Analytical model for managing hypotony after implantation surgery of a glaucoma drainage device

被引:2
|
作者
Agujetas, R. [1 ,2 ]
Kudiesh, B. [3 ,4 ]
Fernandez-Vigo, J., I [4 ,5 ]
Garcia-Feijoo, Julian [4 ,5 ]
Montanero, J. M. [1 ,2 ]
机构
[1] Univ Extremadura, Dept Ingn Mecan Energet & Mat, E-06006 Badajoz, Spain
[2] Univ Extremadura, Inst Comp Cient Avanzada ICCAEx, E-06006 Badajoz, Spain
[3] Puerta de Hierro Univ Hosp, Dept Ophthalmol, Madrid, Spain
[4] Int Ctr Adv Ophthalmol, Madrid, Spain
[5] Univ Complutense OFTARED, San Carlos Clin Hosp, Hlth Res Inst IdISSC, Dept Ophthalmol, Madrid, Spain
关键词
Aqueous humor flow; Intraocular pressure; Glaucom; Glaucoma drainage device; ANTERIOR-CHAMBER; INTRAOCULAR-LENS; FLUID-MECHANICS; AQUEOUS-HUMOR; HUMAN EYE; FLOW; TUBE;
D O I
10.1007/s10237-021-01494-w
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The main aim of glaucoma treatment is to reduce the intraocular pressure (IOP). One of the most common surgical treatments of glaucoma is the implantation of a glaucoma drainage device to drain the aqueous humor from the anterior chamber to a filtration bleb, where the aqueous humor is absorbed. In some cases, the excess of drainage causes ocular hypotony, which constitutes a sight-threatening complication. To prevent hypotony after this intervention, surgeons frequently introduce a suture into the device tube, which increases the hydraulic resistance of the tube and, therefore, the IOP. This study aims to provide an analytical model to correct hypotony following implantation surgery of a glaucoma drainage device, which may help glaucoma surgeons decide on hypotony treatment. The results indicate that the IOP after implanting a cylindrical tube around 300 mu m in diameter is essentially the same as that built up in the filtering bleb and can hardly be controlled by introducing a straight suture unless the suture diameter is slightly lower than that of the tube. On the contrary, when the tube diameter is smaller than, for example, 100 mu m, significant reductions of the IOP can be obtained by introducing a thin suture into the tube.
引用
收藏
页码:2061 / 2070
页数:10
相关论文
共 50 条
  • [41] Managing glaucoma drainage device tube leak with cyanoacrylate
    Kusabara, Alessandra A.
    Kasahara, Niro
    [J]. ACTA OPHTHALMOLOGICA, 2017, 95 (07) : E662 - E662
  • [42] Comment on: Hypotonous malignant glaucoma following glaucoma drainage device implantation
    Singhal, Deepali
    Tripathy, Koushik
    Tewari, Ruchir
    Nath, Manas
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (01) : 341 - +
  • [43] Response to: Anterior Corneal Folds in Postoperative Hypotony Following Glaucoma Drainage Surgery
    Abualhasan, Hamza
    Mimouni, Michael
    Safuri, Shadi
    Blumenthal, Eytan Z.
    [J]. JOURNAL OF GLAUCOMA, 2020, 29 (07) : E78 - E79
  • [44] Novel Surgical Techniques to Control Flow With PreserFlo MicroShunt for Late Hypotony After Baerveldt Drainage Device Implantation
    Fritsche, Raphael
    Mueller, Luzia
    Bochmann, Frank
    [J]. JOURNAL OF GLAUCOMA, 2022, 31 (10) : E101 - E104
  • [45] Novel Surgical Techniques to Control Flow With PreserFlo MicroShunt for Late Hypotony After Baerveldt Drainage Device Implantation
    Malick, Huzaifa
    Stead, Richard E.
    [J]. JOURNAL OF GLAUCOMA, 2023, 32 (09) : E112 - E112
  • [46] Truncation of In Situ Baerveldt Glaucoma Drainage Device for Treatment of Late Persistent Postoperative Hypotony
    Chen, Philip P.
    [J]. JOURNAL OF GLAUCOMA, 2017, 26 (02) : E113 - E114
  • [47] Complications of Glaucoma Drainage Device Surgery: A Review
    Giovingo, Michael
    [J]. SEMINARS IN OPHTHALMOLOGY, 2014, 29 (5-6) : 397 - 402
  • [48] Glaucoma Drainage Device Surgery Outcomes in Children With Uveitic Glaucoma
    Gkaragkani, Evangelia
    Jayaram, Hari
    Papadopoulos, Maria
    Pavesio, Carlos
    Brookes, John
    Khaw, Peng T.
    El Sayed, Yasmine M.
    Clarke, Jonathan
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 251 : 5 - 11
  • [49] Glaucoma drainage device surgery outcomes for pediatric uveitic glaucoma
    Clarke, Jonathan C.
    Gkaragkani, Evangelia
    Papadopoulos, Maria
    Pavesio, Carlos
    Brookes, John
    Khaw, Peng Tee
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [50] Endophthalmitis With Corneal Infiltrate After EX-PRESS Glaucoma Drainage Device Implantation
    Cherof, Amy M.
    SooHoo, Jeffery R.
    Kahook, Malik Y.
    Seibold, Leonard K.
    [J]. JOURNAL OF GLAUCOMA, 2016, 25 (03) : E277 - E279