Design Study of the Absorber Detector of a Compton Camera for On-line Control in Ion Beam Therapy

被引:0
|
作者
Richard, M. -H. [1 ,2 ,3 ,4 ]
Dahoumane, M. [1 ,2 ,3 ]
Dauvergne, D. [1 ,2 ,3 ]
Dedes, G. [1 ,2 ,3 ]
De Rydt, M. [1 ,2 ,3 ]
Freud, N. [1 ,4 ]
Letang, J. M. [1 ,4 ]
Lojacono, X. [1 ,4 ]
Krimmer, J. [1 ,2 ,3 ]
Maxim, V. [1 ,4 ]
Montarou, G. [5 ,6 ]
Ray, C. [1 ,2 ,3 ]
Roellinghoff, F. [1 ,4 ]
Testa, E. [1 ,2 ,3 ]
Walenta, A. H. [1 ,2 ,3 ]
机构
[1] Univ Lyon, F-69622 Villeurbanne, France
[2] Univ Lyon 1, F-69622 Villeurbanne, France
[3] CNRS IN2P3, IPNL, UMR 5822, F-69622 Villeurbanne, France
[4] Univ Lyon 1, CNRS, INSERM,UlO44, INSA Lyon,Ctr Leon Berard,CREATIS,UMR 5220, F-69622 Villeurbanne, France
[5] Univ Clermont Ferrand 2, F-63177 Clermont Ferrand, France
[6] CNRS IIN2P3, LPC Clermont, UMR 6533, F-63177 Aubiere, France
关键词
Compton camera; hadrontherapy; ion beam therapy; prompt gamma; Geant4; LaBr3; NaI; LYSO;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to take advantage of the assets of ion irradiation, the position of the Bragg peak has to be monitored accurately. Here we propose a technique relying on the detection of the prompt gamma with a Compton camera. We reconstruct analytically the prompt-gamma emission points by intersecting the ion trajectories given by a beam hodoscope and the Compton cones reconstructed with the camera. For the Compton camera, we investigate the use of a stack of 2 mm thick silicon strip detectors as a scatterer and one scintillator as an absorber. The response of the Compton camera to a photon point source with a realistic spectrum (corresponding to the prompt-gamma spectrum emitted during the carbon irradiation of a water phantom) is studied. The goal of this study is to tune the design of the absorber detector. First the absorber detector dimensions are optimized. Then we compare the performances of three scintillators : LYSO, NaI and LaBr3. Finally, we study the influence of the spatial and energy resolutions of the absorber detector.
引用
收藏
页码:3496 / 3500
页数:5
相关论文
共 50 条
  • [31] Ion beam analysis and applications in on-line monitoring of ion induced modifications of materials
    Avasthi, DK
    [J]. MATERIALS SCIENCE APPLICATIONS OF ION BEAM TECHNIQUES, 1997, 248-2 : 405 - 408
  • [32] Optoacoustical tissue differentiation for on-line therapy control
    Oberheide, U
    Jansen, B
    Bruder, I
    Lubatschowski, H
    Welling, H
    Ertmer, W
    [J]. OPTICAL BIOPSY AND TISSUE OPTICS, 2000, 4161 : 37 - 45
  • [33] PET application as a Compton camera for proton beam range verification: A preliminary study
    Kozani, Majid Kazemi
    Rucinski, Antoni
    Moskal, Pawel
    [J]. BIO-ALGORITHMS AND MED-SYSTEMS, 2023, 19 (01) : 23 - 30
  • [34] IMAGING OF POINT SOURCES WITH A COMPTON CAMERA FOR IN-VIVO DOSE MONITORING OF ION BEAM IRRADIATION
    Kormoll, T.
    Fiedler, F.
    Golnik, C.
    Heidel, K.
    Kempe, M.
    Schoene, S.
    Sobiella, M.
    Zuber, K.
    Enghardt, W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S41 - S42
  • [35] In-beam PET imaging for on-line adaptive proton therapy: an initial phantom study
    Shao, Yiping
    Sun, Xishan
    Lou, Kai
    Zhu, Xiaorong R.
    Mirkovic, Dragon
    Poenisch, Falk
    Grosshans, David
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (13): : 3373 - 3388
  • [36] On-line direct control design for nonlinear systems
    Tanaskovic, Marko
    Fagiano, Lorenzo
    Novara, Carlo
    Morari, Manfred
    [J]. IFAC PAPERSONLINE, 2015, 48 (28): : 144 - 149
  • [37] An economic design of process adjustment for on-line control
    Wang, MC
    Yue, JF
    Chen, BT
    [J]. DECISION SCIENCES INSTITUTE 1998 PROCEEDINGS, VOLS 1-3, 1998, : 1714 - 1716
  • [38] Economic design of process adjustment for on-line control
    Wang, MC
    Yue, JF
    [J]. INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 2001, 39 (05) : 809 - 823
  • [39] Low Statistics Reconstruction of the Compton Camera Point Spread Function in 3D Prompt-γ Imaging of Ion Beam Therapy
    Lojacono, Xavier
    Richard, Marie-Helene
    Ley, Jean-Luc
    Testa, Etienne
    Ray, Cedric
    Freud, Nicolas
    Letang, Jean Michel
    Dauvergne, Denis
    Maxim, Voichita
    Prost, Remy
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3355 - 3363
  • [40] RECONSTRUCTING COMPTON CAMERA IMAGES FOR ION THERAPY MONITORING - CHALLENGES AND APPROACHES FACING THEM
    Schoene, S.
    Kormoll, T.
    Rohling, H.
    Enghardt, W.
    Fiedler, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S145 - S145