ANALYSIS OF INFLUENCE OF FCB TEST ON 1000MW STEAM TURBINE SAFETY

被引:0
|
作者
Xie, Dan-mei [1 ]
Yang, Yi [1 ]
Chen, Chang [1 ]
Hu, Peng-fei [1 ]
Guo, Jie [1 ]
Jiang, Wei [1 ]
机构
[1] Wuhan Univ, Wuhan 430072, Hubei, Peoples R China
关键词
fast cut back; safety; steam turbine; prediction; water level; exhausted steam temperature;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The capacity of power grid in China increases rapidly. Because of the reliability of multi-infeed DC system in the grid, power system damping is relatively weak. Realizing isolated island operation of thermal power units with FCB (fast cut back) ability is considered to be the best solution of quick restoration of power grid. Taking a 1000MW USC(Ultra-supercritical) unit as an example, based on the data of the unit's load refection tests, this paper conducts a look at several aspects of research: (1)predicting the maximum speed rise of rotor during FCB process with different loads by using Simulink; (2)predicting the water level of deaerator and condenser during FCB process with different loads by same method; (3)predicting the highest exhausted steam temperature of HP cylinder during FCB process with different loads by using FEM; (4)comparing these key parameters with FCB test data, it shows that the predicted results agree with test data very well. (5)analyzing the influence of FCB test on the safety and life loss of the thermal equipment.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Design of 600°C class 1000 MW steam turbine
    Obara, I
    Tanaka, Y
    Magoshi, R
    Yokota, H
    Shige, T
    Takita, K
    [J]. JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1998, 41 (03) : 734 - 739
  • [22] 1000MW超超临界机组FCB工况下凝汽器水位仿真研究
    韩鹏飞
    胡念苏
    万祥
    吕春杰
    魏冰洁
    [J]. 汽轮机技术, 2015, (02) : 121 - 124
  • [23] The Research on Application of 1000MW Unit Boiler Safety System
    Zheng Yue-Xia
    Li Hui-Qiang
    Wang Xu-Hui
    [J]. MODERN TECHNOLOGIES IN MATERIALS, MECHANICS AND INTELLIGENT SYSTEMS, 2014, 1049 : 626 - 629
  • [24] 1000MW级机组实现FCB功能的热力系统配置
    石佳
    [J]. 科技资讯, 2008, (31) : 126 - 127
  • [25] 国华台电1000MW机组FCB技术汽轮机系统应对策略
    宋勇
    高志华
    [J]. 中国煤炭, 2014, 40(S1) (S1) : 235 - 238
  • [26] Unbalance response of 1000MW ultra supercritical turbine with single bearing support
    [J]. Gao, Q.-S. (qqshui@aliyan.com), 1600, Chinese Vibration Engineering Society (33):
  • [27] 宁海电厂1000MW机组RB与FCB控制策略的设计和应用
    吴永存
    朱介南
    [J]. 电力建设, 2011, 32 (01) : 59 - 63
  • [28] Advanced 1000 MW tandem-compound reheat steam turbine
    Oeynhausen, H
    Drosdziok, A
    Ulm, W
    Termuehlen, H
    [J]. PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 58, PTS I AND II, 1996, 58 : 686 - 698
  • [29] 1000 MW ultra-supercritical turbine steam parameter optimization
    Feng W.
    [J]. Frontiers of Energy and Power Engineering in China, 2008, 2 (2): : 187 - 193
  • [30] Cause Analysis and Treatment of Seawater leaking into Lubricating Oil System of 1000 MW Steam Turbine
    Chen, Suhong
    Yu, Naihai
    Han, Zhijun
    Gao, Feng
    Zhang, Lei
    Pang, Xiangkun
    Yun, Yuxin
    [J]. 2018 4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2019, 252