An interlaboratory comparison of sample presentation methods for the analysis of aqueous solutions using Fourier transform infrared spectroscopy

被引:0
|
作者
Bartl, F
Delgadillo, I
Davies, AN
Huvenne, JP
Meurens, M
Volka, K
Wilson, RH
机构
[1] INST FOOD RES, INST PHYS CHEM, NORWICH NR4 7UA, NORFOLK, ENGLAND
[2] UNIV MUNICH, DEPT QUIM, D-80333 MUNICH, GERMANY
[3] UNIV AVEIRO, P-3800 AVEIRO, PORTUGAL
[4] INST SPEKTROCHEM, CNRS, D-44013 DORTMUND, GERMANY
[5] SPECTROCHIM INFRAROUGE & RAMAN LAB, F-59655 VILLENEUVE DASCQ, FRANCE
[6] UNIV CATHOLIQUE LOUVAIN, DEPT ANALYT CHEM, B-1348 LOUVAIN, BELGIUM
[7] INST CHEM TECHNOL, CR-16628 PRAGUE 6, CZECH REPUBLIC
来源
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fourier transform infrared (FTIR) spectroscopy is becoming much more widely used as an analytical technique. It appears to be particularly useful for quantitative analysis, especially of aqueous solutions. However, there is a considerable variation in the cost and quality of instrumentation as well as a large number of accessories for sample presentation employing attenuated total reflectance (ATR). The objectives of the work reported in this paper were to investigate the effect of the choice of instrumentation on the quality of quantitative analyses as well as the effect of variable acquisition parameters. A series of experiments was designed in which samples were distributed to a number of workers using a range of FTIR instruments from different manufacturers and of differing quality. The workers were allowed to use the accessory of their own choice and to carry out a quantitative analysis of glucose solutions using their normal operating parameters. In following experiments the effects of instrumental and purge were considered and quantitative analysis was performed using a set of prescribed acquisition conditions. The results showed that there were significant differences in the quality of the spectra produced on the different combinations. However, although each worker produced quite different linear calibrations (in terms of slope and intercept), they all predicted the concentration of an unknown with a similar accuracy. However,later experiments showed that the low-cost bench-top instruments were not always so successful when the peaks used in the analysis were affected by residual water vapour interferences. Instrumental drift was noticeably worse for the low-cost instruments but this was an effect that could easily be eliminated by suitable baseline correction.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [31] COMPARISON OF ACYL-CARRIER PROTEIN AND OTHER PROTEIN STRUCTURES IN AQUEOUS-SOLUTIONS BY FOURIER-TRANSFORM INFRARED-SPECTROSCOPY
    ERNSTFONBERG, ML
    WORSHAM, LMS
    WILLIAMS, SG
    BIOCHIMICA ET BIOPHYSICA ACTA, 1993, 1164 (03) : 273 - 282
  • [32] The Quantified Analysis of Fresh Mutton Tenderness Using PLS Methods and Fourier Transform Near-Infrared Spectroscopy
    Zhang De-quan
    Chen Xiao-na
    Sun Su-qin
    Li Chun-hong
    Zhang Bo-lin
    Li Yong
    Li Shu-rong
    Li Qing-peng
    Zhou Hong-jie
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (11) : 2550 - 2553
  • [33] Spectroscopic analysis of bladder cancer tissues using Fourier transform infrared spectroscopy
    Nafie A. Al-Muslet
    Essam E. Ali
    Journal of Applied Spectroscopy, 2012, 79 : 139 - 142
  • [34] Analysis of temporomandibular joint synovial fluid using Fourier transform/infrared spectroscopy
    Ziegler, CM
    Kircher, P
    Hassfeld, S
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 60 (11) : 1302 - 1306
  • [35] A COMPARISON OF AMMONIA MEASUREMENTS USING FOURIER TRANSFORM INFRARED AND TUNEABLE DIODE LASER SPECTROSCOPY
    Li, Nilton
    El-Hamalawi, Ashraf
    Barrett, Richard
    Wheatley, Andrew
    Robinson, Jonathan
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2016, VOL. 2, 2016,
  • [36] Gallstone analysis using Fourier transform infrared spectroscopy (FT-IR)
    Yoo, Eun-Hyung
    Oh, Hyeon-Ju
    Lee, Soo-Youn
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (03) : 376 - 381
  • [37] Analysis of lard in meatball broth using Fourier transform infrared spectroscopy and chemometrics
    Kurniawati, Endah
    Rohman, Abdul
    Triyana, Kuwat
    MEAT SCIENCE, 2014, 96 (01) : 94 - 98
  • [38] SPECTROSCOPIC ANALYSIS OF BLADDER CANCER TISSUES USING FOURIER TRANSFORM INFRARED SPECTROSCOPY
    Al-Muslet, Nafie A.
    Ali, Essam E.
    JOURNAL OF APPLIED SPECTROSCOPY, 2012, 79 (01) : 139 - 142
  • [39] FOURIER-TRANSFORM INFRARED (FTIR) OF AQUEOUS-SOLUTIONS OF PROTEINS
    WINTERS, S
    GENDREAU, RM
    LEININGER, RI
    JAKOBSEN, RJ
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 289 : 183 - 183
  • [40] FOURIER-TRANSFORM INFRARED INVESTIGATION OF CARBOHYDRATES IN AQUEOUS-SOLUTIONS
    BACK, DM
    POLAVARAPU, PL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1985, 189 (APR-): : 5 - CARB