Investigation of a noninvasive detector system for quantitative [O-15]water blood flow studies in PET

被引:7
|
作者
Aykac, M [1 ]
Hichwa, RD
Watkins, GL
机构
[1] Univ Iowa, PET Imaging Ctr, Dept Radiol, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Phys & Astron, Iowa City, IA 52242 USA
关键词
D O I
10.1109/23.910829
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The investigation of human cerebral function has been one of the most challenging subjects in the last century. Imaging studies that use positron emission tomography (PET) with [0-15]water have been central for the assessment of neurophysiological activity. Accurate and quantitative estimation of regional cerebral blood flow (rCBF) for mapping of brain function requires measurement of the post-injection arterial time course of [0-15]water. The overall purpose of this work is to design and build a small inexpensive tomograph that can be placed around a subject's neck or wrist to noninvasively measure the arterial radioactivity input function. Monte Carlo simulations and experimental investigations have been performed to assist in defining the design characteristics of the detectors to be used for this system.
引用
收藏
页码:31 / 37
页数:7
相关论文
共 50 条
  • [41] ENHANCED DETECTABILITY OF CBF CHANGES IN PET [O-15] WATER ACTIVATION STUDIES OF HUMAN COGNITION
    KOEPPE, RA
    MINOSHIMA, S
    BUCHTEL, HA
    BOTTI, LE
    HENRY, TR
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P138 - P138
  • [42] Parametric images of blood flow in oncology PET studies using [15O]water
    Lodge, MA
    Carson, RE
    Carrasquillo, JA
    Whatley, M
    Libutti, SK
    Bacharach, SL
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (11) : 1784 - 1792
  • [43] THE EFFECT OF INSULIN ON BLOOD-VOLUME AND FLOW IN SKELETAL-MUSCLE OF ESSENTIAL HYPERTENSIVES - STUDIES USING (CO)-O-15, (H2O)-O-15 AND POSITRON EMISSION TOMOGRAPHY (PET)
    NUUTILA, P
    LAINE, H
    RAITAKARI, M
    RUOTSALAINEN, U
    TERAS, M
    SIPILA, H
    KNUUTI, J
    YKIJARVINEN, H
    DIABETES, 1995, 44 : A196 - A196
  • [44] FUNCTIONAL-STUDIES WITH (H2O)-O-15 PET
    MOMOSE, T
    SASAKI, Y
    SAKURAI, Y
    IWATA, M
    BIOMEDICAL RESEARCH-TOKYO, 1992, 13 : 77 - 82
  • [45] Noninvasive quantitation of cerebral blood flow using oxygen-15-water and a Dual-PET system
    Iida, H
    Miura, S
    Shoji, Y
    Ogawa, T
    Kado, H
    Narita, Y
    Hatazawa, J
    Eberl, S
    Kanno, I
    Uemura, K
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (10) : 1789 - 1798
  • [46] QUANTITATIVE MEASUREMENT OF MYOCARDIAL BLOOD-FLOW WITH O-15 WATER AND POSITRON COMPUTED-TOMOGRAPHY - AN ASSESSMENT OF POTENTIAL AND PROBLEMS
    HUANG, SC
    SCHWAIGER, M
    CARSON, RE
    CARSON, J
    HANSEN, H
    SELIN, C
    HOFFMAN, EJ
    MACDONALD, N
    SCHELBERT, HR
    PHELPS, ME
    JOURNAL OF NUCLEAR MEDICINE, 1985, 26 (06) : 616 - 625
  • [47] QUANTITATIVE MEASUREMENT OF RENAL PLASMA-FLOW BY POSITRON EMISSION TOMOGRAPHY WITH O-15 WATER
    INABA, T
    YAMASHITA, M
    KAWASE, Y
    NAKAHASHI, H
    WATANABE, H
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1989, 159 (04): : 283 - 289
  • [48] AUTOMATED PRODUCTION OF O-15 LABELED BUTANOL FOR PET MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW
    MOERLEIN, SM
    GAEHLE, GG
    LECHNER, KR
    BERA, RK
    WELCH, MJ
    APPLIED RADIATION AND ISOTOPES, 1993, 44 (09) : 1213 - 1218
  • [49] AN ONLINE SYNTHESIS OF [O-15]N2O - NEW BLOOD-FLOW TRACER FOR PET IMAGING
    DIKSIC, M
    YAMAMOTO, YL
    FEINDEL, W
    JOURNAL OF NUCLEAR MEDICINE, 1983, 24 (07) : 603 - 607
  • [50] EVALUATION OF MYOCARDIAL PERFUSION USING PET WITH (O-15) WATER AND BUTANOL
    BERRIDGE, MS
    NELSON, AD
    ELLERT, E
    CASSIDY, EH
    MIRALDI, F
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P77 - P77