Voltammetric detection of copper(II) at a carbon paste electrode containing an organically modified silica

被引:125
|
作者
Etienne, M [1 ]
Bessiere, J [1 ]
Walcarius, A [1 ]
机构
[1] Univ Nancy 1, CNRS, UMR 7564, Lab Chim Phys Environm, F-54600 Villers Les Nancy, France
关键词
copper(II); aminopropyl-grafted silica gel; carbon paste; preconcentration; voltammetric detection;
D O I
10.1016/S0925-4005(01)00614-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A carbon paste electrode modified with aminopropyl-grafted silica gel (APS) was evaluated as an electrochemical sensor for copper species in aqueous medium. The overall analysis involved a two-step procedure: an accumulation step at open circuit, followed by medium exchange to a pure electrolyte solution for the voltammetric quantification. During the preconcentration step, copper(II) was accumulated on the APS surface by complexation with the amine groups. In the detection step, copper(II) was desorbed in acidic medium, then cathodically electrolyzed at -0.5 V for 60 s, and detected by anodic stripping square wave voltammetry. The influence of various experimental parameters on the sensor response was investigated (i.e. pH of the detection and accumulation media, electrolysis time, carbon paste composition, silica gel porosity, accumulation time). Reproducible results were obtained, giving after optimization a linear calibration in the 5 x 10(-8)-2 x 10(-7) M concentration range, with a detection limit of 3 x 10(-9) M. This new sensor was applied to copper analysis in laboratory tap water. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:531 / 538
页数:8
相关论文
共 50 条
  • [41] Maize tassel-modified carbon paste electrode for voltammetric determination of Cu(II)
    Moyo, Mambo
    Okonkwo, Jonathan O.
    Agyei, Nana M.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2014, 186 (08) : 4807 - 4817
  • [42] Voltammetric Determination of Pb(II) Ions at a Modified Kaolinite-Carbon Paste Electrode
    Seyi P. Akanji
    Omotayo A. Arotiba
    Duduzile Nkosi
    Electrocatalysis, 2019, 10 : 643 - 652
  • [43] Voltammetric Determination of Pb(II) Ions at a Modified Kaolinite-Carbon Paste Electrode
    Akanji, Seyi P.
    Arotiba, Omotayo A.
    Nkosi, Duduzile
    ELECTROCATALYSIS, 2019, 10 (06) : 643 - 652
  • [44] Voltammetric determination of lead (II) ions at carbon paste electrode modified with banana tissue
    Institute of Chemistry, University of the Philippines, Los Baños, Philippines
    J. Appl. Sci., 2007, 9 (1286-1292):
  • [46] Voltammetric Monitoring of Pb (II) by TiO2 Modified Carbon Paste Electrode
    Belkhamsa, Najet
    Ouattara, Lassine
    Ksibi, Mohamed
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2015, 162 (08) : B212 - B216
  • [47] Maize tassel-modified carbon paste electrode for voltammetric determination of Cu(II)
    Mambo Moyo
    Jonathan O. Okonkwo
    Nana M. Agyei
    Environmental Monitoring and Assessment, 2014, 186 : 4807 - 4817
  • [48] Acetanilide Modified Carbon Paste Electrode for the Electrochemical Detection of Dopamine: A Cyclic Voltammetric Study
    Shankar, Sarojini Sharath
    Swamy, Bahaddurghatta E. Kumara
    Mahanthesha, Kurangalara R.
    Sathisha, Tammanekar, V
    Vishwanath, Chandrashekar C.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (01): : 19 - 31
  • [49] Clay modified carbon paste electrode for the voltammetric detection of dopamine in presence of ascorbic acid
    Sathisha, Tammanekar V.
    Swamy, Bahaddurghatta E. Kumara
    Reddy, Sathish
    Chandrashekar, Bananakere N.
    Eswarappa, Bheemappa
    JOURNAL OF MOLECULAR LIQUIDS, 2012, 172 : 53 - 58
  • [50] Voltammetric detection of As(III) with Porphyridium cruentum based modified carbon paste electrode biosensor
    Zaib, M.
    Saeed, A.
    Hussain, I.
    Athar, M. M.
    Iqbal, M.
    BIOSENSORS & BIOELECTRONICS, 2014, 62 : 242 - 248