Carrier accumulation and depletion in point-contact capacitance-voltage measurements

被引:2
|
作者
Naitou, Yuichi [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Nanoelect Res Inst, 1-1-1 Higashi, Tsukuba, Ibaraki 3058562, Japan
来源
AIP ADVANCES | 2017年 / 7卷 / 11期
关键词
ALL-METAL PROBE; MICROSCOPY;
D O I
10.1063/1.5005861
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Scanning capacitance microscopy (SCM) is a variation of atomic force microscopy in which a conductive probe tip detects the bias modulated capacitance for the purpose of measuring the nanoscale semiconductor carrier concentration. SCM can be regarded as a point-contact capacitance-voltage system, and its capacitance-voltage properties are different from those of a conventional parallel-plate capacitor. In this study, the charge accumulation and depletion behavior of a semiconductor sample were closely investigated by SCM. By analyzing the tip-sample approach curve, the effective probe tip area and charge depletion depth could be quantitatively determined. (C) 2017 Author(s).
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Photoelectrochemical capacitance-voltage measurements of 4H-SiC
    Stutz, CE
    [J]. JOURNAL OF ELECTRONIC MATERIALS, 1998, 27 (12) : L81 - L83
  • [22] Thin oxide thickness extrapolation from capacitance-voltage measurements
    Walstra, SV
    Sah, CT
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 1997, 44 (07) : 1136 - 1142
  • [23] Investigation of hexagonal microtube ZnO on silicon by capacitance-voltage measurements
    Sun, YS
    Liu, N
    Zhou, X
    Deng, H
    Gao, H
    Wu, HJ
    Li, YR
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2006, 24 (02): : 246 - 249
  • [24] Photoelectrochemical capacitance-voltage measurements of 4H-SiC
    C. E. Stutz
    [J]. Journal of Electronic Materials, 1998, 27 : L81 - L83
  • [25] EFFECT OF BACK CONTACT IMPEDANCE ON FREQUENCY-DEPENDENCE OF CAPACITANCE-VOLTAGE MEASUREMENTS ON METAL DIAMOND DIODES
    VENKATESAN, V
    DAS, K
    VONWINDHEIM, JA
    GEIS, MW
    [J]. APPLIED PHYSICS LETTERS, 1993, 63 (08) : 1065 - 1067
  • [26] DOPING PROFILE ANALYSIS IN SI BY ELECTROCHEMICAL CAPACITANCE-VOLTAGE MEASUREMENTS
    PEINER, E
    SCHLACHETZKI, A
    KRUGER, D
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1995, 142 (02) : 576 - 580
  • [27] Role of Injection Barrier in Capacitance-Voltage Measurements of Organic Devices
    Nigam, Akash
    Nair, Pradeep R.
    Premaratne, Malin
    Rao, V. Ramgopal
    [J]. IEEE ELECTRON DEVICE LETTERS, 2014, 35 (05) : 581 - 583
  • [28] Lateral Capacitance-Voltage Method of NanoMOSFET for Detecting the Hot Carrier Injection
    Atamuratov, Atabek E.
    Yusupov, Ahmed
    Atamuratova, Zukhra A.
    Chedjou, Jean Chamberlain
    Kyamakya, Kyandoghere
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (21): : 1 - 9
  • [29] Direct extraction of carrier mobility in graphene field-effect transistor using current-voltage and capacitance-voltage measurements
    Zhang, Zhiyong
    Xu, Huilong
    Zhong, Hua
    Peng, Lian-Mao
    [J]. APPLIED PHYSICS LETTERS, 2012, 101 (21)
  • [30] Electrochemical capacitance-voltage profiling of heterostructures using small contact areas
    Sell, B
    Gatzke, C
    Fernandez, JM
    [J]. SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 1998, 13 (04) : 423 - 427