Interdigitated aluminium and titanium sensors for assessing epithelial barrier functionality by electric cell-substrate impedance spectroscopy (ECIS)

被引:7
|
作者
Schmiedinger, Thomas [1 ,2 ]
Partel, Stefan [3 ]
Lechleitner, Thomas [1 ]
Eiter, Oliver [1 ]
Hekl, Daniel [1 ]
Kaseman, Stephan [3 ]
Lukas, Peter [1 ]
Edlinger, Johannes [3 ]
Lechner, Judith [4 ]
Seppi, Thomas [1 ]
机构
[1] Med Univ Innsbnick, Univ Hosp Radiotherapy & Radiat Oncol, Lab Radiobiol, Anichstr 35, A-6020 Innsbruck, Austria
[2] Univ Appl Sci Kufstein, Andreas Hofer Str 7, A-6330 Kufstein, Austria
[3] Vorarlberg Univ Appl Sci, Res Ctr Microtechnol, Hochschulstr 1, A-6850 Dornbirn, Austria
[4] Med Univ Innsbruck, Dept Physiol & Med Phys, Schopfstr 41 EG, A-6330 Innsbruck, Austria
关键词
Electric cell-substrate impedance spectroscopy; Interdigitated electrode array; Epithelial cells; Equivalent electrical circuit; SENSING ECIS; LLC-PK1; DIFFERENTIATION; OVEREXPRESSION; PERMEABILITY; SENSITIVITY; EXPRESSION; RESISTANCE; COMPLEXES; LINE;
D O I
10.1007/s10544-020-00486-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electric cell-substrate impedance spectroscopy (ECIS) enables non-invasive and continuous read-out of electrical parameters of living tissue. The aim of the current study was to investigate the performance of interdigitated sensors with 50 mu m electrode width and 50 mu m inter-electrode distance made of gold, aluminium, and titanium for monitoring the barrier properties of epithelial cells in tissue culture. At first, the measurement performance of the photolithographic fabricated sensors was characterized by defined reference electrolytes. The sensors were used to monitor the electrical properties of two adherent epithelial barrier tissue models: renal proximal tubular LLC-PK1 cells, representing a normal functional transporting epithelium, and human cervical cancer-derived HeLa cells, forming non-transporting cancerous epithelial tissue. Then, the impedance spectra obtained were analysed by numerically fitting the parameters of the two different models to the measured impedance spectrum. Aluminium sensors proved to be as sensitive and consistent in repeated online-recordings for continuous cell growth and differentiation monitoring as sensors made of gold, the standard electrode material. Titanium electrodes exhibited an elevated intrinsic ohmic resistance in comparison to gold reflecting its lower electric conductivity. Analysis of impedance spectra through applying models and numerical data fitting enabled the detailed investigation of the development and properties of a functional transporting epithelial tissue using either gold or aluminium sensors. The result of the data obtained, supports the consideration of aluminium and titanium sensor materials as potential alternatives to gold sensors for advanced application of ECIS spectroscopy.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Electric cell-substrate impedance sensing (ECIS) as a noninvasive means to monitor the kinetics of cell spreading to artificial surfaces
    Wegener, J
    Keese, CR
    Giaever, I
    EXPERIMENTAL CELL RESEARCH, 2000, 259 (01) : 158 - 166
  • [22] Development of Interdigitated and Chain-Shaped Electrode Array for Electric Cell-Substrate Impedance Sensing
    Park, Jinsoo
    Cho, Sungbo
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2016, 16 (11) : 11911 - 11915
  • [23] Rapid assay of stem cell functionality and potency using electric cell-substrate impedance sensing
    Michael J. Rutten
    Bryan Laraway
    Cynthia R. Gregory
    Hua Xie
    Christian Renken
    Charles Keese
    Kenton W. Gregory
    Stem Cell Research & Therapy, 6
  • [24] Comparison of Fish and Mammalian Cell Line Responses to Multiple Chemicals Using Electric Cell-Substrate Impedance Sensing (ECIS)
    Brennan, Linda
    Widder, Mark
    van der Schalie, William
    IN VITRO CELLULAR & DEVELOPMENTAL BIOLOGY-ANIMAL, 2010, 46 : S101 - S101
  • [25] Rapid assay of stem cell functionality and potency using electric cell-substrate impedance sensing
    Rutten, Michael J.
    Laraway, Bryan
    Gregory, Cynthia R.
    Xie, Hua
    Renken, Christian
    Keese, Charles
    Gregory, Kenton W.
    STEM CELL RESEARCH & THERAPY, 2015, 6
  • [26] The influence of the electrode dimension on the detection sensitivity of electric cell-substrate impedance sensing (ECIS) and its mathematical modeling
    Zhang, Xudong
    Wang, William
    Nordin, Anis Nurashikin
    Li, Fang
    Jang, Sunghoon
    Voiculescu, Ioana
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 : 780 - 790
  • [27] A quantitative cell modeling and wound-healing analysis based on the Electric Cell-substrate Impedance Sensing (ECIS) method
    Yang, Jen Ming
    Chen, Szi-Wen
    Yang, Jhe-Hao
    Hsu, Chih-Chin
    Wang, Jong-Shyan
    COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 69 : 134 - 143
  • [28] Dissecting the extravasation process of metastatic breast cancer cells using an Electric Cell-Substrate Impedance Sensing (ECIS) assay
    Price, Janet E.
    Newsham, Irene F.
    CLINICAL & EXPERIMENTAL METASTASIS, 2007, 24 (04) : 276 - 277
  • [29] The Effect of ABO Immune Complexes on Endothelial Cell Integrity As Measured By Electric Cell-Substrate Impedance Sensing (ECIS) and Confocal Microscopy
    McRae, Hannah L.
    Slavin, Spencer
    Rahman, Arshad
    Blumberg, Neil
    Refaai, Majed A.
    BLOOD, 2017, 130
  • [30] Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility
    Szulcek, Robert
    Bogaard, Harm Jan
    Amerongen, Geerten P. van Nieuw
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2014, (85):