Validation of the MyWellness Key in walking and running speeds

被引:0
|
作者
Bergamin, Marco [1 ]
Ermolao, Andrea [1 ]
Sieverdes, John C. [2 ]
Zaccaria, Marco
Zanuso, Silvano [3 ]
机构
[1] Univ Padua, Sports Med Div, Dept Med & Surg Sci, Fac Med, Padua, Italy
[2] Univ S Carolina, Dept Exercise Sci, Arnold Sch Publ Hlth, Columbia, SC 29208 USA
[3] Univ Greenwich, Dept Sports Sci, Ctr Sport Sci & Human Performance, London SE18 6PF, England
关键词
Accelerometry; Indirect Calorimetry; Measurement; Physical Activity; PHYSICAL-ACTIVITY; ENERGY-EXPENDITURE; COMPUTER-SCIENCE; CALTRAC ACCELEROMETER; ACTIVITY MONITORS; VALIDITY; RELIABILITY; CALIBRATION; PREDICT; COST;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study was performed to assess the validity of the MyWellness Key (MWK) accelerometer during a treadmill-based protocol. The identification of different exercise intensities is imperative to objectively measure time spent at a specified exercise intensity. Thirty subjects, 15 men and 15 women (age = 24.5 +/- 2.6 years; body mass index = 22.5 +/- 2.5 kg.m(-1)), participated in a 4-phase treadmill protocol (5 minutes each one) using three different walking velocities (3, 4.5, and 6 km.h(-1)) and run (8 km.h(-1)) while outfitted with a MWK uniaxial accelerometer. Oxygen consumption was measured by indirect calorimetry (ICVO2). Results: The relationship between VO2 predicted from MWK (MWKVO2) and oxygen consumption (VO2 (ICVO2)), yielded a high and significant correlation (r = 0.944; p < 0.001) with standard error of estimate (SEE) = 2.42 mL.kg(-1).min(-1). The average differences between the two methods (MWKVO2 - ICVO2) were -0.79 (-8.8% at 3 km.h(-1)), -0.02 (-0.2% at 4.5 km.h(-1)), 0.51 (3.3% at 6 km.h(-1)) and -0.74 (-2.7% at 8 km.h(-1)) ml.kg(-1).min(-1). Only the 3 km.h(-1) speed showed a difference when compared to the criterion measure (p < 0.001). Bland and Altman analysis revealed less than a 1 MET difference in the mean at each point estimate and relatively tight distribution with the standard errors, especially with the 2 moderate walking speeds. Conclusions: We found a high correlation between oxygen utilization and the MWK with low standard errors estimates. This indicates that this accelerometer can be used to identify exercise intensities that are related to walking and running.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [31] Walking and running at resonance
    Ahlborn, BK
    Blake, RW
    ZOOLOGY, 2002, 105 (02) : 165 - 174
  • [32] Walking before running
    不详
    NATURE IMMUNOLOGY, 2002, 3 (05) : 409 - 409
  • [33] WALKING, RUNNING AND JUMPING
    HILDEBRAND, M
    AMERICAN ZOOLOGIST, 1961, 1 (04): : 452 - 453
  • [34] WALKING, RUNNING, AND JUMPING
    HILDEBRAND, M
    AMERICAN ZOOLOGIST, 1962, 2 (02): : 151 - 155
  • [35] Optimizing walking and running
    Tytell, E
    JOURNAL OF EXPERIMENTAL BIOLOGY, 2006, 209 (07): : V - V
  • [36] Walking Running Crawling
    Transtromer, Tomas
    KENYON REVIEW, 2013, 35 (02): : 3 - 3
  • [37] KINEMATICS OF RUNNING AT DIFFERENT SLOPES AND SPEEDS
    Padulo, Johnny
    Annino, Giuseppe
    Migliaccio, Gian M.
    D'Ottavio, Stefano
    Tihanyi, Jozsef
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2012, 26 (05) : 1331 - 1339
  • [38] Changshu mill running at record speeds
    Oinonen, Hannu
    PAPERI JA PUU-PAPER AND TIMBER, 2007, 89 (04): : 176 - +
  • [39] A quantification of the treadmill 6-min walk test using the MyWellness Key™ accelerometer
    Sparks, S. Andy
    Hilton, Nathan P.
    JOURNAL OF SPORT AND HEALTH SCIENCE, 2015, 4 (02) : 188 - 194
  • [40] Analysis of steady and target walking speeds in limit cycle walking
    Xiao X.
    Asano F.
    Xiao, Xuan (s1220206@jaist.ac.jp), 1600, Springer Science and Business Media Deutschland GmbH (05): : 454 - 465