A Simple Method for In Vivo Measurement of Implant Rod Three-Dimensional Geometry During Scoliosis Surgery

被引:4
|
作者
Salmingo, Remel A. [2 ]
Tadano, Shigeru [1 ]
Fujisaki, Kazuhiro [1 ]
Abe, Yuichiro [3 ]
Ito, Manabu [4 ]
机构
[1] Hokkaido Univ, Fac Engn, Div Human Mech Syst & Design, Kita Ku, Sapporo, Hokkaido 0608628, Japan
[2] Hokkaido Univ, Grad Sch Engn, Div Human Mech Syst & Design, Kita Ku, Sapporo, Hokkaido 0608628, Japan
[3] Eniwa Hosp, Dept Orthopaed Surg, Eniwa 0611449, Japan
[4] Hokkaido Univ, Grad Sch Med, Dept Orthopaed Surg, Kita Ku, Sapporo, Hokkaido 0608638, Japan
关键词
Scoliosis; implant fixation; three-dimensional rod geometry; projective geometry; biomechanics; bone; INSTRUMENTATION;
D O I
10.1115/1.4006687
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Scoliosis is defined as a spinal pathology characterized as a three-dimensional deformity of the spine combined with vertebral rotation. Treatment for severe scoliosis is achieved when the scoliotic spine is surgically corrected and fixed using implanted rods and screws. Several studies performed biomechanical modeling and corrective forces measurements of scoliosis correction. These studies were able to predict the clinical outcome and measured the corrective forces acting on screws, however, they were not able to measure the intraoperative three-dimensional geometry of the spinal rod. In effect, the results of biomechanical modeling might not be so realistic and the corrective forces during the surgical correction procedure were intra-operatively difficult to measure. Projective geometry has been shown to be successful in the reconstruction of a three-dimensional structure using a series of images obtained from different views. In this study, we propose a new method to measure the three-dimensional geometry of an implant rod using two cameras. The reconstruction method requires only a few parameters, the included angle theta between the two cameras, the actual length of the rod in mm, and the location of points for curve fitting. The implant rod utilized in spine surgery was used to evaluate the accuracy of the current method. The three-dimensional geometry of the rod was measured from the image obtained by a scanner and compared to the proposed method using two cameras. The mean error in the reconstruction measurements ranged from 0.32 to 0.45 mm. The method presented here demonstrated the possibility of intra-operatively measuring the three-dimensional geometry of spinal rod. The proposed method could be used in surgical procedures to better understand the biomechanics of scoliosis correction through real-time measurement of three-dimensional implant rod geometry in vivo. [DOI: 10.1115/1.4006687]
引用
收藏
页数:5
相关论文
共 50 条
  • [21] A simple three-dimensional stent for proper placement of mini-implant
    Sumathi Felicita A.
    Progress in Orthodontics, 14 (1)
  • [22] Intraoperative Three-Dimensional Correction During Rod Rotation Technique
    Lafon, Yoann
    Lafage, Virginie
    Dubousset, Jean
    Skalli, Wafa
    SPINE, 2009, 34 (05) : 512 - 519
  • [23] Three-Dimensional Plotting and Printing of an Implant Drilling Guide: Simplifying Guided Implant Surgery
    Fluegge, Tabea Viktoria
    Nelson, Katja
    Schmelzeisen, Rainer
    Metzger, Marc Christian
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (08) : 1340 - 1346
  • [24] Three-dimensional finite element stress analysis of a cuneiform-geometry implant
    Cruz, M
    Wassall, T
    Toledo, EM
    Barra, LPD
    Lemonge, ACD
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (05) : 675 - 684
  • [25] Three-dimensional treatment for scoliosis. A physiotherapeutic method for deformities of the spine
    Bjorke, Gerd
    EUROPEAN JOURNAL OF PHYSIOTHERAPY, 2010, 12 (03) : 175 - 175
  • [26] The use of a photogrammetric method for the three-dimensional evaluation of spinal correction in scoliosis
    Eric Berthonnaud
    Patrice Papin
    Julie Deceuninck
    Radwan Hilmi
    Jean Claude Bernard
    Joannes Dimnet
    International Orthopaedics, 2016, 40 : 1187 - 1196
  • [27] The use of a photogrammetric method for the three-dimensional evaluation of spinal correction in scoliosis
    Berthonnaud, Eric
    Papin, Patrice
    Deceuninck, Julie
    Hilmi, Radwan
    Bernard, Jean Claude
    Dimnet, Joannes
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (06) : 1187 - 1196
  • [28] Three-dimensional in vivo measurement of lumbar spine segmental motion
    Ochia, Ruth S.
    Inoue, Nozomu
    Renner, Susan M.
    Lorenz, Eric P.
    Lim, Tae-Hong
    Andersson, Gunnar B. J.
    An, Howard S.
    SPINE, 2006, 31 (18) : 2073 - 2078
  • [29] Development of Axially Simplified Method of Characteristics Three-Dimensional Geometry
    Giho, Akinori
    Sakai, Koji
    Imamura, Yasuhiro
    Sakuragi, Hirotaka
    Miyawak, Koslike
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, 45 (10) : 985 - 996
  • [30] Geometry-related treatments for three-dimensional meshless method
    Lee, Ming-Hsiao
    Chen, Wen-Hwa
    CMES - Computer Modeling in Engineering and Sciences, 2010, 61 (03): : 249 - 271