An interlaboratory comparison of sample presentation methods for the analysis of aqueous solutions using Fourier transform infrared spectroscopy

被引:0
|
作者
Bartl, F
Delgadillo, I
Davies, AN
Huvenne, JP
Meurens, M
Volka, K
Wilson, RH
机构
[1] INST FOOD RES, INST PHYS CHEM, NORWICH NR4 7UA, NORFOLK, ENGLAND
[2] UNIV MUNICH, DEPT QUIM, D-80333 MUNICH, GERMANY
[3] UNIV AVEIRO, P-3800 AVEIRO, PORTUGAL
[4] INST SPEKTROCHEM, CNRS, D-44013 DORTMUND, GERMANY
[5] SPECTROCHIM INFRAROUGE & RAMAN LAB, F-59655 VILLENEUVE DASCQ, FRANCE
[6] UNIV CATHOLIQUE LOUVAIN, DEPT ANALYT CHEM, B-1348 LOUVAIN, BELGIUM
[7] INST CHEM TECHNOL, CR-16628 PRAGUE 6, CZECH REPUBLIC
来源
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fourier transform infrared (FTIR) spectroscopy is becoming much more widely used as an analytical technique. It appears to be particularly useful for quantitative analysis, especially of aqueous solutions. However, there is a considerable variation in the cost and quality of instrumentation as well as a large number of accessories for sample presentation employing attenuated total reflectance (ATR). The objectives of the work reported in this paper were to investigate the effect of the choice of instrumentation on the quality of quantitative analyses as well as the effect of variable acquisition parameters. A series of experiments was designed in which samples were distributed to a number of workers using a range of FTIR instruments from different manufacturers and of differing quality. The workers were allowed to use the accessory of their own choice and to carry out a quantitative analysis of glucose solutions using their normal operating parameters. In following experiments the effects of instrumental and purge were considered and quantitative analysis was performed using a set of prescribed acquisition conditions. The results showed that there were significant differences in the quality of the spectra produced on the different combinations. However, although each worker produced quite different linear calibrations (in terms of slope and intercept), they all predicted the concentration of an unknown with a similar accuracy. However,later experiments showed that the low-cost bench-top instruments were not always so successful when the peaks used in the analysis were affected by residual water vapour interferences. Instrumental drift was noticeably worse for the low-cost instruments but this was an effect that could easily be eliminated by suitable baseline correction.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [1] Fourier transform infrared spectroscopy of aqueous solutions using optical subtraction
    Jensen, PS
    Bak, J
    Andersen, PE
    Andersson-Engels, S
    OPTICAL DIAGNOSTICS AND SENSING OF BIOLOGICAL FLUIDS AND GLUCOSE AND CHOLESTEROL MONITORING II, 2002, 4624 : 150 - 159
  • [2] MEASUREMENT OF INFRARED-SPECTRA OF AQUEOUS-SOLUTIONS USING FOURIER-TRANSFORM SPECTROSCOPY
    LOW, MJD
    YANG, RT
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1973, A 29 (10) : 1761 - 1772
  • [3] PAINT SAMPLE PRESENTATION FOR FOURIER-TRANSFORM INFRARED MICROSCOPY
    ALLEN, TJ
    VIBRATIONAL SPECTROSCOPY, 1992, 3 (03) : 217 - 237
  • [4] APPLICATION OF FOURIER-TRANSFORM INFRARED-SPECTROSCOPY TO STUDIES OF AQUEOUS PROTEIN SOLUTIONS
    ZUBER, G
    PRESTRELSKI, SJ
    BENEDEK, K
    ANALYTICAL BIOCHEMISTRY, 1992, 207 (01) : 150 - 156
  • [5] ANALYSIS OF MENISCUS USING FOURIER TRANSFORM INFRARED IMAGING SPECTROSCOPY
    Kuroki, H.
    Tsuchimoto, K.
    Kobayashi-Miura, M.
    Aoyama, T.
    Ito, A.
    Hashimoto, K.
    Ishibashi, M.
    Yamaguchi, S.
    Zhang, X. K.
    OSTEOARTHRITIS AND CARTILAGE, 2011, 19 : S204 - S205
  • [6] Prediction of α-Lactalbumin and β-Lactoglobulin Composition of Aqueous Whey Solutions Using Fourier Transform Mid-Infrared Spectroscopy and Near-Infrared Spectroscopy
    Tonolini, Margherita
    Sorensen, Klavs Martin
    Skou, Peter B.
    Ray, Colin
    Engelsen, Soren Balling
    APPLIED SPECTROSCOPY, 2021, 75 (06) : 718 - 727
  • [7] Comparison of emissivity retrieval methods from ASTER data using Fourier-Transform Infrared Spectroscopy
    Silvia Beatriz Alves Rolim
    Bijeesh Kozhikkodan Veettil
    Pâmela Suélen Käfer
    Atilio Efrain Bica Grondona
    María Luján Iglesias
    Lucas Ribeiro Diaz
    Cristiano Lima Hackmann
    Acta Geophysica, 2020, 68 : 1867 - 1876
  • [8] Comparison of emissivity retrieval methods from ASTER data using Fourier-Transform Infrared Spectroscopy
    Rolim, Silvia Beatriz Alves
    Veettil, Bijeesh Kozhikkodan
    Kafer, Pamela Suelen
    Grondona, Atilio Efrain Bica
    Iglesias, Maria Lujan
    Diaz, Lucas Ribeiro
    Hackmann, Cristiano Lima
    ACTA GEOPHYSICA, 2020, 68 (06) : 1867 - 1876
  • [9] THE ANALYSIS OF ISOBUTANE OXIDATION USING FOURIER TRANSFORM-INFRARED SPECTROSCOPY
    MCCORMICK, TW
    MILLER, DL
    CERNANSKY, NP
    SPECTROSCOPY, 1995, 10 (03) : 26 - 31
  • [10] Quantitative gas analysis using Fourier transform infrared spectroscopy method
    Key Lab. of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China
    不详
    Yi Qi Yi Biao Xue Bao, 2007, 1 (80-84):