Dosimetric validation of the Acuros XB Advanced Dose Calculation algorithm: fundamental characterization in water

被引:76
|
作者
Fogliata, Antonella [1 ]
Nicolini, Giorgia [1 ]
Clivio, Alessandro [1 ]
Vanetti, Eugenio [1 ]
Mancosu, Pietro [2 ]
Cozzi, Luca [1 ]
机构
[1] Oncol Inst So Switzerland, Med Phys Unit, Bellinzona, Switzerland
[2] Ist Clin Humanitas, Radio Oncol Dept, Milan, Italy
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 06期
关键词
ANISOTROPIC ANALYTICAL ALGORITHM; TREATMENT PLANNING SYSTEMS; RADIATION-THERAPY; QUALITY-ASSURANCE; PHOTON BEAMS; RADIOTHERAPY; VERIFICATION; OPTIMIZATION; PARAMETERS; ACCURACY;
D O I
10.1088/0031-9155/56/6/022
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new algorithm, Acuros (R) XB Advanced Dose Calculation, has been introduced by Varian Medical Systems in the Eclipse planning system for photon dose calculation in external radiotherapy. Acuros XB is based on the solution of the linear Boltzmann transport equation (LBTE). The LBTE describes the macroscopic behaviour of radiation particles as they travel through and interact with matter. The implementation of Acuros XB in Eclipse has not been assessed; therefore, it is necessary to perform these preclinical validation tests to determine its accuracy. This paper summarizes the results of comparisons of Acuros XB calculations against measurements and calculations performed with a previously validated dose calculation algorithm, the Anisotropic Analytical Algorithm (AAA). The tasks addressed in this paper are limited to the fundamental characterization of Acuros XB in water for simple geometries. Validation was carried out for four different beams: 6 and 15 MV beams from a Varian Clinac 2100 iX, and 6 and 10 MV 'flattening filter free' (FFF) beams from a TrueBeam linear accelerator. The TrueBeam FFF are new beams recently introduced in clinical practice on general purpose linear accelerators and have not been previously reported on. Results indicate that Acuros XB accurately reproduces measured and calculated (with AAA) data and only small deviations were observed for all the investigated quantities. In general, the overall degree of accuracy for Acuros XB in simple geometries can be stated to be within 1% for open beams and within 2% for mechanical wedges. The basic validation of the Acuros XB algorithm was therefore considered satisfactory for both conventional photon beams as well as for FFF beams of new generation linacs such as the Varian TrueBeam.
引用
收藏
页码:1879 / 1904
页数:26
相关论文
共 50 条
  • [1] Dosimetric validation of the Acuros XB Advanced Dose Calculation algorithm: fundamental characterization in water (vol 56, pg 1879, 2011)
    Fogliata, Antonella
    Nicolini, Giorgia
    Clivio, Alessandro
    Vanetti, Eugenio
    Mancosu, Pietro
    Cozzi, Luca
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (09): : 2885 - 2886
  • [2] Dosimetric Validation of Acuros XB Algorithm for Photon Dose Calculation in Water
    Kumar, L.
    Yadav, G.
    Kishore, V.
    Bhushan, M.
    Samuvel, K.
    Suhail, M.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3562 - 3562
  • [3] Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media
    Antonella Fogliata
    Giorgia Nicolini
    Alessandro Clivio
    Eugenio Vanetti
    Luca Cozzi
    [J]. Radiation Oncology, 6
  • [4] Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media
    Fogliata, Antonella
    Nicolini, Giorgia
    Clivio, Alessandro
    Vanetti, Eugenio
    Cozzi, Luca
    [J]. RADIATION ONCOLOGY, 2011, 6
  • [5] Dosimetric Evaluation of Acuros XB Advanced Dose Calculation Algorithm in Head and Neck Patients
    Faught, A.
    Wu, Q.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3406 - 3406
  • [6] Dosimetric Evaluation with Heterogeneity in Acuros XB Advanced Dose Calculation Algorithm and Anisotropic Analytical Algorithm (AAA)
    Rana, S.
    Rogers, K.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3827 - 3827
  • [7] Dosimetric impact of Acuros XB Dose Calculation Algorithm on lung SBRT treatments
    Munoz Montplet, C.
    Agramunt Chaler, S.
    Jurado Bruggeman, D.
    Romera Martinez, I.
    Oliva, E.
    Fuentes, R.
    Rosello, A.
    Aunon, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S772 - S773
  • [8] Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: fundamental characterization in water
    Fogliata, A
    Nicolini, G
    Vanetti, E
    Clivio, A
    Cozzi, L
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06): : 1421 - 1438
  • [9] Dosimetric impact of Acuros XB dose calculation algorithm in prostate cancer treatment using RapidArc
    Rana, Suresh
    Rogers, Kevin
    Lee, Terry
    Reed, Daniel
    Biggs, Christopher
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2013, 9 (03) : 430 - 435
  • [10] The Accuracy of the Acuros XB Advanced Dose Calculation Algorithm for IMRT Dose Distributions in Head and Neck
    Araki, F.
    Onizuka, R.
    Ohno, T.
    Tomiyama, Y.
    Hioki, K.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 296 - 296