Comparative accuracy of optical sensor-based wearable system for non-invasive measurement of blood glucose concentration

被引:21
|
作者
Rodin, Dmitry [1 ]
Kirby, Michael [1 ]
Sedogin, Natallia [3 ]
Shapiro, Yair [2 ]
Pinhasov, Albert [1 ]
Kreinin, Anatoly [3 ]
机构
[1] Ariel Univ, Dept Mol Biol, Ariel, Israel
[2] Ariel Univ, Dept Hlth Syst Management, Ariel, Israel
[3] Bruce Rappaport Med Fac, Maale Carmel Mental Hlth Ctr, Technion, Tirat Carmel, Israel
关键词
Diabetes; Glucose level; Non-invasive glucometry; Optical biosensor;
D O I
10.1016/j.clinbiochem.2018.12.014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Non-invasive biosensors for indirect evaluation of routinely-measured blood components by sweat analysis have broad potential clinical applications. This trial tested a wrist-borne non-invasive glucose monitor (NIGM) to measure blood glucose (BG) levels using photoplethysmographic (PPG) optical sensors. Our aim was to determine the accuracy of the device in comparison with a standard, invasive clinical method for blood glucose monitoring. Adult participants (n = 200) of both sexes from 18 to 75 were recruited for the study. Exclusion criteria: hemophilia and other serious coagulation disorders, impaired venous access, other serious medical conditions. A biosensor was placed on the right wrist of each participant for a non-invasive indirect BG measurement. In parallel, blood from the antecubital vein was collected and glucose levels were assessed with YSI 2300 Bioanalyzer. The measurements were performed twice: before and after food intake, with a 1-h interval between measurements. There were no limitations to food type and quantity. In both anteprandial (rho = 0.8994, p < 0.0001) and postprandial (rho = 0.9382, p < 0.0001) glucose measurements, NIGM correlated with values obtained by the YSI 2300 reference device - there was no significant difference between the two methods. Plotted on a Parkes Error Grid for Type II diabetes, NIGM readings did not deviate from those of the YSI 2300 in any clinically-significant way, with the majority of correlated readings falling within Parkes zone A. Very few readings fell within Parkes zone B. In anteprandial measurements, the mean bias between methods for all patient volunteers was 3.705 +/- 7.838. In postprandial measurements gave a mean bias of 1.362 +/- 10.15 for all patient glucose data. The mean absolute relative difference of currently available glucometer models ranges from 5.6% to 20.8%. The NIGM falls in the lower end of this error range at 7.40-7.54%, indicating that PPG-chemochrome sensors are capable of producing results comparable with those of direct measure glucometers. Data presented here demonstrates the reliability and accuracy of the NIGM system as an adjunctive, and perhaps substitutive, non-invasive tool for blood glucose monitoring.
引用
收藏
页码:15 / 20
页数:6
相关论文
共 50 条
  • [41] Temperature influence on non-invasive blood glucose measurement
    Zhang, Xiqin
    Yeo, Joon Hock
    [J]. OPTICAL DIAGNOSTICS AND SENSING IX, 2009, 7186
  • [42] A non-invasive microcontroller based estimation of blood glucose concentration by using a modified capacitive sensor at low frequency
    Dutta, Abhinaba
    Bera, Satish Chandra
    Das, Kamalesh
    [J]. AIP ADVANCES, 2019, 9 (10)
  • [43] Adaptive Boosting Based Personalized Glucose Monitoring System (PGMS) for Non-Invasive Blood Glucose Prediction with Improved Accuracy
    Anand, Pradeep Kumar
    Shin, Dong Ryeol
    Memon, Mudasar Latif
    [J]. DIAGNOSTICS, 2020, 10 (05)
  • [44] Research on Non-invasive Glucose Concentration Measurement by NIR Transmission
    Li, Xiaoli
    Li, Chengwei
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTER AND COMMUNICATIONS (ICCC), 2015, : 223 - 228
  • [45] Non-Invasive Monitoring of Blood Glucose by Means of Wearable Tracking Technology
    Kascheev, Nikolay
    Kozyrev, Oleg
    Leykin, Maxim
    Vanyagin, Alexey
    [J]. 2017 IEEE EAST-WEST DESIGN & TEST SYMPOSIUM (EWDTS), 2017,
  • [46] Design of a Non-invasive ECG-based Glucose Measurement System
    Gusev, M.
    Guseva, E.
    Poposka, L.
    [J]. 2020 43RD INTERNATIONAL CONVENTION ON INFORMATION, COMMUNICATION AND ELECTRONIC TECHNOLOGY (MIPRO 2020), 2020, : 303 - 308
  • [47] Near-infrared LED based Non-invasive Blood Glucose Sensor
    Yadav, Jyoti
    Rani, Asha
    Singh, Vijander
    Murari, Bhaskar Mohan
    [J]. 2014 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND INTEGRATED NETWORKS (SPIN), 2014, : 591 - 594
  • [48] Wearable non-invasive glucose sensors based on metallic nanomaterials
    Zhang, Sheng
    Zhao, Wenjie
    Zeng, Junyan
    He, Zhaotao
    Wang, Xiang
    Zhu, Zehui
    Hu, Runqing
    Liu, Chen
    Wang, Qianqian
    [J]. MATERIALS TODAY BIO, 2023, 20
  • [49] Electro-enzymatic sensor for non-invasive glucose measurement
    Patel, Jasbir N.
    Gray, Bonnie
    Kaminska, Bozena
    Gates, Byron
    [J]. 2007 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-3, 2007, : 421 - 424
  • [50] Study on Non-invasive Optical Detection of the Glucose Concentration with Scatters
    Lin, Li-Han
    Liao, Chia-Chi
    Lo, Yu-Lung
    [J]. INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS 2014, 2015, 9302