2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series

被引:93
|
作者
Gras, Florian [1 ]
Marintschev, Ivan [1 ]
Wilharm, Arne [1 ]
Klos, Kajetan [1 ]
Mueckley, Thomas [1 ]
Hofmann, Gunther O. [1 ,2 ]
机构
[1] Univ Jena, Dept Trauma Hand & Reconstruct Surg, D-6900 Jena, Germany
[2] Berufsgenossenschaftl Kliniken Halle, Halle, Germany
来源
关键词
ILIOSACRAL SCREWS; INTERNAL-FIXATION; FRACTURE-DISLOCATIONS; SACROILIAC SCREWS; SUPINE POSITION; PLACEMENT; STABILIZATION; DISRUPTIONS; FLUOROSCOPY; INSERTION;
D O I
10.1186/1471-2474-11-153
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Screw fixation of pelvic ring fractures is a common, but demanding procedure and navigation techniques were introduced to increase the precision of screw placement. The purpose of this case series was the evaluation of screw misplacement rate and functional outcome of percutaneous screw fixation of pelvic ring disruptions using a 2D navigation system. Methods: Between August 2004 and December 2007, 44 of 442 patients with pelvic injuries were included for closed reduction and percutaneous screw fixation of disrupted pelvic ring lesions using an optoelectronic 2D-fluoroscopic based navigation system. Operating and fluoroscopy time were measured, as well as peri- and postoperative complications documented. Screw position was assessed by postoperative CT scans. Quality of live was evaluated by SF 36-questionnaire in 40 of 44 patients at mean follow up 15.5 +/- 1.2 month. Results: 56 iliosacral- and 29 ramus pubic-screws were inserted ( mean operation time per screw 62 +/- 4 minutes, mean fluoroscopy time per screw 123 +/- 12 seconds). In post-operative CT-scans the screw position was assessed and graded as follows: I. secure positioning, completely in the cancellous bone (80%); II. secure positioning, but contacting cortical bone structures (14%); III. malplaced positioning, penetrating the cortical bone (6%). The malplacements predominantly occurred in bilateral overlapping screw fixation. No wound infection or iatrogenic neurovascular damage were observed. Four re-operations were performed, two of them due to implant-misplacement and two of them due to implant-failure. Conclusion: 2D-fluoroscopic navigation is a safe tool providing high accuracy of percutaneous screw placement for pelvic ring fractures, but in cases of a bilateral iliosacral screw fixation an increased risk for screw misplacement was observed. If additional ramus pubic screw fixations are performed, the retrograde inserted screws have to pass the iliopubic eminence to prevent an axial screw loosening.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Percutaneous Iliosacral Screw Fixation for fractures and disruptions of the posterior pelvic ring - technique and perioperative complications
    Osterhoff, Georg
    Ossendorf, Christian
    Wanner, Guido A.
    Simmen, Hans-Peter
    Werner, Clement M.
    SWISS MEDICAL WEEKLY, 2010, 140 (23-24) : 6S - 6S
  • [42] Percutaneous iliosacral screw fixation for fractures and disruptions of the posterior pelvic ring - technique and perioperative complications
    Osterhoff, G.
    Ossendorf, C.
    Wanner, G. A.
    Simmen, H. -P.
    Werner, C. M.
    BRITISH JOURNAL OF SURGERY, 2010, 97 : 17 - 17
  • [43] A screw view model of navigation guided minimal invasive percutaneous pelvic screws insertion for lateral compression pelvic ring injuries A case report
    Yuan, Bao-Ming
    Huang, Ge
    Zheng, Shuang
    Yu, Tong
    Zhao, Jian-Wu
    MEDICINE, 2020, 99 (40) : E21755
  • [44] Robot-assisted versus conventional percutaneous sacroiliac screw fixation for posterior pelvic ring injuries: a systematic review and meta-analysis
    Abdulrahman Al-Naseem
    Abdelrahman Sallam
    Ahmed Gonnah
    Omar Masoud
    Muhammad M. Abd-El-Barr
    Ilyas S. Aleem
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 9 - 20
  • [45] TiRobot-assisted versus conventional fluoroscopy-assisted percutaneous sacroiliac screw fixation for pelvic ring injuries: a meta-analysis
    Zhao, Chunpeng
    Zhu, Gang
    Wang, Yu
    Wu, Xinbao
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [46] Robot-assisted versus conventional percutaneous sacroiliac screw fixation for posterior pelvic ring injuries: a systematic review and meta-analysis
    Al-Naseem, Abdulrahman
    Sallam, Abdelrahman
    Gonnah, Ahmed
    Masoud, Omar
    Abd-El-Barr, Muhammad M.
    Aleem, Ilyas S.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (01): : 9 - 20
  • [47] FAILURE RATE OF TRANSSACRAL SCREW FIXATION IN POSTERIOR PELVIC RING INJURIES WITH ZONE II SACRAL FRACTURES
    Chambers, M.
    Ferguson, T.
    Min, W.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2013, 61 (01) : 195 - 196
  • [48] Is implant removal after percutaneous iliosacral screw fixation of unstable posterior pelvic ring disruptions indicated?
    Yücel, N
    Lefering, R
    Tjardes, T
    Korenkov, M
    Schierholz, J
    Tiling, T
    Bouillon, B
    Rixen, D
    UNFALLCHIRURG, 2004, 107 (06): : 468 - 474
  • [49] Posterior pelvic ring fractures: Closed reduction and percutaneous CT-guided sacroiliac screw fixation
    Augustinus Ludwig Jacob
    Peter Messmer
    Klaus-Wilhelm Stock
    Norbert Suhm
    Bernard Baumann
    Pietro Regazzoni
    Wolfgang Steinbrich
    CardioVascular and Interventional Radiology, 1997, 20 : 285 - 294
  • [50] Posterior pelvic ring fractures: Closed reduction and percutaneous CT-guided sacroiliac screw fixation
    Jacob, AL
    Messmer, P
    Stock, KW
    Suhm, N
    Baumann, B
    Regazzoni, P
    Steinbrich, W
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 20 (04) : 285 - 294