Investigation of a noninvasive detector system for quantitative [O-15]water blood flow studies in PET

被引:7
|
作者
Aykac, M [1 ]
Hichwa, RD
Watkins, GL
机构
[1] Univ Iowa, PET Imaging Ctr, Dept Radiol, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Phys & Astron, Iowa City, IA 52242 USA
关键词
D O I
10.1109/23.910829
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The investigation of human cerebral function has been one of the most challenging subjects in the last century. Imaging studies that use positron emission tomography (PET) with [0-15]water have been central for the assessment of neurophysiological activity. Accurate and quantitative estimation of regional cerebral blood flow (rCBF) for mapping of brain function requires measurement of the post-injection arterial time course of [0-15]water. The overall purpose of this work is to design and build a small inexpensive tomograph that can be placed around a subject's neck or wrist to noninvasively measure the arterial radioactivity input function. Monte Carlo simulations and experimental investigations have been performed to assist in defining the design characteristics of the detectors to be used for this system.
引用
收藏
页码:31 / 37
页数:7
相关论文
共 50 条
  • [31] PET O-15 SYMPTOM PROVOCATION STUDIES OF ANXIETY DISORDERS
    RAUCH, SL
    SAVAGE, CR
    ALPERT, NM
    BREITER, HCR
    BAER, L
    MIGUEL, E
    FISCHMAN, AJ
    MANZO, P
    MORETTI, C
    JENIKE, MA
    BIOLOGICAL PSYCHIATRY, 1994, 35 (09) : 658 - 658
  • [32] A CONTINUOUS-FLOW INPUT FUNCTION DETECTOR FOR H-2 O-15 BLOOD-FLOW STUDIES IN POSITRON EMISSION TOMOGRAPHY
    HUTCHINS, GD
    HICHWA, RD
    KOEPPE, RA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 546 - 549
  • [33] SYNCHRONIZED PRODUCTION AND INSTILLATION OF (H2O)-O-15 FOR THE QUANTITATIVE MEASUREMENT OF BLOOD-FLOW AND REGIONAL EXTRAVASCULAR WATER
    SAJI, H
    ENOKI, K
    NISHIHARA, Y
    YOKOYAMA, A
    TORIZUKA, K
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 1984, 21 (11-1): : 1262 - 1263
  • [34] Adenosine-induced myocardial flow reactivity in pig as assessed with O-15 water PET
    Jino, H
    Kawachi, N
    Teramoto, N
    Ohta, Y
    Kudomi, N
    Hayashi, T
    Watabe, H
    Yokoyama, IU
    Iida, H
    PET AND MOLECULAR IMAGING: STATE OF THE ART AND FUTURE PERSPECTIVES, 2004, 1264 : 117 - 125
  • [35] POSITRON IMAGING OF INTRAVENOUS O-15 LABELED WATER FOR CEREBRAL BLOOD-FLOW
    JONES, SC
    GREENBERG, JH
    DANN, R
    ROBINSON, GD
    KUSHNER, M
    ALAVI, A
    REIVICH, M
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (05) : P49 - P49
  • [36] PHOTON-ACTIVATION - O-15 DECAY STUDIES OF TUMOR BLOOD-FLOW
    NUSSBAUM, GH
    HUGHES, WL
    EMAMI, B
    HAKEN, RT
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 782 - 782
  • [37] PHOTON-ACTIVATION - O-15 DECAY STUDIES OF TUMOR BLOOD-FLOW
    TENHAKEN, RK
    NUSSBAUM, GH
    EMAMI, B
    HUGHES, WL
    MEDICAL PHYSICS, 1981, 8 (03) : 324 - 336
  • [38] Methods for the correction of vascular artifacts in PET O-15 water brain-mapping studies
    Chen, Kewei
    Reiman, Eric M.
    Lawson, Michael
    Yun, Lang-sheng
    Bandy, Daniel
    Palant, Anita
    IEEE Transactions on Nuclear Science, 1996, 43 (6 Pt 2) : 3308 - 3314
  • [39] COMPARISON OF N-13 AMMONIA AND O-15 WATER FOR QUANTIFICATION OF RENAL CORTICAL BLOOD-FLOW (RCBF) WITH PET
    NITZSCHE, EU
    CHOI, Y
    HOH, CK
    HAWKINS, RA
    HUANG, SC
    SCHELBERT, HR
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P50 - P50
  • [40] SYSTEM FOR O-15 LABELED BLOOD FOR MEDICAL APPLICATIONS
    SUBRAMANYAM, R
    BUCELEWICZ, WM
    HOOP, B
    JONES, SC
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1977, 28 (1-2): : 21 - 24