Optic axis determination by fibre-based polarization-sensitive swept-source optical coherence tomography

被引:18
|
作者
Lu, Zenghai [1 ]
Kasaragod, Deepa K. [1 ]
Matcher, Stephen J. [1 ]
机构
[1] Univ Sheffield, Dept Mat Sci & Engn, Kroto Res Inst, Sheffield S3 7HQ, S Yorkshire, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 04期
基金
英国工程与自然科学研究理事会;
关键词
HIGH-SPEED; SPECTRAL-DOMAIN; MAINTAINING FIBER; HUMAN RETINA; IN-VIVO; BIREFRINGENCE; MODULATION; CARTILAGE; ORIENTATION; PERFORMANCE;
D O I
10.1088/0031-9155/56/4/014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe a fibre-based variable-incidence angle (VIA) polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) system to determine the 3D optical axis of birefringent biological tissues. Single-plane VIA-PS-OCT is also explored which requires measurement of the absolute fast-axis orientation. A state-of-the-art PS-SS-OCT system with some improvements both in hardware and software was used to determine the apparent optical birefringence of equine tendon for a number of different illumination directions. Polar and azimuthal angles of cut equine tendon were produced by the VIA method and compared with the nominal values. A quarter waveplate (QWP) and equine tendon were used as test targets to validate the fast-axis measurements using the system. Polar and azimuthal angles of cut equine tendon broadly agreed with the expected values within about 8% of the nominal values. A theoretical and experimental analysis of the effect of the sample arm fibre on determination of optical axis orientation using a proposed definition based on the orientation of the eigenpolarization ellipse experimentally confirms that this algorithm only works correctly for special settings of the sample arm fibre. A proposed algorithm based on the angle between Stokes vectors on the Poincare sphere is confirmed to work for all settings of the sample arm fibre. A calibration procedure is proposed to remove the sign ambiguity of the measured orientation and was confirmed experimentally by using the QWP.
引用
收藏
页码:1105 / 1122
页数:18
相关论文
共 50 条
  • [21] Depth-resolved stress field measurement of multilayered system using swept-source polarization-sensitive optical coherence tomography
    Zhang, Xinya
    Chen, Jinlong
    Sun, Cuiru
    OPTICS AND LASERS IN ENGINEERING, 2024, 178
  • [22] Improved optical axis determination accuracy for fiber-based polarization-sensitive optical coherence tomography
    Lu, Zenghai
    Matcher, Stephen J.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVII, 2013, 8571
  • [23] Determination of birefringence and absolute optic axis orientation using polarization-sensitive optical coherence tomography with PM fibers
    Zhang, J
    Guo, SG
    Jung, WG
    Nelson, JS
    Chen, ZP
    OPTICS EXPRESS, 2003, 11 (24): : 3262 - 3270
  • [24] Swept-source optical coherence tomography in optic nerve head avulsion
    Rekik, M.
    Kammoun, S.
    Ayadi, O.
    Trigui, A.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2024, 47 (09):
  • [25] Performance comparison between 8-and 14-bit-depth imaging in polarization-sensitive swept-source optical coherence tomography
    Lu, Zenghai
    Kasaragod, Deepa K.
    Matcher, Stephen J.
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (04): : 794 - 804
  • [26] Polarization-Sensitive Swept-Source Optical Coherence Tomography for Investigating Depth, Birefringence, Depolarization and Orientation of Collagen Structure of Human Cervix Tissue
    Li, Wei
    Narice, Brenda F.
    Anumba, Dilichukwu O.
    Matcher, Stephen J.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXIII, 2019, 10867
  • [27] Visualization of phase retardation of deep posterior eye by polarization-sensitive swept-source optical coherence tomography with 1-μm probe
    Yamanari, Masahiro
    Lim, Yiheng
    Makita, Shuichi
    Yasuno, Yoshiaki
    OPTICS EXPRESS, 2009, 17 (15): : 12385 - 12396
  • [28] Quantifying three-dimensional optic axis using polarization-sensitive optical coherence tomography
    Liu, Chao J.
    Black, Adam J.
    Wang, Hui
    Akkin, Taner
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (07)
  • [29] Processing-based approach for resolving the sample optic axis in endoscopic polarization-sensitive optical coherence tomography
    Adams, David C.
    Suter, Melissa J.
    OPTICS EXPRESS, 2018, 26 (19): : 24917 - 24927
  • [30] Robust reconstruction of local optic axis orientation with fiber-based polarization-sensitive optical coherence tomography
    Li, Qingyun
    Karnowski, Karol
    Noble, Peter B.
    Cairncross, Alvenia
    James, Alan
    Villiger, Martin
    Sampson, David D.
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (11): : 5437 - 5455