Trabecular deformations during screw pull-out: a micro-CT study of lapine bone

被引:25
|
作者
Joffre, Thomas [1 ,2 ]
Isaksson, Per [2 ]
Procter, Philip [1 ]
Persson, Cecilia [1 ]
机构
[1] Uppsala Univ, Div Appl Mat Sci, Dept Engn Sci, Mat Med Grp, Uppsala, Sweden
[2] Uppsala Univ, Dept Engn Sci, Appl Mech, Uppsala, Sweden
关键词
Screws; Implants; Trabecular bone; Pull-out test; Digital volume correlation; Micro-CT; DIGITAL VOLUME CORRELATION; CALCIUM-PHOSPHATE CEMENT; CANCELLOUS BONE; BIOMECHANICAL EVALUATION; OSTEOPOROTIC BONE; IMPLANT STABILITY; AUGMENTATION; FIXATION; STRAIN; STRENGTH;
D O I
10.1007/s10237-017-0891-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The mechanical fixation of endosseous implants, such as screws, in trabecular bone is challenging because of the complex porous microstructure. Development of new screw designs to improve fracture fixation, especially in high-porosity osteoporotic bone, requires a profound understanding of how the structural system implant/trabeculae interacts when it is subjected to mechanical load. In this study, pull-out tests of screw implants were performed. Screws were first inserted into the trabecular bone of rabbit femurs and then pulled out from the bone inside a computational tomography scanner. The tests were interrupted at certain load steps to acquire 3D images. The images were then analysed with a digital volume correlation technique to estimate deformation and strain fields inside the bone during the tests. The results indicate that the highest shear strains are concentrated between the inner and outer thread diameter, whereas compressive strains are found at larger distances from the screw. Tensile strains were somewhat smaller. Strain concentrations and the location of trabecular failures provide experimental information that could be used in the development of new screw designs and/or to validate numerical simulations.
引用
收藏
页码:1349 / 1359
页数:11
相关论文
共 50 条
  • [21] Correlation of bone equivalent mineral density to pull-out resistance of triangulated pedicle screw construct
    Hadjipavlou, AG
    Nicodemus, CL
    AlHamdan, FA
    Simmons, JW
    Pope, MH
    JOURNAL OF SPINAL DISORDERS, 1997, 10 (01): : 12 - 19
  • [22] On estimating the directionality distribution in pedicle trabecular bone from micro-CT images
    Gdyczynski, Catherine M.
    Manbachi, Amir
    Hashemi, SayedMasoud
    Lashkari, Bahman
    Cobbold, Richard S. C.
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (12) : 2415 - 2428
  • [23] Characterization of Human Cortical and Trabecular Bone Structural Change by NMR and Micro-CT
    Ni, Qingwen
    Bredbenner, Todd
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 545 - 546
  • [24] A comparative evaluation of cone beam CT and micro-CT on trabecular bone structures in the human mandible
    Van Dessel, J.
    Huang, Y.
    Depypere, M.
    Rubira-Bullen, I.
    Maes, F.
    Jacobs, R.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (08)
  • [25] Multislice-CT for structure - Analysis of trabecular bone - a comparison with Micro-CT and biomechanical strength
    Bauer, JS
    Issever, AS
    Fischbeck, M
    Burghardt, A
    Eckstein, F
    Rummeny, EJ
    Majumdar, S
    Link, TM
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (05): : 709 - 718
  • [26] Comparison of the Pull-Out Strength between a Novel Micro-Dynamic Pedicle Screw and a Traditional Pedicle Screw in Lumbar Spine
    Qian, Lei
    Chen, Weidong
    Li, Peng
    Qu, Dongbin
    Liang, Wenjie
    Zheng, Minghui
    Ouyang, Jun
    ORTHOPAEDIC SURGERY, 2020, 12 (04) : 1285 - 1292
  • [27] Ideal position of hip lag screw within the femoral head of osteoporotic hip fractures: Based on micro-CT analysis of the trabecular bone
    Won, Y. -Y.
    Park, Y. -S.
    Ji, H. -M.
    Kim, B. -S.
    Moon, K. -H.
    BONE, 2011, 48 : S177 - S177
  • [28] Revising a loosened cancellous screw with a larger screw does not restore original pull-out strength - A biomechanical study
    Seng, Daniel W. R.
    Chou, Siaw Meng
    Liang, Benjamin Z. R.
    Tan, Alvin C. K.
    CLINICAL BIOMECHANICS, 2021, 89
  • [29] Comparative Pull-Out Performances of Cephalomedullary Nail with Screw and Helical Blade According to Femur Bone Densities
    Park, Young-Chang
    Chae, Dong-Sik
    Kang, Kyung-Yil
    Ding, Yao
    Park, Sung-Jun
    Yoon, Jonghun
    APPLIED SCIENCES-BASEL, 2021, 11 (02): : 1 - 12
  • [30] In vitro biomechanical study of pedicle screw pull-out strength based on different screw path preparation techniques
    Moldavsky, Mark
    Salloum, Kanaan
    Bucklen, Brandon
    Khalil, Saif
    Mehta, Jwalant S.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2016, 50 (02) : 177 - 182