Human Authentication Based on ECG Waves Using Radon Transform

被引:0
|
作者
Hegde, Chetana [1 ]
Prabhu, H. Rahul [2 ]
Sagar, D. S. [2 ]
Shenoy, P. Deepa [2 ]
Venugopal, K. R. [2 ]
Patnaik, L. M. [3 ]
机构
[1] Bangalore Univ, Bangalore 560001, Karnataka, India
[2] Bangalore Univ, UVCE, Dept CSE, Bangalore 560001, Karnataka, India
[3] DIAT, Pune, Maharashtra, India
关键词
FAR; FRR; Pairwise Distance; Pre-processing; Radon Transform;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Automated security is one of the major concerns of modern times. Secure and reliable authentication systems are in great demand. A biometric trait like electrocardiogram (ECG) of a person is unique and secure. In this paper, we propose a human authentication system based on ECG waves considering a plotted ECG wave signal as an image. The Radon Transform is applied on the preprocessed ECG image to get a radon image consisting of projections for theta varying from 0 degrees to 180 degrees. The pairwise distance between the columns of Radon image is computed to get a feature vector. Correlation Coefficient between feature vector stored in the database and that of input image is computed to check the authenticity of a person. Then the confusion matrix is generated to find False Acceptance Ratio (FAR) and False Rejection Ratio (FRR). This methodology of authentication is tested on ECG wave data set of 105 individuals taken from Physionet QT Database. The proposed authentication system is found to have FAR of about 3.19% and FRR of about 0.128%. The overall accuracy of the system is found to be 99.85%.
引用
收藏
页码:197 / +
页数:3
相关论文
共 50 条
  • [31] Inversion of the elliptical Radon transform arising in migration imaging using the regular Radon transform
    Moon, Sunghwan
    Heo, Joonghyeok
    [J]. JOURNAL OF MATHEMATICAL ANALYSIS AND APPLICATIONS, 2016, 436 (01) : 138 - 148
  • [32] FEATURE EXTRACTION BASED ON WAVELET TRANSFORM USING ECG SIGNAL
    Palacios-Enriquez, A.
    Ponomaryov, V.
    [J]. 2013 INTERNATIONAL KHARKOV SYMPOSIUM ON PHYSICS AND ENGINEERING OF MICROWAVES, MILLIMETER AND SUBMILLIMETER WAVES (MSMW), 2013, : 632 - 634
  • [33] Human Recognition using Discrete Cosine Transform and Discriminant Analysis of ECG
    Srivastva, Ranjeet
    Singh, Yogendra Narain
    [J]. 2017 FOURTH INTERNATIONAL CONFERENCE ON IMAGE INFORMATION PROCESSING (ICIIP), 2017, : 368 - 372
  • [34] The Radon transform inversion using moments
    Mnatsakanov, Robert M.
    Li, Shengqiao
    [J]. STATISTICS & PROBABILITY LETTERS, 2013, 83 (03) : 936 - 942
  • [35] ECG-based Human Authentication using High-level Spectro-temporal Signal Features
    Abdeldayem, Sara S.
    Bourlai, Thirimachos
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON BIG DATA (BIG DATA), 2018, : 4984 - 4993
  • [36] Parameter Recovery Using Radon Transform
    Komal, Komal
    Bhattacharjee, Nandita
    Albrecht, David
    Srinivasan, Bala
    [J]. 16TH INTERNATIONAL CONFERENCE ON ADVANCES IN MOBILE COMPUTING AND MULTIMEDIA (MOMM 2018), 2014, : 34 - 43
  • [37] FINGERPRINT IDENTIFICATION USING RADON TRANSFORM
    Haddad, Zehira
    Beghdadi, Azeddine
    Serir, Amina
    Mokraoui, Anissa
    [J]. 2008 FIRST INTERNATIONAL WORKSHOPS ON IMAGE PROCESSING THEORY, TOOLS AND APPLICATIONS (IPTA), 2008, : 401 - +
  • [38] Face Recognition Using Radon Transform
    Albu, Razvan-Daniel
    [J]. 2015 IEEE 21ST INTERNATIONAL SYMPOSIUM FOR DESIGN AND TECHNOLOGY IN ELECTRONIC PACKAGING (SIITME), 2015, : 103 - 106
  • [39] Image recognition using Radon transform
    Li, JH
    Pan, Q
    Zhang, HC
    Cui, PL
    [J]. 2003 IEEE INTELLIGENT TRANSPORTATION SYSTEMS PROCEEDINGS, VOLS. 1 & 2, 2003, : 741 - 744
  • [40] ECG based Human Identification using Short Time Fourier Transform and Histograms of Fiducial QRS Features
    Biran, Abdullah
    Jeremic, Aleksandar
    [J]. PROCEEDINGS OF THE 13TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 4: BIOSIGNALS, 2020, : 324 - 329