Cause Analysis and Treatment of Seawater leaking into Lubricating Oil System of 1000 MW Steam Turbine

被引:0
|
作者
Chen, Suhong [1 ]
Yu, Naihai [1 ]
Han, Zhijun [2 ]
Gao, Feng [3 ]
Zhang, Lei [1 ]
Pang, Xiangkun [1 ]
Yun, Yuxin [1 ]
机构
[1] State Grid Shandong Elect Power Res Inst, Jinan 250003, Shandong, Peoples R China
[2] State Grid Shandong Elect Power Co, Jinan 250001, Shandong, Peoples R China
[3] State Grid Licheng Power Supply Co, Jinan 250100, Shandong, Peoples R China
关键词
D O I
10.1088/1755-1315/252/3/032061
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper mainly analyzes the reason of seawater leaking into lubricating oil system of one 1000 MW unit in some coastal power plant in Shandong province and presents the corresponding treatment measure. Dissolving elution method is proposed to determine the chlorine ion content in the oil, to judge whether oil entrained water is cleaned. By the oil filter processing, the moisture content of turbine oil fall from 24414 mg/L to 10.1 mg/L, the chloride ion content is from 155 mg/L down to not detected. The serious pollution of the seawater leakage returns to normal in a short time, which ensured the safe operation of the unit, avoided the malignant accidents after treatment in time.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Experimental investigation of the steam wetness in a 1000 MW steam turbine
    Kolovratnik, Michal
    Bartos, Ondrej
    [J]. EFM15 - EXPERIMENTAL FLUID MECHANICS 2015, 2016, 114
  • [2] Failure Analysis of Plate Perforation of Steam Turbine Lubricating Oil Cooler
    Zhou, C. L.
    Fan, Z. D.
    Dong, H. N.
    Yan, A. J.
    [J]. JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2021, 21 (06) : 2160 - 2169
  • [3] Practical contaminant analysis of lubricating oil in a steam turbine-generator
    Ahn, HS
    Yoon, ES
    Sohn, DG
    Kwon, OK
    Shin, KS
    Nam, CH
    [J]. TRIBOLOGY INTERNATIONAL, 1996, 29 (02) : 161 - 168
  • [4] Failure Analysis of Plate Perforation of Steam Turbine Lubricating Oil Cooler
    C. L. Zhou
    Z. D. Fan
    H. N. Dong
    A. J. Yan
    [J]. Journal of Failure Analysis and Prevention, 2021, 21 : 2160 - 2169
  • [5] Practical contaminant analysis of lubricating oil in a steam turbine-generator
    Korea Inst of Science and Technology
    [J]. Tribol Int, 2 (161-168):
  • [6] PRODUCTION TECHNICAL TREND OF STEAM TURBINE-GENERATORS AND LUBRICATING OIL SYSTEM
    MIMURO, H
    [J]. JOURNAL OF JAPAN SOCIETY OF LUBRICATION ENGINEERS, 1980, 25 (10): : 654 - 659
  • [7] ANALYSIS OF INFLUENCE OF FCB TEST ON 1000MW STEAM TURBINE SAFETY
    Xie, Dan-mei
    Yang, Yi
    Chen, Chang
    Hu, Peng-fei
    Guo, Jie
    Jiang, Wei
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2014, VOL 14, 2015,
  • [8] Use of JKTH-1000DEH system in a 50 MW steam turbine unit
    Liu, Dingyuan
    [J]. Reneng Dongli Gongcheng/Journal of Engineering for Thermal Energy and Power, (03): : 221 - 225
  • [9] Design of 600°C class 1000 MW steam turbine
    Obara, I
    Tanaka, Y
    Magoshi, R
    Yokota, H
    Shige, T
    Takita, K
    [J]. JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1998, 41 (03) : 734 - 739
  • [10] Advanced 1000 MW tandem-compound reheat steam turbine
    Oeynhausen, H
    Drosdziok, A
    Ulm, W
    Termuehlen, H
    [J]. PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 58, PTS I AND II, 1996, 58 : 686 - 698