2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series

被引:93
|
作者
Gras, Florian [1 ]
Marintschev, Ivan [1 ]
Wilharm, Arne [1 ]
Klos, Kajetan [1 ]
Mueckley, Thomas [1 ]
Hofmann, Gunther O. [1 ,2 ]
机构
[1] Univ Jena, Dept Trauma Hand & Reconstruct Surg, D-6900 Jena, Germany
[2] Berufsgenossenschaftl Kliniken Halle, Halle, Germany
来源
关键词
ILIOSACRAL SCREWS; INTERNAL-FIXATION; FRACTURE-DISLOCATIONS; SACROILIAC SCREWS; SUPINE POSITION; PLACEMENT; STABILIZATION; DISRUPTIONS; FLUOROSCOPY; INSERTION;
D O I
10.1186/1471-2474-11-153
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Screw fixation of pelvic ring fractures is a common, but demanding procedure and navigation techniques were introduced to increase the precision of screw placement. The purpose of this case series was the evaluation of screw misplacement rate and functional outcome of percutaneous screw fixation of pelvic ring disruptions using a 2D navigation system. Methods: Between August 2004 and December 2007, 44 of 442 patients with pelvic injuries were included for closed reduction and percutaneous screw fixation of disrupted pelvic ring lesions using an optoelectronic 2D-fluoroscopic based navigation system. Operating and fluoroscopy time were measured, as well as peri- and postoperative complications documented. Screw position was assessed by postoperative CT scans. Quality of live was evaluated by SF 36-questionnaire in 40 of 44 patients at mean follow up 15.5 +/- 1.2 month. Results: 56 iliosacral- and 29 ramus pubic-screws were inserted ( mean operation time per screw 62 +/- 4 minutes, mean fluoroscopy time per screw 123 +/- 12 seconds). In post-operative CT-scans the screw position was assessed and graded as follows: I. secure positioning, completely in the cancellous bone (80%); II. secure positioning, but contacting cortical bone structures (14%); III. malplaced positioning, penetrating the cortical bone (6%). The malplacements predominantly occurred in bilateral overlapping screw fixation. No wound infection or iatrogenic neurovascular damage were observed. Four re-operations were performed, two of them due to implant-misplacement and two of them due to implant-failure. Conclusion: 2D-fluoroscopic navigation is a safe tool providing high accuracy of percutaneous screw placement for pelvic ring fractures, but in cases of a bilateral iliosacral screw fixation an increased risk for screw misplacement was observed. If additional ramus pubic screw fixations are performed, the retrograde inserted screws have to pass the iliopubic eminence to prevent an axial screw loosening.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Percutaneous iliosacral screw fixation in S1 and S2 for posterior pelvic ring injuries: technique and perioperative complications
    Georg Osterhoff
    Christian Ossendorf
    Guido A. Wanner
    Hans-Peter Simmen
    Clément M. L. Werner
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 809 - 813
  • [22] Complications of conventional percutaneous sacroiliac screw fixation of traumatic pelvic ring injuries: a systematic review and meta-analysis
    Osama Z. Alzobi
    Yahya Alborno
    Ahmad Toubasi
    Jawad Derbas
    Hammam Kayali
    Hazem Nasef
    Ashraf T. Hantouly
    Aiman Mudawi
    Shady Mahmoud
    Ghalib Ahmed
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 3107 - 3117
  • [23] Complications of conventional percutaneous sacroiliac screw fixation of traumatic pelvic ring injuries: a systematic review and meta-analysis
    Alzobi, Osama Z.
    Alborno, Yahya
    Toubasi, Ahmad
    Derbas, Jawad
    Kayali, Hammam
    Nasef, Hazem
    Hantouly, Ashraf T.
    Mudawi, Aiman
    Mahmoud, Shady
    Ahmed, Ghalib
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (07): : 3107 - 3117
  • [24] Functional outcome of unstable pelvic ring injuries after iliosacral screw fixation: single versus two screw fixation
    S. A. Khaled
    O. Soliman
    M. A. Wahed
    European Journal of Trauma and Emergency Surgery, 2015, 41 : 387 - 392
  • [25] Functional outcome of unstable pelvic ring injuries after iliosacral screw fixation: single versus two screw fixation
    Khaled, S. A.
    Soliman, O.
    Wahed, M. A.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2015, 41 (04) : 387 - 392
  • [26] Results of open reduction internal fixation versus percutaneous iliosacral screw fixation for unstable pelvic ring injuries: retrospective study of 36 patients
    Sami Abou-Khalil
    Sylvain Steinmetz
    Laurent Mustaki
    Bertrand Leger
    Eric Thein
    Olivier Borens
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 877 - 884
  • [27] Results of open reduction internal fixation versus percutaneous iliosacral screw fixation for unstable pelvic ring injuries: retrospective study of 36 patients
    Abou-Khalil, Sami
    Steinmetz, Sylvain
    Mustaki, Laurent
    Leger, Bertrand
    Thein, Eric
    Borens, Olivier
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (05): : 877 - 884
  • [28] Percutaneous iliosacral screw fixation in vertically unstable pelvic injuries, a refined conventional method
    El-Desouky, Ihab I.
    Mohamed, Molham M.
    Kandil, Ahmed E.
    ACTA ORTHOPAEDICA BELGICA, 2016, 82 (01): : 52 - 59
  • [29] Perkutane, 2D-fluoroskopisch navigierte Sakrumverschraubung in RückenlageTechnik, Möglichkeiten und GrenzenPercutaneous, 2D-fluoroscopic navigated iliosacral screw placement in the supine positionTechnique, possibilities, and limits
    D. Briem
    J. Windolf
    J.M. Rueger
    Der Unfallchirurg, 2007, 110 (5): : 393 - 401
  • [30] Isolated pelvic ring injuries: functional outcomes following percutaneous, posterior fixation
    Sullivan M.P.
    Scolaro J.A.
    Milby A.H.
    Mehta S.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (6) : 1025 - 1030