Effect of spatial coherence on application of in-line phase contrast imaging to synchrotron radiation mammography

被引:26
|
作者
Xiao, TQ [1 ]
Bergamaschi, A
Dreossi, D
Longo, R
Olivo, A
Pani, S
Rigon, L
Rokvic, T
Venanzi, C
Castelli, E
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai Synchrotron Radiat Facil, Shanghai 201800, Peoples R China
[2] Univ Trieste, Dipartimento Fis, Trieste, Italy
[3] Ist Nazl Fis Nucl, Sez Trieste, Trieste, Italy
[4] Univ Belgrade, Fac Phys, Belgrade 11001, Serbia Monteneg
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2005年 / 548卷 / 1-2期
关键词
spatial coherence; phase contrast imaging; mammography; synchrotron radiation;
D O I
10.1016/j.nima.2005.03.083
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Effect of spatial coherence on the application of in-line phase contrast imaging (IL-PCI) to synchrotron radiation (SR) mammography is investigated experimentally at SYRMEP/ELETTRA. Factors that are related to spatial coherence and IL-PCI image quality, which include vertical and horizontal beam, photon energy, slit width, sample-detector distance and detector resolution, are analyzed. The experimental results demonstrate that better IL-PCI image quality could be achieved in the vertical beam. As for the slit width, the spatial coherence for horizontal beam remains almost the same until the slit width is gradually closed to 5 mm. For mammography applications of ILPCI, slit width of 100mm could be employed and high-enough image quality can still be obtained. Lower photon energy results in better coherence and correspondingly better IL-PCI image quality. By compromising the dose and image quality, photon energy of similar to 19 keV is recommended for SR mammography. To preserve the edge enhancement resulting from good coherence of SR, an appropriate sample-detector distance and a practical detector should be selected. The optimum sample-detector distance highly depends on detector resolution. For high-resolution film, the best IL-PCI imaging quality is obtained at a closer sample-detector distance. For an X-ray CCD with pixel size of 14 mu m, about 1.5m is needed to achieve optimum image quality. The large pixel size of the detector will deteriorate the edge-enhancing efficiency and results in lower IL-PCI imaging quality. In practice, the spatial resolution and sensitivity of the detectors should be compromised. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:155 / 162
页数:8
相关论文
共 50 条
  • [1] Study of micropores in single crystals by in-line phase contrast imaging with synchrotron radiation
    Argunova, T. S.
    Kohn, V. G.
    PHYSICS-USPEKHI, 2019, 62 (06) : 602 - 616
  • [2] In-line phase contrast in synchrotron-radiation microradiography and tomography
    Weitkamp, T
    Rau, C
    Snigirev, AA
    Benner, B
    Günzler, TF
    Kuhlmann, M
    Schroer, CG
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 92 - 102
  • [3] Developing a Microbubble-Based Contrast Agent for Synchrotron In-Line Phase Contrast Imaging
    Ngoc Ton
    Goncin, Una
    Panahifar, Arash
    Chapman, Dean
    Wiebe, Sheldon
    Machtaler, Steven
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (05) : 1527 - 1535
  • [4] In-line phase-contrast breast tomosynthesis: a phantom feasibility study at a synchrotron radiation facility
    Bliznakova, K.
    Russo, P.
    Kamarianakis, Z.
    Mettivier, G.
    Requardt, H.
    Bravin, A.
    Buliev, I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (16): : 6243 - 6263
  • [5] Mammography with synchrotron radiation: Advantages brought by monochromaticity, energy tuneability and spatial coherence
    Arfelli, F
    Bonvicini, V
    Bravin, A
    Cantatore, G
    Castelli, E
    Dalla Palma, L
    Di Michiel, M
    Fabrizioli, M
    Longo, R
    Olivo, A
    Pani, S
    Pontoni, D
    Poropat, P
    Prest, M
    Rashevsky, A
    Rigon, L
    Tromba, G
    Vacchi, A
    Vallazza, E
    EDXRS-98: PROCEEDINGS OF THE EUROPEAN CONFERENCE ON ENERGY DISPERSIVE X-RAY SPECTROMETRY 1998, 1999, : 225 - 230
  • [6] Phase contrast mammography with synchrotron radiation: Physical aspects of the clinical trial
    Longo, R.
    Abrami, A.
    Arfellia, F.
    Bregant, P.
    Chenda, V.
    Cova, M. A.
    Dreossi, D.
    de Guarrini, F.
    Menk, R. H.
    Quai, E.
    Quaia, E.
    Rokvic, T.
    Tonutti, M.
    Tromba, G.
    Zanconati, F.
    Castelli, E.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [7] Noise Reduction in Phase-Contrast Mammography Images with Synchrotron Radiation
    Ruiz-Gonzalez, Yusely
    Brizuela-Cardoso, Javier D.
    Perez-Diaz, Marlen
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 361 - 366
  • [8] Objective measurements of image quality in synchrotron radiation phase-contrast imaging versus digital mammography
    Y. Ruiz-Gonzalez
    M. Perez-Diaz
    D. Martínez-Aguila
    M. Diaz-Barreto
    I. Fleitas
    R. Mora-Machado
    L. Rigon
    G. Tromba
    P. Bregant
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 181 - 188
  • [9] Objective measurements of image quality in synchrotron radiation phase-contrast imaging versus digital mammography
    Ruiz-Gonzalez, Y.
    Perez-Diaz, M.
    Martinez-Aguila, D.
    Diaz-Barreto, M.
    Fleitas, I.
    Mora-Machado, R.
    Rigon, L.
    Tromba, G.
    Bregant, P.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (02) : 181 - 188
  • [10] Simulation of phase retrieval algorithms for in-line phase contrast imaging
    Zhu Hao
    Fu Jian
    Li Bin
    Zhou Xingyu
    Jiang Baihong
    ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 1954 - 1957