Diplopia after glaucoma drainage device implantation

被引:28
|
作者
Abdelaziz, Amany [1 ]
Capo, Hilda [1 ]
Banitt, Michael R. [1 ]
Schiffman, Joyce [1 ]
Feuer, William J. [1 ]
McKeown, Craig A. [1 ]
Spencer, Nehemiah E. [1 ]
Parrish, Richard K. [1 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL 33136 USA
来源
JOURNAL OF AAPOS | 2013年 / 17卷 / 02期
基金
美国国家卫生研究院;
关键词
ACQUIRED BROWNS-SYNDROME; VALVE IMPLANT; CLINICAL-EXPERIENCE; MOTILITY DISTURBANCES; BAERVELDT IMPLANT; AHMED GLAUCOMA; 350-MM(2); HYPERTROPIA; SECONDARY; OUTCOMES;
D O I
10.1016/j.jaapos.2012.11.017
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE To determine incidence of diplopia after glaucoma drainage device (GDD) surgery and to report treatment outcomes. METHODS Financial claims data were used to identify patients who underwent GDD surgery (CPT [Current Procedural Terminology] 66180) at the Bascom Palmer Eye Institute from January 2, 1991, through December 31, 2005. After a second claims data search, the medical records of patients diagnosed with diplopia (International Classification of Diseases, 9th Revision code 368.2) and those who underwent extraocular muscle surgery (CPT-4 code 67311-67335) after GDD implantation were reviewed retrospectively. RESULTS A total of 2,661 patients underwent GDD surgery during the study period. Charges were submitted for 59 patients for strabismus surgery or office visits relating to diplopia. Of these, 27 patients were excluded because medical records did not document diplopia or included pre-existing diplopia, cranial nerve palsy, or diplopia attributed to another ocular procedure. The remaining 32 patients developed diplopia secondary to GDD. Superotemporal quadrant GDDs were identified in 23 eyes and inferonasal quadrant placement in 9 eyes. The 1-year cumulative incidence of diplopia was 1.4%. No patient developed diplopia after 1 year. The mean follow-up after diagnosis for patients with diplopia was 48 +/- 27 months (range, 1-124 months). The mean time of onset of diplopia after GDD implantation was 66 +/- 62 days, with median onset of 42 days (range, 8-278 days). Treatment of diplopia included prisms in 17 cases (53.1%), no treatment in 13 (40.6%), other therapies in 2 (6.3%), and surgery after prismatic treatment failed in 3 (9.4%). CONCLUSIONS The incidence of diplopia after GDD surgery is low, and most patients are treated with prisms.
引用
收藏
页码:192 / 196
页数:5
相关论文
共 50 条
  • [1] Motility changes and diplopia after Baerveldt glaucoma drainage device implantation or trabeculectomy
    Islamaj, E.
    Jordaan-Kuip, C. P.
    Vermeer, K. A.
    Lemij, H. G.
    de Waard, P. W. T.
    [J]. ACTA OPHTHALMOLOGICA, 2018, 96 : 24 - 24
  • [2] Motility Changes and Diplopia After Baerveldt Glaucoma Drainage Device Implantation or After Trabeculectomy
    Islamaj, Esma
    Jordaan-Kuip, Caroline P.
    Vermeer, Koen A.
    Lemij, Hans G.
    de Waard, Peter W. T.
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (05):
  • [3] Aqueous misdirection after glaucoma drainage device implantation
    Greenfield, DS
    Tello, C
    Budenz, DL
    Liebmann, JM
    Ritch, R
    [J]. OPHTHALMOLOGY, 1999, 106 (05) : 1035 - 1040
  • [4] Implantation of a second glaucoma drainage device
    Brian A. Francis
    Rodrigo A. B. Fernandes
    Handan Akil
    Vikas Chopra
    Bruno Diniz
    James Tan
    Alex Huang
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2017, 255 : 1019 - 1025
  • [5] Implantation of a second glaucoma drainage device
    Francis, Brian A.
    Fernandes, Rodrigo A. B.
    Akil, Handan
    Chopra, Vikas
    Diniz, Bruno
    Tan, James
    Huang, Alex
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (05) : 1019 - 1025
  • [6] Baerveldt glaucoma drainage device induces diplopia and motility changes
    Islamaj, Esma
    Jordaan-Kuip, Caroline P.
    Vermeer, Koen A.
    Lemij, Hans G.
    De Waard, Peter W. T.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [7] Factors related to hypertensive phase after glaucoma drainage device implantation
    Pitukcheewanont, Orathai
    Tantisevi, Visanee
    Chansangpetch, Sunee
    Rojanapongpun, Prin
    [J]. CLINICAL OPHTHALMOLOGY, 2018, 12 : 1479 - 1486
  • [8] Risk factors for the hypertensive phase after implantation of a glaucoma drainage device
    Jung, Kyoung In
    Park, Chan Kee
    [J]. ACTA OPHTHALMOLOGICA, 2016, 94 (05) : e260 - e267
  • [9] Magnetically actuated glaucoma drainage device for regulating intraocular pressure after implantation
    Pereira, Ines C. F.
    Wyss, Hans M.
    Beckers, Henny J.
    den Toonder, Jaap M. J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [10] Analytical model for managing hypotony after implantation surgery of a glaucoma drainage device
    R. Agujetas
    B. Kudiesh
    J. I. Fernández-Vigo
    Julián García-Feijóo
    J. M. Montanero
    [J]. Biomechanics and Modeling in Mechanobiology, 2021, 20 : 2061 - 2070