An interlaboratory comparison of sample presentation methods for the analysis of aqueous solutions using Fourier transform infrared spectroscopy

被引:0
|
作者
Bartl, F
Delgadillo, I
Davies, AN
Huvenne, JP
Meurens, M
Volka, K
Wilson, RH
机构
[1] INST FOOD RES, INST PHYS CHEM, NORWICH NR4 7UA, NORFOLK, ENGLAND
[2] UNIV MUNICH, DEPT QUIM, D-80333 MUNICH, GERMANY
[3] UNIV AVEIRO, P-3800 AVEIRO, PORTUGAL
[4] INST SPEKTROCHEM, CNRS, D-44013 DORTMUND, GERMANY
[5] SPECTROCHIM INFRAROUGE & RAMAN LAB, F-59655 VILLENEUVE DASCQ, FRANCE
[6] UNIV CATHOLIQUE LOUVAIN, DEPT ANALYT CHEM, B-1348 LOUVAIN, BELGIUM
[7] INST CHEM TECHNOL, CR-16628 PRAGUE 6, CZECH REPUBLIC
来源
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fourier transform infrared (FTIR) spectroscopy is becoming much more widely used as an analytical technique. It appears to be particularly useful for quantitative analysis, especially of aqueous solutions. However, there is a considerable variation in the cost and quality of instrumentation as well as a large number of accessories for sample presentation employing attenuated total reflectance (ATR). The objectives of the work reported in this paper were to investigate the effect of the choice of instrumentation on the quality of quantitative analyses as well as the effect of variable acquisition parameters. A series of experiments was designed in which samples were distributed to a number of workers using a range of FTIR instruments from different manufacturers and of differing quality. The workers were allowed to use the accessory of their own choice and to carry out a quantitative analysis of glucose solutions using their normal operating parameters. In following experiments the effects of instrumental and purge were considered and quantitative analysis was performed using a set of prescribed acquisition conditions. The results showed that there were significant differences in the quality of the spectra produced on the different combinations. However, although each worker produced quite different linear calibrations (in terms of slope and intercept), they all predicted the concentration of an unknown with a similar accuracy. However,later experiments showed that the low-cost bench-top instruments were not always so successful when the peaks used in the analysis were affected by residual water vapour interferences. Instrumental drift was noticeably worse for the low-cost instruments but this was an effect that could easily be eliminated by suitable baseline correction.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [21] FOURIER-TRANSFORM INFRARED-SPECTROSCOPY AS A POWERFUL TOOL FOR THE STUDY OF CARBOHYDRATES IN AQUEOUS-SOLUTIONS
    BACK, DM
    MICHALSKA, DF
    POLAVARAPU, PL
    APPLIED SPECTROSCOPY, 1984, 38 (02) : 173 - 180
  • [22] Methods to characterize the crystal polymorphs of polyvinylidene fluoride using Fourier transform infrared spectroscopy
    Mireja, Shubham
    Khakhar, Devang V. V.
    POLYMER ENGINEERING AND SCIENCE, 2023, 63 (09): : 2857 - 2870
  • [23] Authentication of edible oils using Fourier transform infrared spectroscopy and pattern recognition methods
    Sota-Uba, Isio
    Bamidele, Matthew
    Moulton, James
    Booksh, Karl
    Lavine, Barry K.
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2021, 210
  • [24] Rapid Assessment of Lipidomics Sample Purity and Quantity Using Fourier-Transform Infrared Spectroscopy
    Robinson, Harley
    Molendijk, Jeffrey
    Shah, Alok K.
    Rahman, Tony
    Anderson, Gregory J.
    Hill, Michelle M.
    BIOMOLECULES, 2022, 12 (09)
  • [25] Preparation of dimethoxyborane and analysis by Fourier transform infrared spectroscopy
    Bernas, Andreas
    Peltopakka, Birgitta
    Maki-Arvela, Paivi
    Eranen, Kari
    Salmi, Tapio
    Murzin, Dmitry Yu.
    RESEARCH ON CHEMICAL INTERMEDIATES, 2007, 33 (07) : 645 - 654
  • [26] Advances in Fourier transform infrared spectroscopy of natural glasses: From sample preparation to data analysis
    von Aulock, F. W.
    Kennedy, B. M.
    Schipper, C. I.
    Castro, J. M.
    Martin, D. E.
    Oze, C.
    Watkins, J. M.
    Wallace, P. J.
    Puskar, L.
    Begue, F.
    Nichols, A. R. L.
    Tuffen, H.
    LITHOS, 2014, 206 : 52 - 64
  • [27] Analysis of adulteration in honey with standard sugar solutions and syrups using attenuated total reflectance-Fourier transform infrared spectroscopy and multivariate methods
    Rios-Corripio, M. A.
    Rojas-Lopez, M.
    Delgado-Macuil, R.
    CYTA-JOURNAL OF FOOD, 2012, 10 (02) : 119 - 122
  • [28] Preparation of dimethoxyborane and analysis by Fourier transform infrared spectroscopy
    Andreas Bernas
    Birgitta Peltopakka
    Päivi Mäki-Arvela
    Kari Eränen
    Tapio Salmi
    Dmitry Yu. Murzin
    Research on Chemical Intermediates, 2007, 33 : 645 - 654
  • [29] Fourier transform infrared spectroscopy for analysis of kidney stones
    Khan, Aysha Habib
    Imran, Sheharbano
    Talati, Jamsheer
    Jafri, Lena
    INVESTIGATIVE AND CLINICAL UROLOGY, 2018, 59 (01) : 32 - 37
  • [30] Fourier transform infrared spectroscopy in analysis of protein deposits
    Seshadri, S
    Khurana, R
    Fink, AL
    AMYLOID, PRIONS, AND OTHER PROTEIN AGGREGATES, 1999, 309 : 559 - 576