Reconstruction of the Superior Glenoid Labrum With Biceps Tendon Autograft: A Cadaveric Biomechanical Study

被引:7
|
作者
Chen, Raymond E. [1 ]
Soin, Sandeep P. [1 ]
El-Shaar, Rami [1 ]
Awad, Hani A. [1 ]
Maloney, Michael D. [1 ]
Voloshin, Ilya [1 ]
机构
[1] Univ Rochester, Dept Orthopaed Surg & Rehabil, Rochester, NY USA
关键词
ROTATOR CUFF TEARS; LONG HEAD; NONOPERATIVE MANAGEMENT; CONCAVITY-COMPRESSION; STABILITY; ANTERIOR; LESIONS; REPAIR; JOINT;
D O I
10.1016/j.arthro.2018.08.049
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To describe 2 superior labral reconstruction techniques using long head of the biceps (LHB) autograft and to investigate the ability of the 2 reconstruction techniques to restore superior restraint to the glenohumeral joint compared with superior labrum-deficient models. Methods: In this biomechanical study, 10 cadaveric shoulders were cycled on a servohydraulic machine while the force required to cause superior subluxation was recorded. Each specimen was cycled under 4 conditions: intact labrum, SLAP tear, posterior (9- to 12-o'clock position) labral reconstruction using LHB autograft (superior labral reconstruction 1 [SLR1]), and 180 degrees (9- to 3-o'clock position) labral reconstruction using LHB autograft (superior labral reconstruction 2 [SLR2]). Results: The mean peak force required to cause superior subluxation in the intact labrum was 32.75 N versus 19.75 N in the SLAP tear (P = .0120). SLR1 required a mean peak force of 31.23 N versus 44.09 N for SLR2 (P = .0175). SLR1 required 94.96% of the force needed in the intact labrum to cause subluxation, whereas SLR2 required 140.6%. SLR1 and SLR2 required 34.21% higher (P = .0074) and 79.84% higher (P = .0033) forces, respectively, to generate subluxation compared with the SLAP tear state. Conclusions: Both proposed superior labral reconstruction techniques increased the force needed for humeral head superior migration in the setting of a labral tear. SLR1 (posterior labral reconstruction) closely matched the constraint of an intact labrum, whereas SLR2 (180 degrees labral reconstruction) provided greater superior constraint than an intact labrum. Clinical Relevance: The natural history of irreparable rotator cuff tears results in superior glenohumeral escape and eventual arthrosis. The superior glenoid labrum is an important contributor to superior glenohumeral constraint and is often degenerated in this setting. Clinical application of the 2 described superior labral reconstruction techniques may improve glenohumeral superior stability in patients with rotator cuff disease and superior labral deficiency.
引用
收藏
页码:353 / 358
页数:6
相关论文
共 50 条
  • [31] Dynamic Ultrasonography of the Intra-Articular Long Head Biceps Tendon and Superior Labrum
    Hsiao, Ming-Yen
    Hung, Chen-Yu
    Chang, Ke-Vin
    Ozcakar, Levent
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2016, 95 (11) : E183 - E184
  • [32] Origin of the Tendon of the Long Head of the Biceps Brachii Muscle and its Relationship with Glenoid Labrum in Human Foetuses
    Reis, Francisco Prado
    Aragao, Jose Aderval
    Moura, Gustavo Souza
    de Santana, Iuri Amorim
    Nunes Carvalho, Eric Allan
    Correa Feitosa, Vera Lucia
    Prado Nunes, Marco Antonio
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2009, 27 (01): : 169 - 172
  • [33] Improved Clinical and Radiologic Outcomes Seen after Superior Capsule Reconstruction using Long Head Biceps Tendon Autograft
    Kim, Doosup
    Um, Jaewoong
    Lee, Junhyeok
    Kim, Jaehyeon
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2021, 37 (09): : 2756 - 2767
  • [34] Late reconstruction of chronic distal biceps tendon ruptures with a semitendinosus autograft technique
    Wiley, William B.
    Noble, Jeffrey S.
    Dulaney, Thomas D.
    Bell, Robert H.
    Noble, Daniel D.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (04) : 440 - 444
  • [35] Rotator Cuff Anterior Cable Reconstruction With Long Head of Biceps Tendon Autograft
    Chen, Raymond E.
    Bakhsh, Wajeeh R.
    Lipof, Jason S.
    McVicker, Zachary G.
    Voloshin, Ilya
    ARTHROSCOPY TECHNIQUES, 2020, 9 (06): : E711 - E715
  • [36] Superior Capsular Reconstruction using the Long Head of the Biceps Tendon: The Biceps Loop Technique
    Brandao, Bruno Lobo
    da Fonseca, Raphael Soares
    Zaluski, Alexandre Dreifus
    Carneiro, Bernardo Gribel
    Cohen, Marcio Theo
    Motta Filho, Geraldo da Rocha
    ARTHROSCOPY TECHNIQUES, 2021, 10 (06): : E1647 - E1653
  • [37] Quantitative and Computed Tomography Anatomic Analysis of Glenoid Fixation for Superior Capsule Reconstruction: A Cadaveric Study
    Schon, Jason M.
    Katthagen, J. Christoph
    Dupre, Cameron N.
    Mitchell, Justin J.
    Turnbull, Travis Lee
    Adams, Christopher R.
    Denard, Patrick J.
    Millett, Peter J.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (06): : 1131 - 1137
  • [38] Biomechanical evaluation of using one hamstrings tendon for ACL reconstruction: a human cadaveric study
    Zamarra, Giovanni
    Fisher, Matthew B.
    Woo, Savio L-Y.
    Cerulli, Giuliano
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (01) : 11 - 19
  • [39] Biomechanical evaluation of using one hamstrings tendon for ACL reconstruction: a human cadaveric study
    Giovanni Zamarra
    Matthew B. Fisher
    Savio L-Y. Woo
    Giuliano Cerulli
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 11 - 19
  • [40] Arthroscopic Superior Capsule Reconstruction with a Long Head of the Biceps Tendon Autograft: One-Year Follow-up Results
    Kalina, R.
    Neoral, P.
    Sigmund, M.
    Gallo, J.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2023, 90 (06) : 391 - 399