Human Authentication Based on ECG Waves Using Radon Transform

被引:0
|
作者
Hegde, Chetana [1 ]
Prabhu, H. Rahul [2 ]
Sagar, D. S. [2 ]
Shenoy, P. Deepa [2 ]
Venugopal, K. R. [2 ]
Patnaik, L. M. [3 ]
机构
[1] Bangalore Univ, Bangalore 560001, Karnataka, India
[2] Bangalore Univ, UVCE, Dept CSE, Bangalore 560001, Karnataka, India
[3] DIAT, Pune, Maharashtra, India
关键词
FAR; FRR; Pairwise Distance; Pre-processing; Radon Transform;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Automated security is one of the major concerns of modern times. Secure and reliable authentication systems are in great demand. A biometric trait like electrocardiogram (ECG) of a person is unique and secure. In this paper, we propose a human authentication system based on ECG waves considering a plotted ECG wave signal as an image. The Radon Transform is applied on the preprocessed ECG image to get a radon image consisting of projections for theta varying from 0 degrees to 180 degrees. The pairwise distance between the columns of Radon image is computed to get a feature vector. Correlation Coefficient between feature vector stored in the database and that of input image is computed to check the authenticity of a person. Then the confusion matrix is generated to find False Acceptance Ratio (FAR) and False Rejection Ratio (FRR). This methodology of authentication is tested on ECG wave data set of 105 individuals taken from Physionet QT Database. The proposed authentication system is found to have FAR of about 3.19% and FRR of about 0.128%. The overall accuracy of the system is found to be 99.85%.
引用
收藏
页码:197 / +
页数:3
相关论文
共 50 条
  • [41] Image retrieval technique using the clustering based on rearranged radon transform
    An, Youngeun
    Lee, Jimin
    Park, Jongan
    [J]. MULTIMEDIA TOOLS AND APPLICATIONS, 2016, 75 (20) : 12983 - 12997
  • [42] Application of the wavelet based Radon transform
    Deans, SR
    Gangadharan, D
    [J]. EXPLOITING NEW IMAGE SOURCES AND SENSORS, 26TH AIPR WORKSHOP, 1998, 3240 : 191 - 199
  • [43] Face recognition based on Radon transform
    Yang, Meixia
    Cao, Zhuming
    [J]. PROCEEDINGS OF THE 2015 4TH NATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS AND COMPUTER ENGINEERING ( NCEECE 2015), 2016, 47 : 296 - 300
  • [44] Image retrieval technique using the clustering based on rearranged radon transform
    Youngeun An
    Jimin Lee
    Jongan Park
    [J]. Multimedia Tools and Applications, 2016, 75 : 12983 - 12997
  • [45] Automated Pleural Line Detection Based on Radon Transform Using Ultrasound
    Chen, Jiangang
    Li, Jiawei
    He, Chao
    Li, Wenfang
    Li, Qingli
    [J]. ULTRASONIC IMAGING, 2021, 43 (01) : 19 - 28
  • [46] Features based image registration using cross correlation and Radon transform
    Chelbi, S.
    Mekhmoukh, A.
    [J]. ALEXANDRIA ENGINEERING JOURNAL, 2018, 57 (04) : 2313 - 2318
  • [47] Age classification using Radon transform and entropy based scaling SVM
    Zhou, Huiyu
    Miller, Paul
    Zhang, Jianguo
    [J]. PROCEEDINGS OF THE BRITISH MACHINE VISION CONFERENCE 2011, 2011,
  • [48] ECG Biometric Authentication Using a Dynamical Model
    Sarkar, Abhijit
    Abbott, A. Lynn
    Doerzaph, Zachary
    [J]. 2015 IEEE 7TH INTERNATIONAL CONFERENCE ON BIOMETRICS THEORY, APPLICATIONS AND SYSTEMS (BTAS 2015), 2015,
  • [49] ECG-BASED CONTINUOUS AUTHENTICATION SYSTEM USING ADAPTIVE STRING MATCHING
    Coutinho, David Pereira
    Fred, Ana L. N.
    Figueiredo, Mario A. T.
    [J]. BIOSIGNALS 2011, 2011, : 354 - +
  • [50] Biometric Authentication System Based on Electrocardiogram (ECG)
    Khan, Muhammad Umar
    Aziz, Sumair
    Iqtidar, Khushbakht
    Saud, Abdullah
    Azhar, Zohaib
    [J]. 2019 13TH INTERNATIONAL CONFERENCE ON MATHEMATICS, ACTUARIAL SCIENCE, COMPUTER SCIENCE AND STATISTICS (MACS-13), 2019,