In-beam PET imaging for on-line adaptive proton therapy: an initial phantom study

被引:41
|
作者
Shao, Yiping [1 ]
Sun, Xishan [1 ]
Lou, Kai [1 ,2 ]
Zhu, Xiaorong R. [3 ]
Mirkovic, Dragon [3 ]
Poenisch, Falk [3 ]
Grosshans, David [4 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[2] Rice Univ, Dept Elect & Comp Engn, Houston, TX 77251 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 13期
关键词
proton radiotherapy; proton beam range; positron emission tomography; in-beam PET imaging; positron activity range; POSITRON-EMISSION-TOMOGRAPHY; CARBON-ION THERAPY; RANGE VERIFICATION; RECONSTRUCTION; DISTRIBUTIONS; FEASIBILITY; SIMULATION; READOUT; SCANNER; SYSTEM;
D O I
10.1088/0031-9155/59/13/3373
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We developed and investigated a positron emission tomography (PET) system for use with on-line (both in-beam and intra-fraction) image-guided adaptive proton therapy applications. The PET has dual rotating depth-of-interaction measurable detector panels by using solid-state photomultiplier (SSPM) arrays and LYSO scintillators. It has a 44 mm diameter trans-axial and 30 mm axial field-of-view (FOV). A 38 mm diameter polymethyl methacrylate phantom was placed inside the FOV. Both PET and phantom axes were aligned with a collimated 179.2 MeV beam. Each beam delivered similar to 50 spills (0.5 s spill and 1.5 s inter-spill time, 3.8 Gy at Bragg peak). Data from each beam were acquired with detectors at a given angle. Nine datasets for nine beams with detectors at nine different angles over 180 degrees were acquired for full-tomographic imaging. Each dataset included data both during and 5 min after irradiations. The positron activity-range was measured from the PET image reconstructed from all nine datasets and compared to the results from simulated images. A Na-22 disc-source was also imaged after each beam to monitor the PET system's performance. PET performed well except for slight shifts of energy photo-peak positions (<1%) after each beam, due mainly to the neutron exposure of SSPM that increased the dark-count noise. This minor effect was corrected offline with a shifting 350-650 keV energy window for each dataset. The results show a fast converging of activity-ranges measured by the prototype PET with high sensitivity and uniform resolution. Sub-mm activity-ranges were achieved with minimal 6 s acquisition time and three spill irradiations. These results indicate the feasibility of PET for intra-fraction beam-range verification. Further studies are needed to develop and apply a novel clinical PET system for on-line image-guided adaptive proton therapy.
引用
收藏
页码:3373 / 3388
页数:16
相关论文
共 50 条
  • [1] Monitoring Proton Therapy Through in-Beam PET: An Experimental Phantom Study
    Topi, A.
    Muraro, S.
    Battistoni, G.
    Belcari, N.
    Bisogni, M. G.
    Camarlinghi, N.
    Del Guerra, A.
    Ferrari, A.
    Kopec, R.
    Kraan, A. C.
    Krzempek, D.
    Krzempek, K.
    Morrocchi, M.
    Olko, P.
    Sala, P.
    Sportelli, G.
    Rosso, V.
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2020, 4 (02) : 194 - 201
  • [2] Monte Carlo Simulation Study of In-beam Intra-treatment PET Imaging for Adaptive Proton Therapy
    Lou, Kai
    Mirkovic, Dragan
    Sun, Xishan
    Zhu, Xiaorong Ronald
    Clark, John, Jr.
    Shao, Yiping
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [3] Exploring the Proton Intra-Beam Range Verification for On-Line Adaptive Therapy: Initial Study with Low-Dose Short-Acquisition PET Imaging
    Yang, D.
    Zhu, X.
    Ma, L.
    Chen, M.
    Park, Y.
    Lu, W.
    Shao, Y.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E166 - E167
  • [4] A PET Prototype for "In-Beam" Monitoring of Proton Therapy
    Vecchio, Sara
    Attanasi, Francesca
    Belcari, Nicola
    Camarda, Manuela
    Cirrone, G. A. Pablo
    Cuttone, Giacomo
    Di Rosa, Francesco
    Lanconelli, Nico
    Moehrs, Sascha
    Rosso, Valeria
    Russo, Giorgio
    Del Guerra, Alberto
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (01) : 51 - 56
  • [5] A PET prototype for in-beam monitoring of proton therapy
    Vecchio, Sara
    Attanasi, Francesca
    Belcari, Nicola
    Camarda, Manuela
    Cirrone, G. A. Pablo
    Cuttone, Giacomo
    Del Guerra, Alberto
    Di Rosa, Francesco
    Lanconelli, Nico
    Moehrs, Sascha
    Rosso, Valeria
    Russo, Giorgio
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1607 - +
  • [6] Experimental study on the feasibility of in-beam PET for accurate monitoring of proton therapy
    Parodi, K
    Pönisch, F
    Enghardt, W
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 778 - 786
  • [7] Preliminary results of an in-beam PET prototype for proton therapy
    Attanasi, F.
    Belcari, N.
    Camarda, M.
    Cirrone, G. A. P.
    Cuttone, G.
    Del Guerra, A.
    Di Rosa, F.
    Lanconelli, N.
    Rosso, V.
    Russo, G.
    Veechio, S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 296 - 299
  • [8] First results of the INSIDE in-beam PET scanner for the on-line monitoring of particle therapy treatments
    Piliero, M. A.
    Belcari, N.
    Bisogni, M. G.
    Camarlinghi, N.
    Cerello, P.
    Coli, S.
    Del Guerra, A.
    Ferrero, V.
    Fiorina, E.
    Giraudo, G.
    Kostara, E.
    Morrocchi, M.
    Pennazio, F.
    Peroni, C.
    Pirrone, G.
    Rivetti, A.
    Rolo, M. D.
    Rosso, V.
    Sportelli, G.
    Wheadon, R.
    [J]. JOURNAL OF INSTRUMENTATION, 2016, 11
  • [9] Analysis of in-beam PET time-profiles in proton therapy
    Kraan, A. C.
    Muraro, S.
    Battistoni, G.
    Belcari, N.
    Bisogni, M. G.
    Camarlinghi, N.
    Del Guerra, A.
    Ferrari, A.
    Kopec, R.
    Krzempek, D.
    Morrocchi, M.
    Olko, P.
    Sala, P.
    Skowronska, K.
    Sportelli, G.
    Topi, A.
    Rosso, V.
    [J]. JOURNAL OF INSTRUMENTATION, 2019, 14
  • [10] In-Beam PET Imaging in Carbon Therapy for Dose Verification
    Li, Zhongxing
    Fan, Yaming
    Dong, Ming
    Tong, Linge
    Zhao, Liang
    Yin, Yongzhi
    Chen, Ximeng
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (01) : 61 - 67