Effect of spatial coherence on application of in-line phase contrast imaging to synchrotron radiation mammography

被引:26
|
作者
Xiao, TQ [1 ]
Bergamaschi, A
Dreossi, D
Longo, R
Olivo, A
Pani, S
Rigon, L
Rokvic, T
Venanzi, C
Castelli, E
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai Synchrotron Radiat Facil, Shanghai 201800, Peoples R China
[2] Univ Trieste, Dipartimento Fis, Trieste, Italy
[3] Ist Nazl Fis Nucl, Sez Trieste, Trieste, Italy
[4] Univ Belgrade, Fac Phys, Belgrade 11001, Serbia Monteneg
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2005年 / 548卷 / 1-2期
关键词
spatial coherence; phase contrast imaging; mammography; synchrotron radiation;
D O I
10.1016/j.nima.2005.03.083
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Effect of spatial coherence on the application of in-line phase contrast imaging (IL-PCI) to synchrotron radiation (SR) mammography is investigated experimentally at SYRMEP/ELETTRA. Factors that are related to spatial coherence and IL-PCI image quality, which include vertical and horizontal beam, photon energy, slit width, sample-detector distance and detector resolution, are analyzed. The experimental results demonstrate that better IL-PCI image quality could be achieved in the vertical beam. As for the slit width, the spatial coherence for horizontal beam remains almost the same until the slit width is gradually closed to 5 mm. For mammography applications of ILPCI, slit width of 100mm could be employed and high-enough image quality can still be obtained. Lower photon energy results in better coherence and correspondingly better IL-PCI image quality. By compromising the dose and image quality, photon energy of similar to 19 keV is recommended for SR mammography. To preserve the edge enhancement resulting from good coherence of SR, an appropriate sample-detector distance and a practical detector should be selected. The optimum sample-detector distance highly depends on detector resolution. For high-resolution film, the best IL-PCI imaging quality is obtained at a closer sample-detector distance. For an X-ray CCD with pixel size of 14 mu m, about 1.5m is needed to achieve optimum image quality. The large pixel size of the detector will deteriorate the edge-enhancing efficiency and results in lower IL-PCI imaging quality. In practice, the spatial resolution and sensitivity of the detectors should be compromised. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:155 / 162
页数:8
相关论文
共 50 条
  • [31] In-line phase contrast imaging for particle analysis in complex liquid media
    Owen, R
    Marks, C
    Canty, T
    PROCEEDINGS OF THE 46TH ANNUAL ISA ANALYSIS DIVISION SYMPOSIUM, VOL 34, 2001, 410 : 81 - 85
  • [32] Evaluation of edge effect due to phase contrast imaging for mammography
    Matsuo, S
    Katafuchi, T
    Tohyama, K
    Morishita, J
    Yamada, K
    Fujita, H
    MEDICAL PHYSICS, 2005, 32 (08) : 2690 - 2697
  • [33] Phase contrast imaging of female breast tissues with synchrotron radiation.
    Park, S. H.
    Kim, H. T.
    Kim, J. K.
    Jheon, S. H.
    Youn, H. S.
    BREAST CANCER RESEARCH AND TREATMENT, 2006, 100 : S128 - S128
  • [34] Effect of Coherence Loss in Differential Phase Contrast Imaging
    Cai, Weixing
    Ning, Ruola
    Liu, Jiangkun
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [35] On the design for a versatile emaging and hard X-ray beamline at the Australian synchrotron: Implementation of in-line phase-contrast imaging
    Wilkins, SW
    Lewis, RA
    Nesterets, Y
    Garrett, RF
    Mayo, SC
    Nugent, KA
    Parry, DJ
    Siu, KKW
    Stevenson, AW
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 380 - 383
  • [36] A phase retrieval algorithm for polychromatic x-ray in-line phase contrast imaging
    Guo, Xue-jun
    Liu, Xiao-lin
    Gu, Mu
    Ni, Chen
    Liu, Bo
    Huang, Shi-ming
    2012 INTERNATIONAL WORKSHOP ON IMAGE PROCESSING AND OPTICAL ENGINEERING, 2012, 8335
  • [37] Optimization of the in-line X-ray phase-contrast imaging setup considering edge-contrast enhancement and spatial resolution
    贾全杰
    陈雨
    黎刚
    姜晓明
    中国物理C, 2012, 36 (03) : 267 - 274
  • [38] Optimization of the in-line X-ray phase-contrast imaging setup considering edge-contrast enhancement and spatial resolution
    Jia Quan-Jie
    Chen Yu
    Li Gang
    Jiang Xiao-Ming
    CHINESE PHYSICS C, 2012, 36 (03) : 267 - 274
  • [39] Hard X-ray in-line outline imaging for blood vessels:first generation synchrotron radiation without contrast agents in vitro
    姜庆军
    冯赟
    肖湘生
    刘士远
    陈敏
    肖体乔
    田玉莲
    朱佩平
    Journal of Medical Colleges of PLA, 2006, (01) : 34 - 37
  • [40] Making Clear the Imperceptible: In-Line X-ray Phase Contrast Imaging
    Gundogdu, O.
    Ismail, E. Che
    Jenneson, R. M.
    Bradley, D. A.
    ADVANCED SCIENCE LETTERS, 2009, 2 (01) : 78 - 80