Voltammetric detection of copper(II) at a carbon paste electrode containing an organically modified silica

被引:125
|
作者
Etienne, M [1 ]
Bessiere, J [1 ]
Walcarius, A [1 ]
机构
[1] Univ Nancy 1, CNRS, UMR 7564, Lab Chim Phys Environm, F-54600 Villers Les Nancy, France
关键词
copper(II); aminopropyl-grafted silica gel; carbon paste; preconcentration; voltammetric detection;
D O I
10.1016/S0925-4005(01)00614-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A carbon paste electrode modified with aminopropyl-grafted silica gel (APS) was evaluated as an electrochemical sensor for copper species in aqueous medium. The overall analysis involved a two-step procedure: an accumulation step at open circuit, followed by medium exchange to a pure electrolyte solution for the voltammetric quantification. During the preconcentration step, copper(II) was accumulated on the APS surface by complexation with the amine groups. In the detection step, copper(II) was desorbed in acidic medium, then cathodically electrolyzed at -0.5 V for 60 s, and detected by anodic stripping square wave voltammetry. The influence of various experimental parameters on the sensor response was investigated (i.e. pH of the detection and accumulation media, electrolysis time, carbon paste composition, silica gel porosity, accumulation time). Reproducible results were obtained, giving after optimization a linear calibration in the 5 x 10(-8)-2 x 10(-7) M concentration range, with a detection limit of 3 x 10(-9) M. This new sensor was applied to copper analysis in laboratory tap water. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:531 / 538
页数:8
相关论文
共 50 条
  • [31] Voltammetric detection of silver(I) using a carbon paste electrode modified with keratin
    Sugawara, K
    Matsui, H
    Hoshi, S
    Akatsuka, K
    ANALYST, 1998, 123 (10) : 2013 - 2016
  • [32] Carbon paste electrode modified with ferrimagnetic nanoparticles for voltammetric detection of the hormone estriol
    da Silveira, Jonas Pires
    Piovesan, Jamille Valeria
    Spinelli, Almir
    MICROCHEMICAL JOURNAL, 2017, 133 : 22 - 30
  • [33] Development of a novel carbon paste electrode containing a natural zeolite for the voltammetric determination of copper
    Alpat, SK
    Yuksel, U
    Akcay, H
    ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (02) : 130 - 134
  • [34] Silica gel modified carbon paste electrode for electrochemical detection of insulin
    Jaafariasl, Mehdi
    Shams, Esmaeil
    Amini, Mohammad Kazem
    ELECTROCHIMICA ACTA, 2011, 56 (11) : 4390 - 4395
  • [35] Anodic stripping voltammetric detection of mercury(II) using Au-PEDOT modified carbon paste electrode
    Anandhakumar, S.
    Mathiyarasu, J.
    Phani, K. L. N.
    ANALYTICAL METHODS, 2012, 4 (08) : 2486 - 2489
  • [36] Stripping voltammetric determiantion of copper (II) with tetrahydroxyanthraquione-activated carbon paste electrode
    Qi, JR
    Li, Z
    Xu, HD
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (12) : 1740 - 1742
  • [38] Silica-modified carbon paste electrode for copper determination in ammoniacal medium
    Walcarius, A
    Bessiere, J
    ELECTROANALYSIS, 1997, 9 (09) : 707 - 713
  • [39] VOLTAMMETRIC BEHAVIOR OF CYSTEINE BY A CARBON-PASTE ELECTRODE CONTAINING A COBALT(II) CYCLOHEXYLBUTYRATE
    SUGAWARA, K
    TANAKA, S
    TAGA, M
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1991, 26 (03): : 469 - 474
  • [40] Anodic stripping voltammetric determination of copper(II) using a functionalized carbon nanotubes paste electrode modified with crosslinked chitosan
    Janegitz, Bruno C.
    Marcolino-Junior, Luiz H.
    Campana-Filho, Sergio P.
    Faria, Ronaldo C.
    Fatibello-Filho, Orlando
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 142 (01) : 260 - 266