2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series

被引:93
|
作者
Gras, Florian [1 ]
Marintschev, Ivan [1 ]
Wilharm, Arne [1 ]
Klos, Kajetan [1 ]
Mueckley, Thomas [1 ]
Hofmann, Gunther O. [1 ,2 ]
机构
[1] Univ Jena, Dept Trauma Hand & Reconstruct Surg, D-6900 Jena, Germany
[2] Berufsgenossenschaftl Kliniken Halle, Halle, Germany
来源
关键词
ILIOSACRAL SCREWS; INTERNAL-FIXATION; FRACTURE-DISLOCATIONS; SACROILIAC SCREWS; SUPINE POSITION; PLACEMENT; STABILIZATION; DISRUPTIONS; FLUOROSCOPY; INSERTION;
D O I
10.1186/1471-2474-11-153
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Screw fixation of pelvic ring fractures is a common, but demanding procedure and navigation techniques were introduced to increase the precision of screw placement. The purpose of this case series was the evaluation of screw misplacement rate and functional outcome of percutaneous screw fixation of pelvic ring disruptions using a 2D navigation system. Methods: Between August 2004 and December 2007, 44 of 442 patients with pelvic injuries were included for closed reduction and percutaneous screw fixation of disrupted pelvic ring lesions using an optoelectronic 2D-fluoroscopic based navigation system. Operating and fluoroscopy time were measured, as well as peri- and postoperative complications documented. Screw position was assessed by postoperative CT scans. Quality of live was evaluated by SF 36-questionnaire in 40 of 44 patients at mean follow up 15.5 +/- 1.2 month. Results: 56 iliosacral- and 29 ramus pubic-screws were inserted ( mean operation time per screw 62 +/- 4 minutes, mean fluoroscopy time per screw 123 +/- 12 seconds). In post-operative CT-scans the screw position was assessed and graded as follows: I. secure positioning, completely in the cancellous bone (80%); II. secure positioning, but contacting cortical bone structures (14%); III. malplaced positioning, penetrating the cortical bone (6%). The malplacements predominantly occurred in bilateral overlapping screw fixation. No wound infection or iatrogenic neurovascular damage were observed. Four re-operations were performed, two of them due to implant-misplacement and two of them due to implant-failure. Conclusion: 2D-fluoroscopic navigation is a safe tool providing high accuracy of percutaneous screw placement for pelvic ring fractures, but in cases of a bilateral iliosacral screw fixation an increased risk for screw misplacement was observed. If additional ramus pubic screw fixations are performed, the retrograde inserted screws have to pass the iliopubic eminence to prevent an axial screw loosening.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] 2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series
    Florian Gras
    Ivan Marintschev
    Arne Wilharm
    Kajetan Klos
    Thomas Mückley
    Gunther O Hofmann
    BMC Musculoskeletal Disorders, 11
  • [2] Percutaneous, 2D-fluoroscopic navigated iliosacral screw placement in the supine position
    Briem, D.
    Windolf, J.
    Rueger, J. M.
    UNFALLCHIRURG, 2007, 110 (05): : 393 - 401
  • [3] 3D-Navigated percutaneous screw fixation of pelvic ring injuries - a pilot study
    Michela, Florio
    Capasso, Luigi
    Olivi, Alessandro
    Vitiello, Carla
    Leone, Antonio
    Liuzza, Francesco
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 : S28 - S33
  • [4] 2D-fluoroscopic navigated screw osteosynthesis of acetabular fractures:: A preliminary report
    Gras, F.
    Marintschev, I.
    Mendler, F.
    Wilharm, A.
    Mueckley, T.
    Hofmann, G. O.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2008, 146 (02): : 231 - 239
  • [5] Navigated Percutaneous Sacroiliac Screw Fixation in Unstable Pelvic Ring Fracture
    Azhar, Shafiq
    Syafiq, Syed
    Arif, Nik Kamarul
    Khalil, Ahmad Faiz Mohamed
    Ariffin, Mohd Hisam Muhamad
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (10)
  • [6] Computer navigated percutaneous screw fixation for traumatic pubic symphysis diastasis of unstable pelvic ring injuries
    MU Weidong WANG Hong ZHOU Dongsheng YU Lingzhi JIA Tanghong LI Lianxin Department of Orthopaedics LX Department of Dermatology Department of Anesthesiology Shandong Provincial Hospital Affihated to Shandong UniversityJinanShandong China
    中华医学杂志(英文版), 2009, (14) : 1699 - 1703
  • [7] Computer navigated percutaneous screw fixation for traumatic pubic symphysis diastasis of unstable pelvic ring injuries
    Mu Wei-dong
    Wang Hong
    Zhou Dong-sheng
    Yu Ling-zhi
    Jia Tang-hong
    Li Lian-xin
    CHINESE MEDICAL JOURNAL, 2009, 122 (14) : 1699 - 1703
  • [8] Percutaneous Ilio-sacral Screw Fixation for Unstable Pelvic Ring Injuries
    Amin, Muhammad Suhail
    Habib, Muhammad Khurram
    Khalid, Ammar
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2016, 66 (10) : S112 - S115
  • [9] Iliosacral Screw Fixation of the Unstable Pelvic Ring Injuries
    Rysavy, M.
    Pavelka, T.
    Khayarin, M.
    Dzupa, V.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2010, 77 (03) : 209 - 214
  • [10] Percutaneous Sacroiliac Screw Fixation of the Posterior Pelvic Ring
    Iorio, Justin A.
    Jakoi, Andre M.
    Rehman, Saqib
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (04) : 511 - +