response is sub linear whereas TLD and OSLD response is supra-linear at the dose range under study (1-4 Gy). The TLD reading procedure is destructive but OSLDs and RPLDs can be read repeatedly and the signal depletion per reading is 0.036% for OSLDs and 0.017% for RPLDs. The sensitivity correction factors for RPLDs and OSLDs were determined with the standard deviation in response of 1000 dosimeters of 2.2% for OSLD and 0.9% for RPLD. The combined standard uncertainties (k=1) are 1.60% for TLDs, 1.46% for OSLDs and 1.51% for RPLDs. All three systems can be successfully used for auditing purposes if corrections for all described effects are applied. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:556 / 562
页数:7
相关论文
共 50 条
  • [21] Comparative dosimetry in narrow high-energy photon beams
    Westermark, M
    Arndt, J
    Nilsson, B
    Brahme, A
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (03): : 685 - 702
  • [22] Feasibility study of glass dosimeter postal dosimetry audit of high-energy radiotherapy photon beams
    Mizuno, Hideyuki
    Kanai, Tatsuaki
    Kusano, Yohsuke
    Ko, Susumu
    Ono, Mari
    Fukumura, Akifumi
    Abe, Kyoko
    Nishizawa, Kanae
    Shimbo, Munefumi
    Sakata, Suoh
    Ishikura, Satoshi
    Ikeda, Hiroshi
    RADIOTHERAPY AND ONCOLOGY, 2008, 86 (02) : 258 - 263
  • [23] DOSIMETRY OF LARGE WEDGED HIGH-ENERGY PHOTON BEAMS
    PODGORSAK, MB
    KUBSAD, SS
    PALIWAL, BR
    MEDICAL PHYSICS, 1993, 20 (02) : 369 - 373
  • [24] HIGH-ENERGY PHOTON AND ELECTRON DOSIMETRY WITH TLD MATERIALS
    LAHTINEN, T
    KOSUNEN, A
    PUURUNEN, H
    VAINIO, P
    MEDICAL PHYSICS, 1984, 11 (03) : 384 - 384
  • [25] ESR ALANINE DOSIMETRY OF HIGH-ENERGY ELECTRONS IN RADIOTHERAPY
    CHU, S
    WIESER, A
    FEIST, H
    REGULLA, DF
    APPLIED RADIATION AND ISOTOPES, 1989, 40 (10-12) : 993 - 996
  • [26] Response characterization of ammonium tartrate solid state pellets for ESR dosimetry with radiotherapeutic photon and electron beams
    Bartolotta, A
    D'Oca, MC
    Brai, M
    Caputo, V
    De Caro, V
    Giannola, LI
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 461 - 471
  • [27] ESR/alanine dosimetry of high-energy electrons in radiotherapy
    Chu, S.
    Wieser, A.
    Feist, H.
    Regulla, D.F.
    International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes, 1989, 40 (10-12): : 993 - 996
  • [28] SOLID-STATE NUCLEAR TRACK DETECTORS IN HIGH-ENERGY PARTICLE DOSIMETRY
    SPURNY, F
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 509 - 512
  • [29] USE OF IONIZATION CHAMBERS IN HIGH ENERGY ELECTRON DOSIMETRY
    KARTHA, M
    MACDONAL.JC
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 134 - &
  • [30] Evaluation of optically stimulated luminescence (OSL) dosimetry for high-energy photon and electron beam measurements in radiotherapy
    Yukihara, E.
    Mardirossian, G.
    Ahmad, S.
    Mirzasadeghi, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 2100 - 2100