Anterior-Segment Swept-Source Ocular Coherence Tomography and Scheimpflug Imaging Agreement for Keratometry and Pupil Measurements in Healthy Eyes

被引:4
|
作者
Perez-Bartolome, Francisco [1 ,2 ]
Rocha-De-Lossada, Carlos [3 ,4 ,5 ]
Sanchez-Gonzalez, Jose-Maria [6 ]
Feu-Basilio, Silvia [2 ]
Torras-Sanvicens, Josep [2 ]
Peraza-Nieves, Jorge [2 ]
机构
[1] Hosp Univ Puerta Hierro, Dept Ophthalmol, Majadahonda 28222, Spain
[2] Univ Barcelona, Hosp Clin Barcelona, Clin Inst Ophthalmol, Dept Ophthalmol, Barcelona 08036, Spain
[3] Vithas Virgen Mar Hosp, Dept Ophthalmol Qvis, Almeria 04120, Spain
[4] Hosp Virgen Las Nieves, Dept Ophthalmol, Granada 18014, Spain
[5] Ceuta Med Ctr, Dept Ophthalmol, Ceuta 51001, Spain
[6] Univ Seville, Pharm Fac, Dept Condensed Matter Phys, Opt Area,Vis Sci Res Grp CIVIUS, Seville 41012, Spain
关键词
anterior-segment swept-source; ocular coherence tomography; Scheimpflug imaging; agreement analysis; pupil measurements; ANGLE KAPPA; IMPLANTATION; ABERRATIONS; THICKNESS; LASIK; OCT;
D O I
10.3390/jcm10245789
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study examines agreement between the devices Anterion(R) and Pentacam HR(R) used for corneal and pupil measurements in healthy eyes. The parameters compared between the two devices were: anterior Km (D), anterior K2 (D), anterior K1 (D), anterior K1 axis (degrees), anterior astigmatism (D), anterior K max (D), posterior Km (D), posterior K2 (D), posterior K1 (D), posterior K1 axis (degrees), posterior astigmatism (D), CCT (mu m), thinnest point thickness (mu m), thinnest point X-coordinate (mm), thinnest point Y-coordinate (mm), pupil diameter (mm), pupil center-corneal vertex distance (mm) (angle kappa), pupil centroid angle (degrees), pupil centroid X-coordinate (mm), and pupil centroid Y-coordinate (mm). The Student's t test for independent samples identified significant differences (p < 0.005) between devices for the measurements anterior and posterior flat K axis, posterior flat K, steep K, and mean K. For these last three measurements, although significant, none of the differences were clinically relevant. Corneal power and thickness measurements except Kf axis showed excellent agreement between Anterion and Pentacam. In a clinical setting we would not recommend the interchangeable use of Pentacam and Anterion for measurement of pupil parameters.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Corneal astigmatism agreement between a swept-source ocular coherence tomography and Scheimpflug–Placido based optical biometers
    Cameron McLintock
    Samir Uprety
    James McKelvie
    International Ophthalmology, 45 (1)
  • [22] Role of swept-source anterior segment optical coherence tomography in imaging pediatric cataract
    Bhardwaj, Anand
    Kaur, Savleen
    Sukhija, Jaspreet
    Gupta, Parul Chawla
    Ram, Jagat
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (05) : 2132 - 2138
  • [23] Repeatability and Agreement of Two Swept-Source Optical Coherence Tomographers for Anterior Segment Parameter Measurements
    Cheng, Shi-Ming
    Zhang, Jia-Sheng
    Li, Tian-tian
    Wu, Ze-tong
    Wang, Po
    Yu, A-Yong
    JOURNAL OF GLAUCOMA, 2022, 31 (07) : 602 - 608
  • [24] Repeatability and agreement of two swept-source optical coherence tomographers and scheimpflug imaging for measurements of corneal curvature
    Shiming Cheng
    Jiasheng Zhang
    Kaijing Zhou
    Tiantian Li
    Junhai Lin
    A.-Yong Yu
    BMC Ophthalmology, 24 (1)
  • [25] Agreement between a new swept-source ocular coherence tomography and a Placido disc-dual Scheimpflug ocular biometric devices
    McLintock, Cameron
    Niyazmand, Hamed
    Seo, Shiney
    Barrett, Graham
    Kumar Nilagiri, Vinay
    Karimian, Sahar
    McKelvie, James
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (02) : 905 - 911
  • [26] Comparison of a New Swept-Source Anterior Segment Optical Coherence Tomography and a Scheimpflug Camera for Measurement of Corneal Curvature
    Zhang, Ting
    Zhou, Yijing
    Young, Charlotte Aimee
    Chen, Aiming
    Jin, Guangming
    Zheng, Danying
    CORNEA, 2020, 39 (07) : 818 - 822
  • [27] Agreement Between Swept-Source Optical Biometry and Scheimpflug-based Topography Measurements of Anterior Segment Parameters
    Ozyol, Pelin
    Ozyol, Erhan
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 169 : 73 - 78
  • [28] Iris Thickness and Severity of Neovascular Glaucoma Determined Using Swept-Source Anterior-segment Optical Coherence Tomography
    Nakakura, Shunsuke
    Kobayashi, Yui
    Matsuya, Kanae
    Terao, Etsuko
    Kiuchi, Yoshiaki
    JOURNAL OF GLAUCOMA, 2018, 27 (05) : 415 - 420
  • [29] Comparison of Anterior Segment Measurements Between Swept-source Optical Coherence Tomography and Schiempflug Coherence Interferometer
    Song, Jiyun
    Na, Kyung Sun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (12): : 1158 - 1167
  • [30] Swept-source anterior segment OCT in dry eye, ocular surface disease and healthy eyes: a repeatability study of quantitative measurements
    Recchioni, Alberto
    Rauz, Saaeha
    Venkataraman, Abinaya
    Dominguez-Vicent, Alberto
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)