Reconstruction of the Superior Glenoid Labrum With Biceps Tendon Autograft: A Cadaveric Biomechanical Study

被引:7
|
作者
Chen, Raymond E. [1 ]
Soin, Sandeep P. [1 ]
El-Shaar, Rami [1 ]
Awad, Hani A. [1 ]
Maloney, Michael D. [1 ]
Voloshin, Ilya [1 ]
机构
[1] Univ Rochester, Dept Orthopaed Surg & Rehabil, Rochester, NY USA
关键词
ROTATOR CUFF TEARS; LONG HEAD; NONOPERATIVE MANAGEMENT; CONCAVITY-COMPRESSION; STABILITY; ANTERIOR; LESIONS; REPAIR; JOINT;
D O I
10.1016/j.arthro.2018.08.049
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To describe 2 superior labral reconstruction techniques using long head of the biceps (LHB) autograft and to investigate the ability of the 2 reconstruction techniques to restore superior restraint to the glenohumeral joint compared with superior labrum-deficient models. Methods: In this biomechanical study, 10 cadaveric shoulders were cycled on a servohydraulic machine while the force required to cause superior subluxation was recorded. Each specimen was cycled under 4 conditions: intact labrum, SLAP tear, posterior (9- to 12-o'clock position) labral reconstruction using LHB autograft (superior labral reconstruction 1 [SLR1]), and 180 degrees (9- to 3-o'clock position) labral reconstruction using LHB autograft (superior labral reconstruction 2 [SLR2]). Results: The mean peak force required to cause superior subluxation in the intact labrum was 32.75 N versus 19.75 N in the SLAP tear (P = .0120). SLR1 required a mean peak force of 31.23 N versus 44.09 N for SLR2 (P = .0175). SLR1 required 94.96% of the force needed in the intact labrum to cause subluxation, whereas SLR2 required 140.6%. SLR1 and SLR2 required 34.21% higher (P = .0074) and 79.84% higher (P = .0033) forces, respectively, to generate subluxation compared with the SLAP tear state. Conclusions: Both proposed superior labral reconstruction techniques increased the force needed for humeral head superior migration in the setting of a labral tear. SLR1 (posterior labral reconstruction) closely matched the constraint of an intact labrum, whereas SLR2 (180 degrees labral reconstruction) provided greater superior constraint than an intact labrum. Clinical Relevance: The natural history of irreparable rotator cuff tears results in superior glenohumeral escape and eventual arthrosis. The superior glenoid labrum is an important contributor to superior glenohumeral constraint and is often degenerated in this setting. Clinical application of the 2 described superior labral reconstruction techniques may improve glenohumeral superior stability in patients with rotator cuff disease and superior labral deficiency.
引用
收藏
页码:353 / 358
页数:6
相关论文
共 50 条
  • [21] Quantitative analysis of attachment of the labrum to the glenoid fossa: a cadaveric study
    Yoshida, Masahito
    Goto, Hideyuki
    Nozaki, Masahiro
    Nishimori, Yasuhiro
    Takenaga, Tetsuya
    Murase, Atsunori
    Nagaya, Yuko
    Iguchi, Hirotaka
    Kobayashi, Masaaki
    Sugimoto, Katsumasa
    Nishiyama, Takeshi
    Otsuka, Takanobu
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2015, 20 (05) : 823 - 829
  • [22] Molecular Pattern and Density of Axons in the Long Head of the Biceps Tendon and the Superior Labrum
    Boesmueller, Sandra
    Blumer, Roland
    Gesslbauer, Bernhard
    Hirtler, Lena
    Fialka, Christian
    Mittermayr, Rainer
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (12)
  • [23] The superior labrum biceps tendon complex. Bringing more light into the darkness
    Imhoff, AB
    Burkart, A
    ORTHOPADE, 2003, 32 (07): : 571 - 571
  • [24] The high frequency of superior labrum, biceps tendon, and superior rotator cuff pathologies in patients with subscapularis tears: A cohort study
    Ataoglu, Muhammet Baybars
    Cetinkaya, Mehmet
    Ozer, Mustafa
    Ayanoglu, Tacettin
    Kanatli, Ulunay
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (02) : 304 - 309
  • [25] Biceps Smash Technique: Biceps Tendon Autograft Augmentation for Arthroscopic Rotator Cuff Reconstruction
    Endell, David
    Ruettershoff, Katja
    Scheibel, Markus
    ARTHROSCOPY TECHNIQUES, 2023, 12 (03): : E383 - E386
  • [26] Distal biceps tendon anatomy: A cadaveric study
    Eames, M. H. A.
    Bain, G. I.
    Fogg, Q. A.
    van Riet, R. P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (05): : 1044 - 1049
  • [27] Arthroscopic Superior Capsular Reconstruction With Biceps Autograft: Snake Technique
    Kim, Doosup
    Jang, Younghwan
    Park, Jisu
    On, Myounggi
    ARTHROSCOPY TECHNIQUES, 2019, 8 (10): : E1085 - E1092
  • [28] Comparative analysis of superior capsule reconstruction between long head of biceps tendon autograft and human dermis allograft
    Kim, Doo Sup
    Han, Jin Young
    Park, Yeon Jae
    Kwak, Ji Woong
    Lee, Bum Seok
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (04) : 820 - 831
  • [29] Anatomic Analysis of the Attachment of the Posteroinferior Labrum and Capsule to the Glenoid: A Cadaveric Study
    Koga, Akihisa
    Itoigawa, Yoshiaki
    Wada, Tomoki
    Morikawa, Daichi
    Ichimura, Koichiro
    Sakai, Tatsuo
    Kawasaki, Takayuki
    Maruyama, Yuichiro
    Kaneko, Kazuo
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2020, 36 (11): : 2814 - 2819
  • [30] Patellar tendon reconstruction augmented by a free autograft of the biceps tendon attached to the fibular head
    Peyser, AB
    Makley, JT
    ORTHOPEDICS, 1996, 19 (06) : 545 - 549