A Simple Method for In Vivo Measurement of Implant Rod Three-Dimensional Geometry During Scoliosis Surgery

被引:4
|
作者
Salmingo, Remel A. [2 ]
Tadano, Shigeru [1 ]
Fujisaki, Kazuhiro [1 ]
Abe, Yuichiro [3 ]
Ito, Manabu [4 ]
机构
[1] Hokkaido Univ, Fac Engn, Div Human Mech Syst & Design, Kita Ku, Sapporo, Hokkaido 0608628, Japan
[2] Hokkaido Univ, Grad Sch Engn, Div Human Mech Syst & Design, Kita Ku, Sapporo, Hokkaido 0608628, Japan
[3] Eniwa Hosp, Dept Orthopaed Surg, Eniwa 0611449, Japan
[4] Hokkaido Univ, Grad Sch Med, Dept Orthopaed Surg, Kita Ku, Sapporo, Hokkaido 0608638, Japan
关键词
Scoliosis; implant fixation; three-dimensional rod geometry; projective geometry; biomechanics; bone; INSTRUMENTATION;
D O I
10.1115/1.4006687
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Scoliosis is defined as a spinal pathology characterized as a three-dimensional deformity of the spine combined with vertebral rotation. Treatment for severe scoliosis is achieved when the scoliotic spine is surgically corrected and fixed using implanted rods and screws. Several studies performed biomechanical modeling and corrective forces measurements of scoliosis correction. These studies were able to predict the clinical outcome and measured the corrective forces acting on screws, however, they were not able to measure the intraoperative three-dimensional geometry of the spinal rod. In effect, the results of biomechanical modeling might not be so realistic and the corrective forces during the surgical correction procedure were intra-operatively difficult to measure. Projective geometry has been shown to be successful in the reconstruction of a three-dimensional structure using a series of images obtained from different views. In this study, we propose a new method to measure the three-dimensional geometry of an implant rod using two cameras. The reconstruction method requires only a few parameters, the included angle theta between the two cameras, the actual length of the rod in mm, and the location of points for curve fitting. The implant rod utilized in spine surgery was used to evaluate the accuracy of the current method. The three-dimensional geometry of the rod was measured from the image obtained by a scanner and compared to the proposed method using two cameras. The mean error in the reconstruction measurements ranged from 0.32 to 0.45 mm. The method presented here demonstrated the possibility of intra-operatively measuring the three-dimensional geometry of spinal rod. The proposed method could be used in surgical procedures to better understand the biomechanics of scoliosis correction through real-time measurement of three-dimensional implant rod geometry in vivo. [DOI: 10.1115/1.4006687]
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Intraoperative implant rod three-dimensional geometry measured by dual camera system during scoliosis surgery
    Salmingo, Remel Alingalan
    Tadano, Shigeru
    Abe, Yuichiro
    Ito, Manabu
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2016, 27 (01) : 49 - 62
  • [2] The method for measurement of the three-dimensional scoliosis angle from standard radiographs
    Paweł Główka
    Wojciech Politarczyk
    Piotr Janusz
    Łukasz Woźniak
    Tomasz Kotwicki
    BMC Musculoskeletal Disorders, 21
  • [3] The method for measurement of the three-dimensional scoliosis angle from standard radiographs
    Glowka, Pawel
    Politarczyk, Wojciech
    Janusz, Piotr
    Wozniak, Lukasz
    Kotwicki, Tomasz
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [4] A simple and quantitative method for three-dimensional measurement of normal smiles
    Kang, YS
    Bae, YC
    Hwang, SM
    Nam, SB
    ANNALS OF PLASTIC SURGERY, 2005, 54 (04) : 379 - 383
  • [5] The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template
    Matta, Ragai-Edward
    Bergauer, Bastian
    Adler, Werner
    Wichmann, Manfred
    Nickenig, Hans-Joachim
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (06) : 804 - 808
  • [6] In vivo three-dimensional segmental analysis of adolescent idiopathic scoliosis
    Hattori, Takako
    Sakaura, Hironobu
    Iwasaki, Motoki
    Nagamoto, Yukitaka
    Yoshikawa, Hideki
    Sugamoto, Kazuomi
    EUROPEAN SPINE JOURNAL, 2011, 20 (10) : 1745 - 1750
  • [7] In vivo three-dimensional segmental analysis of adolescent idiopathic scoliosis
    Takako Hattori
    Hironobu Sakaura
    Motoki Iwasaki
    Yukitaka Nagamoto
    Hideki Yoshikawa
    Kazuomi Sugamoto
    European Spine Journal, 2011, 20 : 1745 - 1750
  • [8] Three-dimensional measurement of machine tool insert geometry
    Bieman, Leonard H.
    Sensors (Peterborough, NH), 1994, 11 (12): : 26 - 28
  • [9] A method for the measurement of three-dimensional geometry of casts used for the manufacture of ankle foot orthoses
    Sykes, N
    Peacock, JC
    Johnson, GR
    CLINICAL BIOMECHANICS, 1998, 13 (07) : 542 - 547
  • [10] Three-dimensional deep learning to automatically generate cranial implant geometry
    Chieh-Tsai Wu
    Yao-Hung Yang
    Yau-Zen Chang
    Scientific Reports, 12