Determination of Small MLC-Fields Corrections Factors for Several Detectors Using Monte-Carlo Simulations and EBT3 Gafchromic Films

被引:0
|
作者
Younes, T. [1 ,2 ,3 ]
Simon, L. [1 ,2 ]
Chauvin, M. [1 ]
Fares, G. [3 ]
Vieillevigne, L. [1 ,2 ]
机构
[1] Univ Toulouse 3, ERL5294, CNRS, Canc Res Ctr Toulouse,UMR1037,INSERM,Oncopole Tou, 2 Ave Hubert Curien, F-31037 Toulouse 1, France
[2] Canc Univ Inst Toulouse, 1 Ave Irene Joliot Curie, F-31059 Toulouse 9, France
[3] Univ St Joseph Beyrouth, Fac Sci, Campus Sci & Technol, Mar Roukos Dekwaneh, Lebanon
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-F-108-0
引用
收藏
页数:1
相关论文
共 23 条
  • [1] Monte Carlo calculated output correction factors for Gafchromic EBT3 film for relative dosimetry in small stereotactic radiosurgery fields
    Johnny E. Morales
    Martin Butson
    Robin Hill
    Scott B. Crowe
    J. V. Trapp
    Physical and Engineering Sciences in Medicine, 2020, 43 : 609 - 616
  • [2] Monte Carlo calculated output correction factors for Gafchromic EBT3 film for relative dosimetry in small stereotactic radiosurgery fields
    Morales, Johnny E.
    Butson, Martin
    Hill, Robin
    Crowe, Scott B.
    Trapp, J., V
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (02) : 609 - 616
  • [3] Use of EBT3 Gafchromic films for Monte Carlo validation of CyberknifeTM treatment plan
    Coutand, P.
    Badel, J. N.
    Lafay, F.
    Malet, C.
    Zahra-Ayadi, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S170 - S170
  • [4] On the use of Gafchromic EBT3 films for validating a commercial electron Monte Carlo dose calculation algorithm
    Chan, EuJin
    Lydon, Jenny
    Kron, Tomas
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (05): : 2091 - 2102
  • [5] Monte-Carlo calculation of output correction factors for ionization chambers, solid-state detectors, and EBT3 film in small fields of high-energy photons
    Klimanov, Vladimir A.
    Kirpichev, Yury S.
    Serikbekova, Zarina K.
    Belousov, Alexandr, V
    Krusanov, Grigorii A.
    Walwyn-Salas, Gonzalo
    Morozov, Vladimir N.
    Kolyvanova, Maria A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (01):
  • [6] Commissioning and Validation of EBT3 Gafchromic Films for Measurements of Dose Profiles and Integrals of Dose in Small Fields
    Dufreneix, S.
    Bordy, J.
    Delaunay, F.
    Daures, J.
    Gouriou, J.
    Le Roy, M.
    Ostrowsky, A.
    Rapp, B.
    Sommier, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 547 - 548
  • [7] A Study of Surface Dosimetry for Whole Breast Irradiation Geometry Using EBT3 Gafchromic Film and Monte Carlo Simulation
    Su, S.
    Carpentier, E.
    Duzenli, C.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [8] Monte Carlo simulations for validation of an EBT3 Gafchromic film dosimetry technique for measurement of surface dose in the presence of breast support devices
    Su, Shiqin
    Carpentier, Emilie
    Duzenli, Cheryl
    MEDICAL PHYSICS, 2021, 48 (08) : 4707 - 4708
  • [9] Validation of fast Monte Carlo dose calculation in small animal radiotherapy with EBT3 radiochromic films
    Noblet, C.
    Chiavassa, S.
    Smekens, F.
    Sarrut, D.
    Passal, V.
    Suhard, J.
    Lisbona, A.
    Paris, F.
    Delpon, G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (09): : 3521 - +
  • [10] Can Gafchromic EBT3 films effectively characterize small fields of 6 MV unflattened photon beams of Cyberknife system?
    Amalraj, Jerrin
    Velayudham, Ramasubramanian
    Anchineyan, Pichandi
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2018, 24 (04): : 181 - 187