Trabecular deformations during screw pull-out: a micro-CT study of lapine bone

被引:25
|
作者
Joffre, Thomas [1 ,2 ]
Isaksson, Per [2 ]
Procter, Philip [1 ]
Persson, Cecilia [1 ]
机构
[1] Uppsala Univ, Div Appl Mat Sci, Dept Engn Sci, Mat Med Grp, Uppsala, Sweden
[2] Uppsala Univ, Dept Engn Sci, Appl Mech, Uppsala, Sweden
关键词
Screws; Implants; Trabecular bone; Pull-out test; Digital volume correlation; Micro-CT; DIGITAL VOLUME CORRELATION; CALCIUM-PHOSPHATE CEMENT; CANCELLOUS BONE; BIOMECHANICAL EVALUATION; OSTEOPOROTIC BONE; IMPLANT STABILITY; AUGMENTATION; FIXATION; STRAIN; STRENGTH;
D O I
10.1007/s10237-017-0891-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The mechanical fixation of endosseous implants, such as screws, in trabecular bone is challenging because of the complex porous microstructure. Development of new screw designs to improve fracture fixation, especially in high-porosity osteoporotic bone, requires a profound understanding of how the structural system implant/trabeculae interacts when it is subjected to mechanical load. In this study, pull-out tests of screw implants were performed. Screws were first inserted into the trabecular bone of rabbit femurs and then pulled out from the bone inside a computational tomography scanner. The tests were interrupted at certain load steps to acquire 3D images. The images were then analysed with a digital volume correlation technique to estimate deformation and strain fields inside the bone during the tests. The results indicate that the highest shear strains are concentrated between the inner and outer thread diameter, whereas compressive strains are found at larger distances from the screw. Tensile strains were somewhat smaller. Strain concentrations and the location of trabecular failures provide experimental information that could be used in the development of new screw designs and/or to validate numerical simulations.
引用
收藏
页码:1349 / 1359
页数:11
相关论文
共 50 条
  • [1] Trabecular deformations during screw pull-out: a micro-CT study of lapine bone
    Thomas Joffre
    Per Isaksson
    Philip Procter
    Cecilia Persson
    Biomechanics and Modeling in Mechanobiology, 2017, 16 : 1349 - 1359
  • [2] Comparison of the Pull-out Strength Between a Novel Micro-dynamic Pedicle Screw and a Traditional Pedicle Screw by Using Pull Out Test and Micro-CT
    Lei Qian
    Weidong Cheng
    Jun Ouyang
    医用生物力学, 2019, 34(S1) (S1) : 56 - 56
  • [3] Automatic thresholding of micro-CT trabecular bone images
    Zhang, Yongping
    He, Zhongkun
    Fan, Shaojing
    He, Kejia
    Li, Chen
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 23 - +
  • [4] Influence of segmentation on micro-CT images of trabecular bone
    Tassani, S.
    Korfiatis, V.
    Matsopoulos, G. K.
    JOURNAL OF MICROSCOPY, 2014, 256 (02) : 75 - 81
  • [5] A Computational Approximation to Model Variation in Cancellous Bone Screw Pull-Out
    Piper, A.
    Brown, C. J.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (02):
  • [6] Effects of bone materials on the screw pull-out strength in human spine
    Zhang, Qing Hang
    Tan, Soon Huat
    Chou, Siaw Meng
    MEDICAL ENGINEERING & PHYSICS, 2006, 28 (08) : 795 - 801
  • [7] Analysis of fatigue behaviour of single steel fibre pull-out in a concrete matrix with micro-CT and acoustic emission
    De Smedt, M.
    Van Steen, C.
    DeWilder, K.
    Vandewalle, L.
    Verstrynge, E.
    LIFE-CYCLE ANALYSIS AND ASSESSMENT IN CIVIL ENGINEERING: TOWARDS AN INTEGRATED VISION, 2019, : 2389 - 2396
  • [8] 3D pull-out finite element simulation of the pedicle screw-trabecular bone interface at strain rates
    Cetin, Ahmet
    Bircan, Durmus Ali
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2022, 236 (01) : 134 - 144
  • [9] Micro-CT characterization of human trabecular bone in osteogenesis imperfecta
    Jameson, John
    Albert, Carolyne
    Smith, Peter
    Molthen, Robert
    Harris, Gerald
    MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [10] Trabecular bone ratio of the mandibular condyle according to the presence of teeth: a micro-CT study
    D. Y. Choi
    K. H. Sun
    S. Y. Won
    J. G. Lee
    K. S. Hu
    K. D. Kim
    H. J. Kim
    Surgical and Radiologic Anatomy, 2012, 34 : 519 - 526