摘要
Direct sampling graphite furnace atomic absorption spectrometry (DS-GF AAS) was proposed for Mg and Ca determination in desalted crude oil. A Zeeman-effect background correction system with variable magnetic field was used and measurements were carried out with low and high sensitivity. Pyrolysis and atomization temperatures, calibration with aqueous standards and the effect of sample mass to be introduced into the atomizer were evaluated. The use of chemical modifiers was not necessary for both elements. For Mg determination, two sensitivity conditions (high and low, respectively) were used: i) main absorption line (285.2 nm), 2-field mode (0.8 T) and gas stop flow during the atomization and ii) secondary absorption line (202.6 nm), 2-field mode (0.8 T) and gas stop flow during the atomization. For Ca determination, three low-sensitivity conditions using the main absorption line (422.7 nm) and variable magnetic field were used: i) 3-field dynamic mode (0.6-0.8 T) and gas stop flow during the atomization, ii) 3-field dynamic mode (0.4-0.8 T) and gas stop flow during the atomization and iii) 3-field dynamic mode (0.6-0.8 T) and gas flow during the atomization. The characteristic mass and limit of quantification for the highest sensitivity condition were 0.3 pg and 1.2 ng g(-1) for Mg and 4.8 pg and 0.1 mu g g(-1) for Ca, respectively. For all sensitivity conditions, good linearity (R-2 above 0.997) and relative standard deviation below 14% were achieved. Accuracy for DS-GF AAS method was evaluated by results comparison with those obtained by GF AAS after microwave-assisted digestion, which were in agreement. Additionally, recovery tests were carried out and recoveries for both analytes ranged from 92 to 107%. The use of DS-GF AAS provides some advantages such as simplicity, low risk of contamination and up to twelve measurements can be performed per hour.
引用
收藏
页码:1483 / 1488
页数:6
相关论文
共 50 条
  • [41] Determination of mercury in soils and sediments by graphite furnace atomic absorption spectrometry with slurry sampling
    Lopez-Garcia, I
    Sanchez-Merlos, M
    Hernandez-Cordoba, M
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (14) : 2085 - 2092
  • [42] Solid sampling graphite furnace atomic absorption spectrometry: A review
    Nomura, Cassiana Seimi
    da Silva, Cintia Soares
    Oliveira, Pedro Vitoriano
    QUIMICA NOVA, 2008, 31 (01): : 104 - 113
  • [43] Determination of lead and cadmium in Chinese crude drugs by graphite-furnace atomic absorption spectrometry
    Chuang, IC
    Huang, YL
    Lin, TH
    ANALYTICAL SCIENCES, 1999, 15 (11) : 1133 - 1136
  • [44] Determination of Lead and Cadmium in Chinese Crude Drugs by Graphite-Furnace Atomic Absorption Spectrometry
    I-Chuan Chuang
    Yeou-Lih Huang
    Te-Hsien Lin
    Analytical Sciences, 1999, 15 : 1133 - 1136
  • [45] Direct Determination of Molybdenum in Milk and Infant Food Samples Using Slurry Sampling and Graphite Furnace Atomic Absorption Spectrometry
    Flávia Regina de Amorim
    Milton Batista Franco
    Clésia Cristina Nascentes
    José Bento Borba da Silva
    Food Analytical Methods, 2011, 4 : 41 - 48
  • [46] Simultaneous Determination of Cadmium and Lead in Medicinal Plants Using Graphite Furnace Atomic Absorption Spectrometry and Direct Slurry Sampling
    Fortunato, Felipe Manfroi
    Gomes Neto, Jose Anchieta
    Giovanni Freschi, Gian Paulo
    ATOMIC SPECTROSCOPY, 2012, 33 (04) : 138 - 142
  • [47] Application of solid sampling device for direct determination of chromium and nickel in lubricating oils by graphite furnace atomic absorption spectrometry
    Polidorio, Danielle I.
    Naozuka, Juliana
    Vieira, Edivan C.
    Oliveira, Pedro V.
    ANALYTICAL LETTERS, 2008, 41 (09) : 1547 - 1554
  • [49] Direct Determination of Molybdenum in Milk and Infant Food Samples Using Slurry Sampling and Graphite Furnace Atomic Absorption Spectrometry
    de Amorim, Flavia Regina
    Franco, Milton Batista
    Nascentes, Clesia Cristina
    Borba da Silva, Jose Bento
    FOOD ANALYTICAL METHODS, 2011, 4 (01) : 41 - 48
  • [50] Determination of cadmium, copper and lead in alumina based catalysts by direct solid sampling graphite furnace atomic absorption spectrometry
    Rodrigues, Luiz Frederico
    Paz de Mattos, Julio Cezar
    Dressler, Valderi Luiz
    Pozebon, Dirce
    de Moraes Flores, Erico Marlon
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (09) : 933 - 938