The ArcCHECK diode array for dosimetric verification of HybridArc

被引:26
|
作者
Petoukhova, A. L. [1 ]
van Egmond, J. [1 ]
Eenink, M. G. C. [1 ]
Wiggenraad, R. G. J. [1 ]
van Santvoort, J. P. C. [1 ]
机构
[1] Radiotherapy Ctr W, NL-2501 CK The Hague, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 16期
关键词
MODULATED ARC THERAPY; QUALITY-ASSURANCE; DOSE CALCULATION; CLINICAL-EVALUATION; TREATMENT DELIVERY; IMRT; PHOTON; PHANTOM; TOMOTHERAPY; ALGORITHM;
D O I
10.1088/0031-9155/56/16/021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this work is to evaluate dosimetric accuracy of a new treatment modality, HybridArc, in iPlan RT Dose 4.5 (BrainLAB, Feldkirchen, Germany) using a four-dimensional diode array (ArcCHECK, Sun Nuclear Corporation, Melbourne, USA). HybridArc is able to enhance dynamic conformal arcs with inversely planned elements. HybridArc plans for various sites (intracranial and extracranial) were constructed and after that these plans were recalculated for the ArcCHECK diode array with Monte Carlo (MC) and Pencil Beam (PB) dose algorithms in iPlan RT Dose. All measurements of these HybridArc plans were performed with 6 MV photon beams of a Novalis accelerator (BrainLAB, Feldkirchen, Germany) using the ArcCHECK device without and with an insert containing an ionization chamber. Comparison of the absolute dose distributions measured and calculated in iPlan RT Dose with the MC algorithm at the cylinder of the ArcCHECK diode array for HybridArc plans gives good agreement, even for the 2% dose difference and 2 mm distance-to-agreement criteria. The PB calculations significantly differ from the ArcCHECK measurements so that the MC algorithm is found to be superior to the PB algorithm in the calculation of the HybridArc plans. One of the drawbacks of the PB calculations in iPlan RT Dose is the too large arc step size of 10 degrees. Use of a finer angular resolution may improve the PB results significantly.
引用
收藏
页码:5411 / 5428
页数:18
相关论文
共 50 条
  • [1] ArcCHECK Diode Array for Dosimetric Verification of HybridArc
    Petoukhova, A.
    Egmond, J.
    Eenink, M.
    Wiggenraad, R.
    Santvoort, J.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [2] Analyzing the performance of ArcCHECK diode array detector for VMAT plan
    Thiyagarajan, Rajesh
    Nambiraj, Arunai
    Sinha, Sujit Nath
    Yadav, Girigesh
    Kumar, Ashok
    Subramani, Vikraman
    Kothandaraman
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2016, 21 (01) : 50 - 56
  • [3] Analysis of ArcCHECK Diode Array Performance for ViewRay Quality Assurance
    Ellefson, S.
    Culberson, W.
    Bednarz, B.
    DeWerd, L.
    Bayouth, J.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3668 - 3668
  • [4] On Rotational Measurements with the ArcCHECK 3D Diode Array
    Feygelman, V.
    Zhang, G.
    Stevens, C.
    Nelms, B.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [5] ON ROTATIONAL MEASUREMENTS WITH THE ARCCHECK 4D DIODE ARRAY
    Skorska, M.
    Ryczkowski, A.
    Piotrowski, T.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S535 - S535
  • [6] DOSIMETRIC PERFORMANCE OF A 2D DIODE ARRAY FOR VERIFICATION OF VOLUMETRIC MODULATED ARC THERAPY
    Nakada, R.
    Tatsumi, D.
    Sakamoto, M.
    Inoue, M.
    Ichida, T.
    Ishii, K.
    Tsutsumi, S.
    Ogino, R.
    Hosono, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S212 - S212
  • [7] Commissioning and Comprehensive Evaluation of the ArcCHECK Cylindrical Diode Array for VMAT QA
    Chaswal, V.
    Weldon, M.
    Gupta, N.
    Rong, Y.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 373 - 373
  • [8] IMAT Patient Specific Quality Assurance Using ArcCHECK Diode Array Detector
    Thiyagarajan, Rajesh
    Sinha, S.
    Yadav, G.
    Ashokkumar, S.
    Raman, Kothanda
    Mishra, M.
    Nambiraj, N. Arunai
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3733 - 3733
  • [9] WEEKLY VERIFICATION OF DOSIMETRIC DATA FOR VIRTUAL WEDGE USING A 2D DIODE DETECTOR ARRAY
    Ogata, Toshiyuki
    Koizumi, Masahiko
    Sumida, Iori
    Takahashi, Yutaka
    Akino, Yuichi
    Isohashi, Fumiaki
    Konishi, Koji
    Yoshioka, Yasuo
    Inoue, Takehiro
    [J]. MEDICAL DOSIMETRY, 2011, 36 (03) : 246 - 249
  • [10] Dosimetric Verification by Using the ArcCHECK System and 3DVH Software for Various Target Sizes
    Song, Jin Ho
    Shin, Hun-Joo
    Kay, Chul Seung
    Son, Seok Hyun
    [J]. PLOS ONE, 2015, 10 (03):