Effect of spatial coherence on application of in-line phase contrast imaging to synchrotron radiation mammography

被引:26
|
作者
Xiao, TQ [1 ]
Bergamaschi, A
Dreossi, D
Longo, R
Olivo, A
Pani, S
Rigon, L
Rokvic, T
Venanzi, C
Castelli, E
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai Synchrotron Radiat Facil, Shanghai 201800, Peoples R China
[2] Univ Trieste, Dipartimento Fis, Trieste, Italy
[3] Ist Nazl Fis Nucl, Sez Trieste, Trieste, Italy
[4] Univ Belgrade, Fac Phys, Belgrade 11001, Serbia Monteneg
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2005年 / 548卷 / 1-2期
关键词
spatial coherence; phase contrast imaging; mammography; synchrotron radiation;
D O I
10.1016/j.nima.2005.03.083
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Effect of spatial coherence on the application of in-line phase contrast imaging (IL-PCI) to synchrotron radiation (SR) mammography is investigated experimentally at SYRMEP/ELETTRA. Factors that are related to spatial coherence and IL-PCI image quality, which include vertical and horizontal beam, photon energy, slit width, sample-detector distance and detector resolution, are analyzed. The experimental results demonstrate that better IL-PCI image quality could be achieved in the vertical beam. As for the slit width, the spatial coherence for horizontal beam remains almost the same until the slit width is gradually closed to 5 mm. For mammography applications of ILPCI, slit width of 100mm could be employed and high-enough image quality can still be obtained. Lower photon energy results in better coherence and correspondingly better IL-PCI image quality. By compromising the dose and image quality, photon energy of similar to 19 keV is recommended for SR mammography. To preserve the edge enhancement resulting from good coherence of SR, an appropriate sample-detector distance and a practical detector should be selected. The optimum sample-detector distance highly depends on detector resolution. For high-resolution film, the best IL-PCI imaging quality is obtained at a closer sample-detector distance. For an X-ray CCD with pixel size of 14 mu m, about 1.5m is needed to achieve optimum image quality. The large pixel size of the detector will deteriorate the edge-enhancing efficiency and results in lower IL-PCI imaging quality. In practice, the spatial resolution and sensitivity of the detectors should be compromised. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:155 / 162
页数:8
相关论文
共 50 条
  • [21] In-line phase-contrast imaging for strong absorbing objects
    De Caro, Liberato
    Cedola, Alessia
    Giannini, Cinzia
    Bukreeva, Inna
    Lagomarsino, Stefano
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (22): : 6619 - 6637
  • [22] SPATIAL COHERENCE OF SYNCHROTRON-RADIATION
    COISSON, R
    APPLIED OPTICS, 1995, 34 (05): : 904 - 908
  • [23] Effects of incident illumination on in-line phase-contrast imaging
    Gureyev, TE
    Nesterets, YI
    Paganin, DM
    Wilkins, SW
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2006, 23 (01) : 34 - 42
  • [24] Microvoids in Solids: Synchrotron Radiation Phase Contrast Imaging and Simulations
    Kohn, Victor G.
    Argunova, Tatiana S.
    Je, Jung Ho
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2018, 255 (09):
  • [25] Phase retrieval for hard x-ray in-line phase contrast imaging
    Yu, Bin
    Peng, Xiang
    Tian, Jin-Dong
    Niu, Han-Ben
    Wuli Xuebao/Acta Physica Sinica, 2005, 54 (05): : 2034 - 2037
  • [26] Imaging Performance of Synchrotron X-ray In-line Phase Contrast Tomography for Visualization of Implanted Hydrogel Cardiac Constructs
    Izadifar, M.
    Kelly, M. E.
    Chen, X. B.
    TISSUE ENGINEERING PART A, 2016, 22 : S33 - S33
  • [27] Phase retrieval for hard x-ray in-line phase contrast imaging
    Yu, B
    Peng, X
    Tian, JD
    Niu, HB
    ACTA PHYSICA SINICA, 2005, 54 (05) : 2034 - 2037
  • [28] Microbubbles as contrast agent for in-line x-ray phase-contrast imaging
    Xi, Yan
    Tang, Rongbiao
    Wang, Yujie
    Zhao, Jun
    APPLIED PHYSICS LETTERS, 2011, 99 (01)
  • [29] Experiment of in-line X-ray phase-contrast imaging
    Gong, Shao-Run
    Gao, Feng
    Xu, Ya-Jie
    Liu, Hong
    Nami Jishu yu Jingmi Gongcheng/Nanotechnology and Precision Engineering, 2010, 8 (01): : 63 - 69
  • [30] Quantitative in-line phase-contrast imaging with multienergy x rays
    Gureyev, TE
    Mayo, S
    Wilkins, SW
    Paganin, D
    Stevenson, AW
    PHYSICAL REVIEW LETTERS, 2001, 86 (25) : 5827 - 5830