Characterization of three solid state dosimetry systems for use in high energy photon dosimetry audits in radiotherapy

被引:47
|
作者
Wesolowska, Paulina Elzbieta [1 ]
Cole, Andrew [1 ]
Santos, Tania [1 ]
Bokulic, Tomislav [1 ]
Kazantsev, Pavel [1 ]
Izewska, Joanna [1 ]
机构
[1] IAEA, Sect Dosimetry & Med Radiat Phys, Vienna, Austria
关键词
TLD; OSLD; RPLD; Quality audits in radiotherapy; OPTICALLY STIMULATED LUMINESCENCE; TLD; OSL; BEAMS;
D O I
10.1016/j.radmeas.2017.04.017
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The IAEA Dosimetry Laboratory (DOL) aims to improve the accuracy of clinical dosimetry in hospitals world-wide by providing independent remote audits for high energy photon beams. A thermoluminescent dosimetry (TLD) system has been used by the DOL to provide audit services for over 47 years. Two additional systems: an optically stimulated luminescent dosimetry (OSLD) system and a radiophoto luminescent dosimetry (RPLD) system underwent a commissioning process. The systems' parameters, reading methodology and the dosimetric characteristics were investigated and compared. The read-out procedure for each system was established and optimized. Dosimetric characteristics such as reproducibility, signal fading with time after irradiation, signal per dose dependence and energy response were investigated. Additional tests to check signal depletion per readout and individual sensitivities of dosimeters were performed for RPLDs and OSLDs and also reading position dependence for the RPLD system was checked. The reproducibility of 4 readings of one dosimeter is 0.48% for TLDs, 0.16% for OSLDs and 0.15% for RPLDs. The fading effect after 100 days was 4% for TLD, 2% for OSLD and 0.4% for RPLD. Energy response of TLDs and RPLDs is comparable, higher corrections were found for OSLDs. The RPLD dose-response is sub linear whereas TLD and OSLD response is supra-linear at the dose range under study (1-4 Gy). The TLD reading procedure is destructive but OSLDs and RPLDs can be read repeatedly and the signal depletion per reading is 0.036% for OSLDs and 0.017% for RPLDs. The sensitivity correction factors for RPLDs and OSLDs were determined with the standard deviation in response of 1000 dosimeters of 2.2% for OSLD and 0.9% for RPLD. The combined standard uncertainties (k=1) are 1.60% for TLDs, 1.46% for OSLDs and 1.51% for RPLDs. All three systems can be successfully used for auditing purposes if corrections for all described effects are applied. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:556 / 562
页数:7
相关论文
共 50 条
  • [1] SURVEY OF SOLID STATE DOSIMETRY SYSTEMS
    FOWLER, JF
    BRITISH JOURNAL OF RADIOLOGY, 1963, 36 (430): : 778 - 778
  • [2] Dosimetry quality audit of high energy photon beams in greek radiotherapy centers
    Hourdakis, Constantine J.
    Boziari, A.
    RADIOTHERAPY AND ONCOLOGY, 2008, 87 (01) : 132 - 141
  • [3] Comparison of high-energy photon and electron dosimetry for various dosimetry protocols
    Araki, F
    Kubo, HD
    MEDICAL PHYSICS, 2002, 29 (05) : 857 - 868
  • [4] Feasibility study for high energy photon small beam dosimetry audits using OSL and RPL dosimeters
    Bokulic, T.
    Kazantsev, P.
    Wesolowska, P.
    Lechner, W.
    Izewska, J.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : E556 - E556
  • [5] TLD and OSLD dosimetry systems for remote audits of radiotherapy external beam calibration
    Alvarez, P.
    Kry, S. F.
    Stingo, F.
    Followill, D.
    RADIATION MEASUREMENTS, 2017, 106 : 412 - 415
  • [6] Characterization of a commercial PIN diode for radiotherapy photon beam dosimetry
    Silva, Iandra T.
    Pieri, Karen
    Albino, Lucas D.
    Fontana, Thiago S.
    dos Santos, Matheus F.
    Roesler, Ernesto
    Oliveira, Charles N. P.
    Asfora, Viviane K.
    Goncalves, Josemary A. C.
    Khoury, Helen J.
    Bueno, Carmen C.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 221
  • [7] Characterization of phenolic pellets for ESR dosimetry in photon beam radiotherapy
    Salvatore Gallo
    Giuseppina Iacoviello
    Salvatore Panzeca
    Ivan Veronese
    Antonio Bartolotta
    Daniele Dondi
    Anna Maria Gueli
    Gianfranco Loi
    Anna Longo
    Eleonora Mones
    Maurizio Marrale
    Radiation and Environmental Biophysics, 2017, 56 : 471 - 480
  • [8] Characterization of phenolic pellets for ESR dosimetry in photon beam radiotherapy
    Gallo, Salvatore
    Iacoviello, Giuseppina
    Panzeca, Salvatore
    Veronese, Ivan
    Bartolotta, Antonio
    Dondi, Daniele
    Gueli, Anna Maria
    Loi, Gianfranco
    Longo, Anna
    Mones, Eleonora
    Marrale, Maurizio
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2017, 56 (04) : 471 - 480
  • [9] An Evaluation of Solid Phantoms for the Dosimetry of Low Energy Photon Beams
    Hill, R.
    Kuncic, Z.
    Baldock, C.
    MEDICAL PHYSICS, 2008, 35 (06) : 2794 - +
  • [10] HIGH-ENERGY PHOTON DOSIMETRY IN FINITE ABSORBERS
    STAUBER, MC
    BRANDT, W
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (03): : 270 - 270