Evaluation of spatial resolution in image acquisition by optical flatbed scanners for radiochromic film dosimetry

被引:7
|
作者
Asero, G. [1 ,2 ]
Greco, C. [3 ,4 ]
Gueli, A. M. [1 ,2 ,4 ]
Raffaele, L. [3 ,4 ]
Spampinato, S. [1 ,2 ,4 ]
机构
[1] Univ Catania, Dipartimento Fis & Astron, PH3DRA Labs PHys Dating Diagnost Dosimetry Res &, Via Santa Sofia 64, I-95123 Catania, Italy
[2] Ist Nazl Fis Nucl, Via Santa Sofia 64, I-95123 Catania, Italy
[3] Azienda Osped Univ Policlin Vittorio Emanuele, Via Santa Sofia 78, I-95123 Catania, Italy
[4] Univ Catania, Scuola Fac Med, Dipartimento Sci Med Chirurg & Tecnol Avanzate GF, Scuola Specializzaz Fis Med, Via Santa Sofia 78, I-95123 Catania, Italy
来源
关键词
Image reconstruction in medical imaging; Data processing methods; Dosimetry concepts and apparatus; X-ray radiography and digital radiography (DR); XR TYPE-T; ENERGY RESPONSE;
D O I
10.1088/1748-0221/11/03/P03024
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Introduction: Radiochromic films are two-dimensional dosimeters that do not require developing and give values of absorbed dose with accuracy and precision. Since this dosimeter colours directly after irradiation, it can be digitized with commercial optical flatbed scanners to obtain a calibration curve that links blackening of the film with dose. Although the film has an intrinsic high spatial resolution, the scanner determines the actual resolution of this dosimeter, in particular the "dot per inch" (dpi) parameter. The present study investigates the effective spatial resolution of a scanner used for Gafchromic (R) XR-QA2 film (designed for radiology Quality Assurance) analysis. Material and methods: The quantitative evaluation of the resolution was performed with the Modulation Transfer Function (MTF) method, comparing the nominal resolution with the experimental one. The analysis was performed with two procedures. First, the 1951 USAF resolution test chart, a tool that tests the performance of optical devices, was used. Secondly, a combined system of mammography X-ray tube, XR-QA2 film and a bar pattern object was used. In both cases the MTF method has been applied and the results were compared. Results: The USAF and the film images have been acquired with increasing dpi and a standard protocol for radiochromic analysis, to evaluate horizontal and vertical and resolution. The effective resolution corresponds to the value of the MTF at 50%. In both cases and for both procedures, it was verified that, starting from a dpi value, the effective resolution saturates. Conclusion: The study found that, for dosimetric applications, the dpi of the scanner have to be adjusted to a reasonable value because, if too high, it requires high scanning and computational time without providing additional information.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC® film
    Lynch, Bart D.
    Kozelka, Jakub
    Ranade, Manisha K.
    Li, Jonathan G.
    Simon, William E.
    Dempsey, James F.
    MEDICAL PHYSICS, 2006, 33 (12) : 4551 - 4556
  • [2] Correcting lateral response artifacts from flatbed scanners for radiochromic film dosimetry
    Lewis, David
    Chan, Maria F.
    MEDICAL PHYSICS, 2015, 42 (01) : 416 - 429
  • [3] An Optical Investigation Into the Polarization and Scattering Effects Underlying the Artifacts of Radiochromic Film Dosimetry with Commercial Flatbed Scanners
    Schoenfeld, A.
    Poppinga, D.
    Harder, D.
    Doerner, K.
    Poppe, B.
    MEDICAL PHYSICS, 2014, 41 (06) : 230 - +
  • [4] Flatbed scanner stability for radiochromic film dosimetry
    Laosa, C.
    Calvo Ortega, J. F.
    Moragues Femenia, S.
    Casals, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S910 - S910
  • [5] A new correction method serving to eliminate the parabola effect of flatbed scanners used in radiochromic film dosimetry
    Poppinga, D.
    Schoenfeld, A. A.
    Doerner, K. J.
    Blanck, O.
    Harder, D.
    Poppe, B.
    MEDICAL PHYSICS, 2014, 41 (02) : 021707
  • [6] Correction of lateral response artifacts from flatbed scanners for dual-channel radiochromic film dosimetry
    Akino, Yuichi
    Shiomi, Hiroya
    Isohashi, Fumiaki
    Suzuki, Osamu
    Seo, Yuji
    Tamari, Keisuke
    Hirata, Takero
    Mizuno, Hirokazu
    Ogawa, Kazuhiko
    JOURNAL OF RADIATION RESEARCH, 2021, 62 (02) : 319 - 328
  • [7] Radiochromic film dosimetry with flatbed scanners: A fast and accurate method for dose calibration and uniformity correction with single film exposure
    Menegotti, L.
    Delana, A.
    Martignano, A.
    MEDICAL PHYSICS, 2008, 35 (07) : 3078 - 3085
  • [8] RADIOCHROMIC FILM DOSIMETRY WITH FLATBED SCANNERS: A FAST AND ACCURATE METHOD FOR DOSE CALIBRATION AND UNIFORMITY CORRECTION WITH SINGLE FILM EXPOSURE
    Menegotti, L.
    Delana, A.
    Vanoni, V.
    Martignano, A.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S391 - S391
  • [9] How flatbed scanners upset accurate film dosimetry
    van Battum, L. J.
    Huizenga, H.
    Verdaasdonk, R. M.
    Heukelom, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02): : 625 - 649
  • [10] Investigation of Commercial-Grade Flatbed Scanners and a Medical-Grade Scanner for Radiochromic EBT Film Dosimetry
    Syh, J.
    Patel, B.
    Syh, J.
    Wu, H.
    Rosen, L.
    Durci, M.
    Katz, S.
    Sibata, C.
    MEDICAL PHYSICS, 2012, 39 (06) : 3734 - 3734