Comparative accuracy of optical sensor-based wearable system for non-invasive measurement of blood glucose concentration

被引:21
|
作者
Rodin, Dmitry [1 ]
Kirby, Michael [1 ]
Sedogin, Natallia [3 ]
Shapiro, Yair [2 ]
Pinhasov, Albert [1 ]
Kreinin, Anatoly [3 ]
机构
[1] Ariel Univ, Dept Mol Biol, Ariel, Israel
[2] Ariel Univ, Dept Hlth Syst Management, Ariel, Israel
[3] Bruce Rappaport Med Fac, Maale Carmel Mental Hlth Ctr, Technion, Tirat Carmel, Israel
关键词
Diabetes; Glucose level; Non-invasive glucometry; Optical biosensor;
D O I
10.1016/j.clinbiochem.2018.12.014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Non-invasive biosensors for indirect evaluation of routinely-measured blood components by sweat analysis have broad potential clinical applications. This trial tested a wrist-borne non-invasive glucose monitor (NIGM) to measure blood glucose (BG) levels using photoplethysmographic (PPG) optical sensors. Our aim was to determine the accuracy of the device in comparison with a standard, invasive clinical method for blood glucose monitoring. Adult participants (n = 200) of both sexes from 18 to 75 were recruited for the study. Exclusion criteria: hemophilia and other serious coagulation disorders, impaired venous access, other serious medical conditions. A biosensor was placed on the right wrist of each participant for a non-invasive indirect BG measurement. In parallel, blood from the antecubital vein was collected and glucose levels were assessed with YSI 2300 Bioanalyzer. The measurements were performed twice: before and after food intake, with a 1-h interval between measurements. There were no limitations to food type and quantity. In both anteprandial (rho = 0.8994, p < 0.0001) and postprandial (rho = 0.9382, p < 0.0001) glucose measurements, NIGM correlated with values obtained by the YSI 2300 reference device - there was no significant difference between the two methods. Plotted on a Parkes Error Grid for Type II diabetes, NIGM readings did not deviate from those of the YSI 2300 in any clinically-significant way, with the majority of correlated readings falling within Parkes zone A. Very few readings fell within Parkes zone B. In anteprandial measurements, the mean bias between methods for all patient volunteers was 3.705 +/- 7.838. In postprandial measurements gave a mean bias of 1.362 +/- 10.15 for all patient glucose data. The mean absolute relative difference of currently available glucometer models ranges from 5.6% to 20.8%. The NIGM falls in the lower end of this error range at 7.40-7.54%, indicating that PPG-chemochrome sensors are capable of producing results comparable with those of direct measure glucometers. Data presented here demonstrates the reliability and accuracy of the NIGM system as an adjunctive, and perhaps substitutive, non-invasive tool for blood glucose monitoring.
引用
收藏
页码:15 / 20
页数:6
相关论文
共 50 条
  • [1] Skin Impedance Measurement in Wearable Non-invasive Optical Blood Glucose Monitors
    Li, C.K.
    Tsai, Chih Wei
    [J]. 2020 2nd IEEE International Workshop on System Biology and Biomedical Systems, SBBS 2020, 2020,
  • [2] Skin Impedance Measurement in Wearable Non-invasive Optical Blood Glucose Monitors
    Li, C. K.
    Tsai, Chih Wei
    [J]. 2020 2ND IEEE INTERNATIONAL WORKSHOP ON SYSTEM BIOLOGY AND BIOMEDICAL SYSTEMS (SBBS), 2020,
  • [3] Wearable non-invasive blood glucose monitor system based on galvanic skin resistance measurement
    Donelli, Massimo
    Espa, Giuseppe
    Feraco, Paola
    Manekiya, Mohammedhusen
    [J]. ELECTRONICS LETTERS, 2021, 57 (24) : 901 - 902
  • [4] LED Based Sensor System for Non-Invasive Measurement of the Hemoglobin Concentration in Human Blood
    Timm, U.
    Lewis, E.
    McGrath, D.
    Kraitl, J.
    Ewald, H.
    [J]. 13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 825 - +
  • [5] Non-invasive Blood Glucose Measurement System
    Deepthi, S.
    Valke, Nikita S.
    Parvathy, J. P.
    Sai, Anjaly Krishna
    Sajjan, Guttappa
    [J]. 2019 5TH IEEE INTERNATIONAL WIE CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (WIECON-ECE 2019), 2019,
  • [6] Non-invasive Blood Glucose Estimation Using Multi-sensor Based Portable and Wearable System
    Mahmud, Tasfin
    Limon, Mehedi Hossen
    Ahmed, Sabbir
    Rafi, Mohammad Zunaed
    Ahamed, Borhan
    Nitol, Shadman Shahriar
    Mia, Md Yeasin
    Choudhury, Rafat Emtiaz
    Sakib, Adnan
    Subhana, Arik
    Shahnaz, Celia
    [J]. 2019 IEEE GLOBAL HUMANITARIAN TECHNOLOGY CONFERENCE (GHTC), 2019, : 438 - 442
  • [7] Sensor Calibration Models for a Non-Invasive Blood Glucose Measurement Sensor
    Stemmann, M.
    Stahl, F.
    Lallemand, J.
    Renard, E.
    Johansson, R.
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4979 - 4982
  • [8] An IoMT based Non-Invasive Precise Blood Glucose Measurement System
    Jain, Prateek
    Pancholi, Sidharth
    Joshi, Amit M.
    [J]. 2019 IEEE INTERNATIONAL SYMPOSIUM ON SMART ELECTRONIC SYSTEMS (ISES 2019), 2019, : 111 - 116
  • [9] Non-Invasive Blood Components Measurement Using Optical Sensor System Interface
    Raikham, Pamshangphy
    Kumar, Rohit
    Shah, Rahul Kumar
    Hazarika, Mery
    Sonkar, R. K.
    [J]. 2018 3RD INTERNATIONAL CONFERENCE ON MICROWAVE AND PHOTONICS (ICMAP), 2018,
  • [10] OPTICAL SENSOR SYSTEM FOR NON-INVASIVE BLOOD DIAGNOSIS
    Timm, U.
    Lewis, E.
    McGrath, D.
    Kraitl, J.
    Ewald, H.
    [J]. SAS 2009 - IEEE SENSORS APPLICATIONS SYMPOSIUM, PROCEEDINGS, 2009, : 210 - +