Analytical model for managing hypotony after implantation surgery of a glaucoma drainage device

被引:2
|
作者
Agujetas, R. [1 ,2 ]
Kudiesh, B. [3 ,4 ]
Fernandez-Vigo, J., I [4 ,5 ]
Garcia-Feijoo, Julian [4 ,5 ]
Montanero, J. M. [1 ,2 ]
机构
[1] Univ Extremadura, Dept Ingn Mecan Energet & Mat, E-06006 Badajoz, Spain
[2] Univ Extremadura, Inst Comp Cient Avanzada ICCAEx, E-06006 Badajoz, Spain
[3] Puerta de Hierro Univ Hosp, Dept Ophthalmol, Madrid, Spain
[4] Int Ctr Adv Ophthalmol, Madrid, Spain
[5] Univ Complutense OFTARED, San Carlos Clin Hosp, Hlth Res Inst IdISSC, Dept Ophthalmol, Madrid, Spain
关键词
Aqueous humor flow; Intraocular pressure; Glaucom; Glaucoma drainage device; ANTERIOR-CHAMBER; INTRAOCULAR-LENS; FLUID-MECHANICS; AQUEOUS-HUMOR; HUMAN EYE; FLOW; TUBE;
D O I
10.1007/s10237-021-01494-w
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The main aim of glaucoma treatment is to reduce the intraocular pressure (IOP). One of the most common surgical treatments of glaucoma is the implantation of a glaucoma drainage device to drain the aqueous humor from the anterior chamber to a filtration bleb, where the aqueous humor is absorbed. In some cases, the excess of drainage causes ocular hypotony, which constitutes a sight-threatening complication. To prevent hypotony after this intervention, surgeons frequently introduce a suture into the device tube, which increases the hydraulic resistance of the tube and, therefore, the IOP. This study aims to provide an analytical model to correct hypotony following implantation surgery of a glaucoma drainage device, which may help glaucoma surgeons decide on hypotony treatment. The results indicate that the IOP after implanting a cylindrical tube around 300 mu m in diameter is essentially the same as that built up in the filtering bleb and can hardly be controlled by introducing a straight suture unless the suture diameter is slightly lower than that of the tube. On the contrary, when the tube diameter is smaller than, for example, 100 mu m, significant reductions of the IOP can be obtained by introducing a thin suture into the tube.
引用
收藏
页码:2061 / 2070
页数:10
相关论文
共 50 条
  • [1] Analytical model for managing hypotony after implantation surgery of a glaucoma drainage device
    R. Agujetas
    B. Kudiesh
    J. I. Fernández-Vigo
    Julián García-Feijóo
    J. M. Montanero
    [J]. Biomechanics and Modeling in Mechanobiology, 2021, 20 : 2061 - 2070
  • [2] Intraluminal Suture Placement for Management of Hypotony After Glaucoma Drainage Device Surgery
    Tang, Minjia
    Anchala, Anupama R.
    Tanna, Angelo P.
    [J]. JOURNAL OF GLAUCOMA, 2024, 33 (08) : 607 - 611
  • [3] Ab interno intraluminal suture to reverse ocular hypotony after glaucoma drainage device implantation
    Fontana, Luigi
    Moramarco, Antonio
    Iannetta, Danilo
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (01) : NP301 - NP302
  • [4] Diplopia after glaucoma drainage device implantation
    Abdelaziz, Amany
    Capo, Hilda
    Banitt, Michael R.
    Schiffman, Joyce
    Feuer, William J.
    McKeown, Craig A.
    Spencer, Nehemiah E.
    Parrish, Richard K.
    [J]. JOURNAL OF AAPOS, 2013, 17 (02): : 192 - 196
  • [5] Capsule excision and Ologen™ implantation for revision after glaucoma drainage device surgery
    André Rosentreter
    Anne C. Mellein
    Walter W. Konen
    Thomas S. Dietlein
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 1319 - 1324
  • [6] Capsule excision and Ologen™ implantation for revision after glaucoma drainage device surgery
    Rosentreter, Andre
    Mellein, Anne C.
    Konen, Walter W.
    Dietlein, Thomas S.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (09) : 1319 - 1324
  • [7] Aqueous misdirection after glaucoma drainage device implantation
    Greenfield, DS
    Tello, C
    Budenz, DL
    Liebmann, JM
    Ritch, R
    [J]. OPHTHALMOLOGY, 1999, 106 (05) : 1035 - 1040
  • [8] Comparison of refractive outcomes after combined cataract and glaucoma surgery: trabeculectomy and glaucoma drainage device implantation
    Asano, Shotaro
    Koh, Teck Chang Victor
    Aquino, Maria Cecilia
    Lim, Ka-Ann Dawn
    Sng, Chelvin Cheryl Anges
    Loon, Seng Chee
    Chew, Tec Kuan Paul
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (09): : 1133 - 1138
  • [9] Ab interno intraluminal stenting with Supramid suture for hypotony following glaucoma drainage device implantation
    Raghua, K.
    Kavithaa, S.
    Puthuranb, G. V.
    Odayappana, A.
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (08): : E272 - E273
  • [10] Hypotony after glaucoma filtration surgery
    Rahman, A
    Mendonca, M
    Simmons, RB
    Simmons, RJ
    [J]. INTERNATIONAL OPHTHALMOLOGY CLINICS, 2000, 40 (01) : 127 - 136