Magnesium and calcium determination in desalted crude oil by direct sampling graphite furnace atomic absorption spectrometry

被引:14
|
作者
Seeger, Tassia S. [1 ]
Muller, Edson I. [1 ]
Mesko, Marcia F. [2 ]
Duarte, Fabio A. [1 ]
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
[2] Univ Fed Pelotas, Ctr Ciencias Quim Farmaceut & Alimentos, BR-96160000 Capao Do Leao, RS, Brazil
关键词
Direct sampling; Graphite furnace atomic absorption spectrometry; Magnesium; Calcium; Petroleum; MICROWAVE-INDUCED COMBUSTION; PLASMA-MASS SPECTROMETRY; ICP-MS; ELEMENT DETERMINATION; CHLORIDE SALTS; TRACE-ELEMENTS; DIGESTION; EXTRACTION; PETROLEUM; MG;
D O I
10.1016/j.fuel.2018.09.108
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Direct sampling graphite furnace atomic absorption spectrometry (DS-GF AAS) was proposed for Mg and Ca determination in desalted crude oil. A Zeeman-effect background correction system with variable magnetic field was used and measurements were carried out with low and high sensitivity. Pyrolysis and atomization temperatures, calibration with aqueous standards and the effect of sample mass to be introduced into the atomizer were evaluated. The use of chemical modifiers was not necessary for both elements. For Mg determination, two sensitivity conditions (high and low, respectively) were used: i) main absorption line (285.2 nm), 2-field mode (0.8 T) and gas stop flow during the atomization and ii) secondary absorption line (202.6 nm), 2-field mode (0.8 T) and gas stop flow during the atomization. For Ca determination, three low-sensitivity conditions using the main absorption line (422.7 nm) and variable magnetic field were used: i) 3-field dynamic mode (0.6-0.8 T) and gas stop flow during the atomization, ii) 3-field dynamic mode (0.4-0.8 T) and gas stop flow during the atomization and iii) 3-field dynamic mode (0.6-0.8 T) and gas flow during the atomization. The characteristic mass and limit of quantification for the highest sensitivity condition were 0.3 pg and 1.2 ng g(-1) for Mg and 4.8 pg and 0.1 mu g g(-1) for Ca, respectively. For all sensitivity conditions, good linearity (R-2 above 0.997) and relative standard deviation below 14% were achieved. Accuracy for DS-GF AAS method was evaluated by results comparison with those obtained by GF AAS after microwave-assisted digestion, which were in agreement. Additionally, recovery tests were carried out and recoveries for both analytes ranged from 92 to 107%. The use of DS-GF AAS provides some advantages such as simplicity, low risk of contamination and up to twelve measurements can be performed per hour.
引用
收藏
页码:1483 / 1488
页数:6
相关论文
共 50 条
  • [21] Determination of trace impurities in aluminum nitride by direct solid sampling graphite furnace atomic absorption spectrometry
    Paz de Mattos, Julio Cezar
    Rodrigues, Luiz Frederico
    de Moraes Flores, Erico Marlon
    Krivan, Viliam
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (08) : 637 - 643
  • [22] Determination of manganese and nickel in slurry sampling by graphite furnace atomic absorption spectrometry
    Pereira, Luciano Almeida
    Borges, Simone Soares de O.
    Castro, Mauricio Costa
    Borges Neto, Waldomiro
    Windmoller, Claudia Carvalhinho
    Borba da Silva, Jose Bento
    CANADIAN JOURNAL OF CHEMISTRY, 2008, 86 (04) : 312 - 316
  • [23] Determination of arsenic in edible oils by direct graphite furnace atomic absorption spectrometry
    Chen, SS
    Cheng, CC
    Chou, SS
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2003, 11 (03) : 214 - 219
  • [24] Determination of copper in edible oils by direct graphite furnace atomic absorption spectrometry
    Chen, SS
    Chen, CM
    Cheng, CC
    Chou, SS
    JOURNAL OF FOOD AND DRUG ANALYSIS, 1999, 7 (03) : 207 - 214
  • [25] Direct analysis of silica by means of solid sampling graphite furnace atomic absorption spectrometry
    Resano, M.
    Mozas, E.
    Crespo, C.
    Perez, J.
    Garcia-Ruiz, E.
    Belarra, M. A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 71-72 : 24 - 30
  • [26] Direct determination of phosphorus in biodiesel samples by graphite furnace atomic absorption spectrometry using a solid sampling accessory
    Lyra, Fernanda Henrique
    Weitzel Dias Carneiro, Maria Tereza
    Brandao, Geisamanda Pedrini
    Pessoa, Helen Moura
    Ribeiro de Castro, Eustaquio Vinicius
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (09) : 1262 - 1266
  • [28] Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of silver at trace and ultratrace levels
    Resano, M
    Aramendía, M
    García-Ruiz, E
    Crespo, C
    Belarra, MA
    ANALYTICA CHIMICA ACTA, 2006, 571 (01) : 142 - 149
  • [29] DETERMINATION OF COPPER IN BIOLOGICAL MICROSAMPLES BY DIRECT SOLID SAMPLING GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY
    EBDON, L
    EVANS, EH
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (03) : 317 - 320
  • [30] Direct determination of trace arsenic in coal by slurry-sampling graphite-furnace atomic absorption spectrometry
    Chen, Shi-Zhong
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2004, 24 (10):