Interdigitated aluminium and titanium sensors for assessing epithelial barrier functionality by electric cell-substrate impedance spectroscopy (ECIS)

被引:7
|
作者
Schmiedinger, Thomas [1 ,2 ]
Partel, Stefan [3 ]
Lechleitner, Thomas [1 ]
Eiter, Oliver [1 ]
Hekl, Daniel [1 ]
Kaseman, Stephan [3 ]
Lukas, Peter [1 ]
Edlinger, Johannes [3 ]
Lechner, Judith [4 ]
Seppi, Thomas [1 ]
机构
[1] Med Univ Innsbnick, Univ Hosp Radiotherapy & Radiat Oncol, Lab Radiobiol, Anichstr 35, A-6020 Innsbruck, Austria
[2] Univ Appl Sci Kufstein, Andreas Hofer Str 7, A-6330 Kufstein, Austria
[3] Vorarlberg Univ Appl Sci, Res Ctr Microtechnol, Hochschulstr 1, A-6850 Dornbirn, Austria
[4] Med Univ Innsbruck, Dept Physiol & Med Phys, Schopfstr 41 EG, A-6330 Innsbruck, Austria
关键词
Electric cell-substrate impedance spectroscopy; Interdigitated electrode array; Epithelial cells; Equivalent electrical circuit; SENSING ECIS; LLC-PK1; DIFFERENTIATION; OVEREXPRESSION; PERMEABILITY; SENSITIVITY; EXPRESSION; RESISTANCE; COMPLEXES; LINE;
D O I
10.1007/s10544-020-00486-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electric cell-substrate impedance spectroscopy (ECIS) enables non-invasive and continuous read-out of electrical parameters of living tissue. The aim of the current study was to investigate the performance of interdigitated sensors with 50 mu m electrode width and 50 mu m inter-electrode distance made of gold, aluminium, and titanium for monitoring the barrier properties of epithelial cells in tissue culture. At first, the measurement performance of the photolithographic fabricated sensors was characterized by defined reference electrolytes. The sensors were used to monitor the electrical properties of two adherent epithelial barrier tissue models: renal proximal tubular LLC-PK1 cells, representing a normal functional transporting epithelium, and human cervical cancer-derived HeLa cells, forming non-transporting cancerous epithelial tissue. Then, the impedance spectra obtained were analysed by numerically fitting the parameters of the two different models to the measured impedance spectrum. Aluminium sensors proved to be as sensitive and consistent in repeated online-recordings for continuous cell growth and differentiation monitoring as sensors made of gold, the standard electrode material. Titanium electrodes exhibited an elevated intrinsic ohmic resistance in comparison to gold reflecting its lower electric conductivity. Analysis of impedance spectra through applying models and numerical data fitting enabled the detailed investigation of the development and properties of a functional transporting epithelial tissue using either gold or aluminium sensors. The result of the data obtained, supports the consideration of aluminium and titanium sensor materials as potential alternatives to gold sensors for advanced application of ECIS spectroscopy.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Real-time monitoring of skin wound healing on nano-grooves topography using electric cell-substrate impedance sensing (ECIS)
    Cui, Yao
    An, Yu
    Jin, Tongyu
    Zhang, Fan
    He, Pingang
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 250 : 461 - 468
  • [42] In vitro Intestinal Epithelial Wound-healing Assays Using Electric Cell-Substrate Impedance Sensing Instrument
    Merlin-Zhang, Olivier
    Sung, Junsik
    Viennois, Emilie
    BIO-PROTOCOL, 2019, 9 (17):
  • [43] Dynamics of TGF-β induced epithelial-to-mesenchymal transition monitored by Electric Cell-Substrate Impedance Sensing
    Schneider, David
    Tarantola, Marco
    Janshoff, Andreas
    BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR CELL RESEARCH, 2011, 1813 (12): : 2099 - 2107
  • [44] Sensitivity and Validation of Porous Membrane Electrical Cell Substrate Impedance Spectroscopy (PM-ECIS) for Measuring Endothelial Barrier Properties
    Ugodnikov, Alisa
    Chebotarev, Oleg
    Persson, Henrik
    Simmons, Craig A.
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2024, 10 (08): : 5327 - 5335
  • [45] Online Measurement of Real-Time Cytotoxic Responses Induced by Multi-Component Matrices, such as Natural Products, through Electric Cell-Substrate Impedance Sensing (ECIS)
    Fallarero, Adyary
    Batista-Gonzalez, Ana E.
    Hiltunen, Anna K.
    Liimatainen, Jaana
    Karonen, Maarit
    Vuorela, Pia M.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2015, 16 (11): : 27044 - 27057
  • [46] Electric cell-substrate impedance sensing (ECIS) based real-time measurement of titer dependent cytotoxicity induced by adenoviral vectors in an IPI-2I cell culture model
    Mueller, Jakob
    Thirion, Christian
    Pfaffl, Michael W.
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05): : 2000 - 2005
  • [47] DEVELOPMENT OF A THREE-DIMENSIONAL (3D) ALL-HUMAN, IN VITRO MODEL OF THE BLOOD-BRAIN BARRIER FOR CANCER METASTASIS STUDIES USING ELECTRIC CELL-SUBSTRATE IMPEDANCE SENSING SYSTEM (ECIS) AND TRANSWELLS
    Fry, K. E.
    Pilkington, G. J.
    ANTICANCER RESEARCH, 2008, 28 (5C) : 3285 - 3285
  • [48] Using Electric Cell-substrate Impedance Sensing (ECIS) Technology as a Tool for Mathematical Analysis of the Effects of Glucose on Bone-like Osteosarcoma Cells (UMR 106-01 BSP)
    Choi, Jeannie
    Hernandez, Bryan
    Joseph, Eugene
    FASEB JOURNAL, 2018, 32 (01):
  • [49] Real-Time Measurement of Melanoma Cell-Mediated Human Brain Endothelial Barrier Disruption Using Electric Cell-Substrate Impedance Sensing Technology
    Anchan, Akshata
    Kalogirou-Baldwin, Panagiota
    Johnson, Rebecca
    Kho, Dan T.
    Joseph, Wayne
    Hucklesby, James
    Finlay, Graeme J.
    O'Carroll, Simon J.
    Angel, Catherine E.
    Graham, E. Scott
    BIOSENSORS-BASEL, 2019, 9 (02):
  • [50] Effect of exopolysaccharide from Ganoderma applanatum on the electrical properties of mouse fibroblast cells line L929 culture using an electric cell-substrate impedance sensing (ECIS) - Preliminary study
    Prendecka, Monika
    Mlak, Radoslaw
    Jaszek, Magdalena
    Osinska-Jaroszuk, Monika
    Jakubiak-Hulicz, Monika
    Leibold, Christian
    Bieser, Armin
    Wojcik, Waldemar
    Malecka-Massalska, Teresa
    ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2016, 23 (02) : 280 - 284